[F18.1.  The MPEs due to influence factors shall be as specified in Table 6.E+W+S

Table 6

Load (m) in totalisation scale intervals (dt)MPE
0 < m ≤ 500± 0.5 dt
500 < m ≤ 2,000± 1.0 dt
2,000 < m ≤ 10,000± 1.5 dt]