SCHEDULE 6U.K.IN SERVICE REQUIREMENTS FOR CERTAIN REGULATED MEASURING INSTRUMENTS IN GREAT BRITAIN

PART 5U.K.AUTOMATIC CATCHWEIGHERS

Maximum permissible errorU.K.

16.—(1) The maximum permissible error for an automatic catchweigher in automatic operation is to be determined in accordance with the following table—

Net Load (m) in verification scale intervals (e)Maximum permissible error
Y(I)Y(II)Y(a)Y(b)
0 ˂ m ≤ 50 0000 ˂ m ≤ 5 0000 ˂ m ≤ 5000 ˂ m ≤ 50±2e
50 000 ˂ m ≤ 200 0005 000 ˂ m ≤ 20 000500 ˂ m ≤ 20 200050 ˂ m ≤ 200±3e
200 000 ˂ m20 000 ˂ m≤ 100 0002 000 ˂ m ≤ 10 000200 ˂ m ≤ 20 1 000±4e

(2) The maximum permissible error for an automatic catchweigher in non-automatic operation is to be determined in accordance with the following table—

Net Load (m) in verification scale intervals (e)Maximum permissible error
Y(I)Y(II)Y(a)Y(b)
0 ˂ m ≤ 50 0000 ˂ m ≤ 5 0000 ˂ m ≤ 5000 ˂ m ≤ 50±1e
50 000 ˂ m ≤ 200 0005 000 ˂ m ≤ 20 000500 ˂ m ≤ 20 200050 ˂ m ≤ 200±2e
200 000 ˂ m20 000 ˂ m≤ 100 0002 000 ˂ m ≤ 10 000200 ˂ m ≤ 20 1 000±3e