Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
2.—(1) Before routine irradiation of a given category of foodstuffs begins at a radiation facility, the locations of the minimum and maximum doses are determined by making dose measurements throughout the product volume. These validation measurements must be carried out a suitable number of times (e.g. 3-5) in order to make allowance for variations in product density or geometry.
(2) Measurements must be repeated whenever the product, its geometry or the irradiation conditions are changed.
(3) During the process, routine dose measurements are carried out in order to ensure that the dose limits are not exceeded. Measurements should be carried out by placing dosimeters at the positions of the maximum or minimum dose, or at a reference position. The dose at the reference position must be quantitatively linked to the maximum and minimum dose. The reference position should be located at a convenient point in or on the product, where dose variations are low.
(4) Routine dose measurements must be carried out on each batch and at regular intervals during production.
(5) In cases where flowing, non-packaged goods are irradiated, the locations of the minimum and maximum doses cannot be determined. In such a case it is preferable to use random dosimeter sampling to ascertain the values of these dose extremes.
(6) Dose measurements should be carried out by using recognised dosimetry systems, and the measurements should be traceable to primary standards.
(7) During irradiation, certain facility parameters must be controlled and continuously recorded. For radionuclide facilities the parameters include product transport speed or time spent in the radiation zone and positive indication for correct position of the source. For accelerator facilities, the parameters include product transport speed and energy level, electron current and scanner width of the facility.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: