PART 7USE OF ULTRA-WIDEBAND EQUIPMENT FOR BUILDING MATERIAL ANALYSIS

Terms, provisions and limitationsI130

1

The exemption provided for in regulation 29 shall apply to ultra-wideband equipment which is a building material analysis device and which complies with the requirements of paragraphs (2) to (4) of this regulation.

2

The ultra-wideband equipment must—

a

only have the transmitter turned on if manually operated with a non-locking switch;

b

be used in close proximity to the material being analysed with the emissions being directed into the direction of the object of the analysis; and

c

switch off automatically after ten seconds without any movement.

3

The ultra-wideband equipment must not cause or contribute to undue interference to other users of the electromagnetic spectrum.

4

The ultra-wideband equipment must only emit signals F1... which—

a

are kept to a minimum; and

b

if the equipment were to be placed on a representative wall F2(as defined within harmonised standard ETSI EM 302 065-4)F3 would be in accordance with the condition in regulation 31.