Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
14. In this Part references to an automatic catchweigher are to accuracy classes Y(I), Y(II), Y(a) and Y(b) as defined in [F1Schedule 1G].
Textual Amendments
F1Words in Sch. 6 para. 14 substituted (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 27 para. 53 (with Sch. 27 para. 50(a)) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)
15.—(1) No person shall use for trade an automatic catchweigher unless—
(a)it is compliant with the essential requirements other than the provisions relating to maximum permissible errors;
(b)in the case of an automatic catchweigher of accuracy class Y(I), Y(II), Y(a) or Y(b) it operates within the maximum permissible errors in paragraph 16;
(c)the requirements of paragraphs 17 to 20 are complied with; and
(d)it has been erected and installed in accordance with the requirements of paragraph 21.
16.—(1) The maximum permissible error for an automatic catchweigher in automatic operation is to be determined in accordance with the following table—
Net Load (m) in verification scale intervals (e) | Maximum permissible error | |||
---|---|---|---|---|
Y(I) | Y(II) | Y(a) | Y(b) | |
0 ˂ m ≤ 50 000 | 0 ˂ m ≤ 5 000 | 0 ˂ m ≤ 500 | 0 ˂ m ≤ 50 | ±2e |
50 000 ˂ m ≤ 200 000 | 5 000 ˂ m ≤ 20 000 | 500 ˂ m ≤ 20 2000 | 50 ˂ m ≤ 200 | ±3e |
200 000 ˂ m | 20 000 ˂ m≤ 100 000 | 2 000 ˂ m ≤ 10 000 | 200 ˂ m ≤ 20 1 000 | ±4e |
(2) The maximum permissible error for an automatic catchweigher in non-automatic operation is to be determined in accordance with the following table—
Net Load (m) in verification scale intervals (e) | Maximum permissible error | |||
---|---|---|---|---|
Y(I) | Y(II) | Y(a) | Y(b) | |
0 ˂ m ≤ 50 000 | 0 ˂ m ≤ 5 000 | 0 ˂ m ≤ 500 | 0 ˂ m ≤ 50 | ±1e |
50 000 ˂ m ≤ 200 000 | 5 000 ˂ m ≤ 20 000 | 500 ˂ m ≤ 20 2000 | 50 ˂ m ≤ 200 | ±2e |
200 000 ˂ m | 20 000 ˂ m≤ 100 000 | 2 000 ˂ m ≤ 10 000 | 200 ˂ m ≤ 20 1 000 | ±3e |
17. An automatic catchweigher marked with a measurement range may be used for trade for determining the difference between two weights where both items fall within the measurement range.
18. Where an automatic catchweigher is marked with a measurement range, no person may use the catchweigher for trade for determining a weight outside that range in relation—U.K.
(a)to, or to articles made from, gold, silver or other precious metals, including gold or silver thread or fringe;
(b)to precious stones or pearls; or
(c)to drugs or other pharmaceutical products.
19. No person may use for trade an automatic catchweigher other than catchweigher of accuracy class Y(I) or Y(II) in any transaction—U.K.
(a)in, or in articles made from gold silver or other precious metals, including gold or silver thread or fringe; or
(b)in precious stones or pearls.
20.—(1) Where an automatic catchweigher is marked with a temperature range, it must not be used for trade in temperatures outside that range.U.K.
(2) Where an automatic catchweigher bears a mark which signifies the manner and purpose of use, it must not be used for trade in a manner or for a purpose which does not accord with that marking.
(3) An automatic catchweigher of accuracy class Y(b) must only be used for weighing ballast or waste.
(4) An automatic catchweigher must not be used for trade in circumstances—
(a)in which it may be prevented from operating consistently or accurately; or
(b)which are likely prematurely to degrade its metrological characteristics.
(5) For the purposes of paragraph (3), “waste” means any substance that its holder discards, or intends or is required to discard, including any waste disposed of for reprocessing or recycling purposes.
21.—(1) Every automatic catchweigher must be positioned so as to facilitate cleaning and testing.
(2) The installation of an automatic catchweigher must be so designed that an automatic weighing operation will be the same for testing as for use for a transaction.
(3) If an automatic catchweigher has any special equipment for its control which is not a permanent fixture of the catchweigher, it must be kept in the vicinity of the catchweigher.
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: