Part 2Obligations of economic operators
All economic operators
Safe connection of electrical equipment intended for use in the United KingdomE235
1
This regulation applies to electrical equipment intended for domestic use in the United Kingdom and made available by an economic operator for that purpose.
2
Where the electrical equipment is a plug in device intended to be connected, without the use of a mains lead or plug, directly to the United Kingdom public electricity supply via a socket outlet conforming to BS 1363, the economic operator must ensure that the plug in device is compatible with socket outlets conforming to BS 1363.
3
Where the electrical equipment has a flexible lead and plug assembly and is intended to be connected to the United Kingdom public electricity supply by means of a socket outlet conforming to BS 1363, the economic operator must ensure that that plug assembly—
a
is a correctly fitted standard plug; or
b
is—
i
a correctly fitted non-UK plug, conforming to the safety provisions of IEC 884-1 and correctly fitted with a compatible conversion plug; and
ii
fitted with a fuse link which conforms to BS 1362 and which is rated in accordance with the electrical equipment manufacturer's instructions.
4
In this regulation, “socket”, “BS 1363”, “standard plug”, “non-UK plug”, “IEC 884-1”, “conversion plug”, “fuse link” and “BS 1362” have the meanings given in the Plugs and Sockets etc. (Safety) Regulations 1994 M1.
Safe connection of electrical equipment intended for use in F1Northern IrelandE135
1
This regulation applies to electrical equipment intended for domestic use in F2Northern Ireland and made available by an economic operator for that purpose.
2
Where the electrical equipment is a plug in device intended to be connected, without the use of a mains lead or plug, directly to the United Kingdom public electricity supply via a socket outlet conforming to BS 1363, the economic operator must ensure that the plug in device is compatible with socket outlets conforming to BS 1363.
3
Where the electrical equipment has a flexible lead and plug assembly and is intended to be connected to the United Kingdom public electricity supply by means of a socket outlet conforming to BS 1363, the economic operator must ensure that that plug assembly—
a
is a correctly fitted standard plug; or
b
is—
i
a correctly fitted non-UK plug, conforming to the safety provisions of IEC 884-1 and correctly fitted with a compatible conversion plug; and
ii
fitted with a fuse link which conforms to BS 1362 and which is rated in accordance with the electrical equipment manufacturer's instructions.
4
In this regulation, “socket”, “BS 1363”, “standard plug”, “non-UK plug”, “IEC 884-1”, “conversion plug”, “fuse link” and “BS 1362” have the meanings given in the Plugs and Sockets etc. (Safety) Regulations 1994 F3.