The Control of Electromagnetic Fields at Work Regulations 2016

Action levels – non-thermal effects

Table AL5 – ALs for contact currents
Frequency of electromagnetic field in which an object is presentContact current ALs (IC) [mA]
up to 2.5 kHz1.0
2.5 ≤ f < 100 kHz0.4 f
100 ≤ f ≤10,000 kHz40
Notes

1.  “f” is the frequency expressed in kHz.

2.  The ALs are root mean square values.

3.  The ALs represent the maximum steady state current created during a continuous contact with an object in an electromagnetic field.

Table AL6 – ALs for static magnetic fields
Potential indirect effectMagnetic flux density ALs (B0) [mT]
Interference with active implanted medical devices0.5
Attraction and projectile risk in the fringe field of high field strength sources (> 100 mT)3
Note

The AL for interference with active implanted medical devices represents the maximum field value at any place where an employee may be working.