F1SCHEDULE 6(Annex I to the Directive)

Annotations:

ESSENTIAL REQUIREMENTS

Metrological requirements

2

The following accuracy classes have been defined—

a

I special

b

II high

c

III medium

d

IIII ordinary

The specifications of these classes are given in Table 1.

Table 1

Accuracy classes

Class

Verification scale interval (e)

Minimum capacity (Min)

Number of verification scale intervals n = ((Max)/(e))

minimum value

minimum value

maximum value

I

0,001 g ≤ e

100 e

50 000

II

0,001 g ≤ e ≤ 0,05 g

20 e

100

100 000

0,1 g ≤ e

50 e

5 000

100 000

III

0,1 g ≤ e ≤ 2 g

20 e

100

10 000

5 g ≤ e

20 e

500

10 000

IIII

5 g ≤ e

10 e

100

1 000