16.—(1) The maximum permissible error for an automatic catchweigher in automatic operation is to be determined in accordance with the following table—
Net Load (m) in verification scale intervals (e) | Maximum permissible error | |||
---|---|---|---|---|
Y(I) | Y(II) | Y(a) | Y(b) | |
0 ˂ m ≤ 50 000 | 0 ˂ m ≤ 5 000 | 0 ˂ m ≤ 500 | 0 ˂ m ≤ 50 | ±2e |
50 000 ˂ m ≤ 200 000 | 5 000 ˂ m ≤ 20 000 | 500 ˂ m ≤ 20 2000 | 50 ˂ m ≤ 200 | ±3e |
200 000 ˂ m | 20 000 ˂ m≤ 100 000 | 2 000 ˂ m ≤ 10 000 | 200 ˂ m ≤ 20 1 000 | ±4e |
(2) The maximum permissible error for an automatic catchweigher in non-automatic operation is to be determined in accordance with the following table—
Net Load (m) in verification scale intervals (e) | Maximum permissible error | |||
---|---|---|---|---|
Y(I) | Y(II) | Y(a) | Y(b) | |
0 ˂ m ≤ 50 000 | 0 ˂ m ≤ 5 000 | 0 ˂ m ≤ 500 | 0 ˂ m ≤ 50 | ±1e |
50 000 ˂ m ≤ 200 000 | 5 000 ˂ m ≤ 20 000 | 500 ˂ m ≤ 20 2000 | 50 ˂ m ≤ 200 | ±2e |
200 000 ˂ m | 20 000 ˂ m≤ 100 000 | 2 000 ˂ m ≤ 10 000 | 200 ˂ m ≤ 20 1 000 | ±3e |