Regulations 2(1) and 39(1)
1. The essential requirements and conformity assessment procedure applicable to measuring instruments are as set out in this Schedule.
2.—(1) The essential requirements relating to water meters intended for the measurement of volumes of clean, cold or heated water in residential, commercial and light industrial use are—
(a)the requirements set out in Annex I to the Directive; and
(b)the specific requirements of Annex III to the Directive subject to the modification specified in sub-paragraph (2).
(2) The modification referred to in sub-paragraph (1)(b) is that point 10 of the specific requirements in Annex III is to be read as follows—
10. The requirements under points 1, 2 and 3 are determined by the utility or the person legally designated for installing the meter, so that the meter is appropriate for the accurate measurement of consumption that is foreseen or foreseeable.”
(3) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to water meters of the kind referred to in sub-paragraph (1) are—
(a)B and F;
(b)B and D; or
(c)H1.
3.—(1) The essential requirements relating to gas meters intended for residential, commercial and light industrial use are—
(a)the requirements of Annex I to the Directive; and
(b)the specific requirements set out in Part I of Annex IV to the Directive subject to the modification in sub-paragraph (2).
(2) The modification referred to in sub-paragraph (1)(b) is that point 10 of the specific requirements in Annex IV is to be read as follows—
10.—(a) The measurement of residential use must be performed by means of any Class 1.5 gas meter, or by Class 1.0 gas meters which have a Qmax/Qmin ratio equal to or greater than 150.
(b)Measurement of commercial or light industrial use must be performed by any Class 1.0 or Class 1.5 gas meter.
(c)The person responsible for installing a gas meter must have regard to the requirements under Points 1.2 and 1.3 of Part I of Annex IV and must ensure that the gas meter is appropriate for the accurate measurement of consumption that is foreseen or foreseeable.”
(3) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to gas meters are—
(a)B and F;
(b)B and D; or
(c)H1.
4.—(1) In this paragraph “conversion device” means a device fitted to a gas meter that automatically converts the quantity measured at metering conditions into a quantity at the specified conditions to which the quantity of fluid is converted.
(2) The essential requirements relating to conversion devices intended for residential, commercial and light industrial use are—
(a)the requirements of Annex I to the Directive;
(b)the specific requirements set out in Part II of Annex IV.
(3) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to conversion devices are—
(a)B and F;
(b)B and D; or
(c)H1.
5.—(1) The essential requirements in relation to active electrical energy meters intended for residential, commercial and light industrial use are—
(a)the requirements of Annex I of the Directive; and
(b)the specific requirements in Annex V subject to the modification in sub-paragraph (2).
(2) The modification referred to in sub-paragraph (1)(b) is that point 7 of the specific requirements in Annex V is to be read as follows—
7.—(a) Subject to sub-paragraph (2), measurement may be performed by means of any active electrical energy meter provided that the temperature range to which an active electrical energy meter is exposed is not wider that the range specified by the manufacturer in relation to that active electrical energy meter in accordance with Point 1.3.1 and Table 1 in Annex 1 to the Directive.
(b)Class A active electrical energy meters may not be used when operating outside the temperature range of an upper temperature limit of 30°C to a lower temperature limit of 5 °C.
(c)The person responsible for installing the active electrical energy meter must determine the correct current range and assess the climatic environment.”
(3) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to active electrical meters are—
(a)B and F;
(b)B and D; or
(c)H1.
6.—(1) The essential requirements in relation to thermal energy meters are—
(a)the requirements of Annex I of the Directive; and
(b)the requirements of Annex VI.
(2) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to thermal energy meters are—
(a)B and F;
(b)B and D; or
(c)H1.
7.—(1) The essential requirements in relation to non-water liquid measuring systems are——
(a)the requirements of Annex I of the Directive; and
(b)the requirements of Annex VII.
(2) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to non-water liquid measuring systems are—
(a)B and F;
(b)B and D;
(c)H1; or
(d)G.
8.—(1) The essential requirements in relation to automatic weighing instruments are—
(a)in relation to automatic catchweighers—
(i)the requirements of Annex I of the Directive; and
(ii)the specific requirements in Chapter I and II of Annex VIII;
(b)in relation to automatic gravimetric filling instruments—
(i)the requirements of Annex I of the Directive; and
(ii)the specific requirements in Chapter I and Chapter III of Annex VIII;
(c)in relation to discontinuous totalisers—
(i)the requirements of Annex I of the Directive; and
(ii)the specific requirements in Chapter I and Chapter IV of Annex VIII;
(d)The essential requirements in relation to beltweighers are—
(i)the requirements of Annex I of the Directive; and
(ii)the specific requirements in Chapters I and V of Annex VIII; and
(e)The essential requirements in relation to automatic rail weighbridges are—
(i)the requirements of Annex I of the Directive; and
(ii)the specific requirements in Chapters I and VI in Annex VIII.
(2) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to automatic weighing instruments are—
(a)for mechanical systems—
(i)B and D;
(ii)B and E;
(iii)B and F;
(iv)D1;
(v)F1;
(vi)G; or
(vii)H1;
(b)for electromechanical instruments—
(i)B and D;
(ii)B and E;
(iii)B and F;
(iv)G; or
(v)H1; and
(c)for electronic systems or systems containing software—
(i)B and D;
(ii)B and F;
(iii)G; or
(iv)H1.
9.—(1) The essential requirements in relation to taximeters are—
(a)the requirements of Annex 1 of the Directive; and
(b)the specific requirements in Annex IX.
(2) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to taximeters are—
(a)B and F;
(b)B and D; or
(c)H1.
10.—(1) The essential requirements in relation to material measures of length are—
(a)the requirements of Annex I of the Directive; and
(b)the specific requirements in Chapter I of Annex X.
(2) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to material measures of length are—
(a)F1;
(b)D1;
(c)B and D;
(d)G; or
(e)H.
11.—(1) The essential requirements in relation to capacity serving measures are—
(a)the requirements of Annex I of the Directive; and
(b)the specific requirements in Chapter II of Annex X.
(2) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to capacity serving measures are—
(a)A2;
(b)D1;
(c)E1;
(d)F1;
(e)B and D;
(f)B and E; or
(g)H.
12.—(1) The essential requirements in relation to dimensional measuring instruments are—
(a)the requirements of Annex I of the Directive; and
(b)the specific requirements in Annex XI.
(2) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to dimensional measuring instruments are—
(a)for mechanical or electromechanical instruments—
(i)D1;
(ii)E1;
(iii)F1;
(iv)H;
(v)H1;
(vi)G;
(vii)B and D;
(viii)B and E;
(ix)B and F;
(b)for electronic instruments or instruments containing software—
(i)B and D;
(ii)B and F;
(iii)G; or
(iv)H1.
13.—(1) The essential requirements in relation to exhaust gas analysers are—
(a)the requirements of Annex I of the Directive; and
(b)the specific requirements in Annex XII.
(2) The conformity assessment procedures specified in the modules in Annex II to the Directive applicable to exhaust gas analysers are—
(a)B and D;
(b)B and F; or
(c)H1.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: