Lighting of en-route obstaclesU.K.
219.—(1) The person in charge of an en-route obstacle must ensure that it is fitted with medium intensity steady red lights positioned as close as possible to the top of the obstacle and at intermediate levels spaced so far as practicable equally between the top lights and ground level with an interval of not more than 52 metres.
(2) The person in charge of an en-route obstacle must, subject to paragraph (3), ensure that by night the lights required to be fitted by this article are displayed.
(3) In the event of the failure of any light which is required by this article to be displayed by night the person in charge must repair or replace the light as soon as reasonably practicable.
(4) At each level on the obstacle where lights are required to be fitted, sufficient lights must be fitted and arranged so as to show when displayed in all directions.
(5) In any particular case the CAA may direct that an en-route obstacle must be fitted with and must display such additional lights in such positions and at such times as it may specify.
(6) A permission may be granted for the purposes of this article for a particular case or class of cases or generally.
(7) This article does not apply to any en-route obstacle for which the CAA has granted a permission to the person in charge permitting that person not to fit and display lights in accordance with this article.
(8) In this article, an ‘en-route obstacle’ means any building, structure or erection, the height of which is 150 metres or more above ground level, but it does not include a building, structure or erection—
(a)which is in the vicinity of a licensed aerodrome; and
(b)to which section 47 of the Civil Aviation Act 1982 M1 (warning of presence of obstructions near licensed aerodromes) applies.
Marginal Citations