xmlns:atom="http://www.w3.org/2005/Atom" xmlns:atom="http://www.w3.org/2005/Atom"
1.0.Regulation (EC) No 1272/2008 “ Regulation (EC) No 1272/2008 ”...
2.1.1.The filled aerosol dispenser must be such that, under normal...
2.1.2.The valve must enable the aerosol dispenser to be virtually...
2.1.3.There must be no possibility that the mechanical resistance of...
3.1.2.The pressure at 50°C in the aerosol dispenser must not...
5.1.Plastic aerosol dispensers which may splinter on bursting shall be...
5.2.Plastic aerosol dispensers which cannot splinter on bursting shall be...
6.1.Test requirements to be guaranteed by the person responsible for marketing the aerosol dispenser
6.1.1.1.Metal, glass or plastic aerosol dispensers must be able to...
6.1.1.2.Metal containers showing assymetrical or major distortions or other similar...
6.1.4.1.Aerosol dispensers shall be subject to one of the following...
6.1.4.2.For aerosol dispensers the contents of which undergo a physical...
6.1.4.3.In case of test methods according to points 6.1.4.1(b) and...
6.3.1.1.1.This test standard describes the method to determine the ignition...
6.3.1.1.2.This test is applicable to aerosol products with a spray...
6.3.1.2.1.The following apparatus is required: Water bath maintained at 20°C...
6.3.1.3.1.1.Before testing, each aerosol dispenser shall be conditioned and then...
6.3.1.3.1.2.The instructions of use shall be strictly followed, including whether...
6.3.1.3.1.3.The test shall be carried out in a draught-free environment...
6.3.1.3.1.5.During the test, the can shall be positioned as indicated...
6.3.1.3.1.6.The following procedure requires testing the spray at intervals of...
6.3.1.3.2.1.All experiments shall be performed in a fume hood in...
6.3.1.3.2.2.The cans with a 10-12 % nominal fill level shall...
6.3.1.3.2.3.When the test in the position in which the dispenser...
6.3.1.4.1.All the results shall be recorded. Table 6.3.1.1 below shows...
6.3.2.2.1.The following apparatus is required: Chronometer (stopwatch) accurate to ±...
6.3.2.2.2.1.A cylindrical vessel approximately 200 dm 3 volume, approximately 600mm...
6.3.2.2.2.2.Usually, the product leaves the aerosol can at an angle...
6.3.2.3.1.1.Before testing, each aerosol dispenser shall be conditioned and then...
6.3.2.3.1.2.The instructions of use shall be strictly followed, including whether...
6.3.2.3.1.3.The tests shall be carried out in a draught-free environment...
6.3.2.4.1.A test report containing the following information shall be drawn...
6.3.2.4.2.The time equivalent (t eq ) needed to achieve ignition...
6.3.2.4.3.The deflagration density (D def ) needed to achieve ignition...
6.3.3.1.1.This test standard describes the method to determine the flammability...
6.3.3.2.1.The following apparatus is required: Graduated scale, support and clamp...
6.3.3.2.2.The watch-glass is placed on a fire-resistant surface within a...
6.3.3.3.1.1.Before testing, each aerosol dispenser shall be conditioned and then...
6.3.3.3.1.2.The instructions of use shall be strictly followed, including whether...
6.3.3.3.1.3.The tests shall be carried out in a draught-free environment...
6.3.3.4.1.A test report containing the following information shall be drawn...