3.3.3. The partial weighing ranges are classified according to Table 2. All partial weighing ranges shall fall into the same accuracy class, that class being the instrument's accuracy class.E+W+S
Multi-level instruments | ||||
---|---|---|---|---|
i = 1, 2, …r, i = partial weighing range number, r = the total number of partial weighing ranges | ||||
Class | Verification scale interval (e) | Minimum capacity (Min) | Number of verification scale intervals | |
Minimum value | Minimum value F2 n = ((Maxi) / (e(i+1))) | Maximum value n = ((Maxi) / (ei)) | ||
I | 0,001 g ≤ ei | 100 e1 | 50 000 | |
II | 0,001 g ≤ ei ≤ 0,05 g | 20 e1 | 5 000 | 100 000 |
0,1 g ≤ ei | 50 e1 | 5 000 | 100 000 | |
III | 0,1 g ≤ ei | 20 e1 | 500 | 10 000 |
IIII | 5g ≤ ei | 10 e1 | 50 | 1 000] |