- Latest available (Revised)
- Original (As made)
This is the original version (as it was originally made). This item of legislation is currently only available in its original format.
2.—(1) The EEI is determined as follows.
(2) For all refrigerating appliances with a direct sales function, the EEI, expressed in per cent and rounded to the first decimal place, is the ratio of the AE (in kWh/a) and the reference SAE (in kWh/a) and is calculated as—
EEI = AE/SAE.
(3) For the purposes of sub-paragraph (2) the AE, expressed in kWh/a and rounded to two decimal places, is calculated as follows—
AE = 365 × Edaily;
where Edaily is the energy consumption of the refrigerating appliance with a direct sales function over 24 hours, expressed in kWh/24h and rounded to three decimal places.
(4) For the purposes of sub-paragraph (2) the SAE, expressed in kWh/a and rounded to two decimal places, is calculated as follows—
(a)for refrigerating appliances with a direct sales function where all compartments have the same temperature class, and for refrigerated vending machines, the SAE is calculated as—
SAE = 365 × P × (M + N × Y) × C;
(b)for all other refrigerating appliances with a direct sales function, the SAE is calculated as—
(5) For the purposes of sub-paragraph (4)—
(a)c is the index number for a compartment type ranging from 1 to n, with n being the total number of compartment types;
(b)the values of M and N are as set out in Table 6;
(c)the values of C (the temperature coefficient) are set out in Table 7; for any appliance not listed in Table 7, the value of C is 1;
(d)coefficient Y is calculated as follows—
(i)for beverage coolers, Yc is the equivalent volume of the compartments of the beverage cooler with target temperature Tc, (Veqc), calculated as follows—
Yc = Veqc = GrossVolumec × ((25 - Tc)/20) × CC;
where—
Tc is the average compartment temperature and CC is the climate class factor;
the values for Tc are as set out in Table 8;
the values for CC are as set out in Table 9;
(ii)for ice-cream freezers, Yc is the equivalent volume of the compartments of the ice-cream freezer with target temperature Tc, (Veqc), calculated as follows—
Yc = Veqc = NetVolumec × ((12 - Tc)/30) × CC; where—
Tc is the average compartment temperature and CC is the climate class factor;
the values for Tc are as set out in Table 10;
the values for CC are as set out in Table 11;
(iii)for refrigerated vending machines, Y is the net volume of the refrigerated vending machine, which is the sum of the volumes of all compartments within which the products directly available for vending are contained and the volume through which the products pass during the dispensing process, expressed in litres (L) and rounded to the nearest integer;
(iv)for all other refrigerating appliances with direct sales function, Yc is the sum of the TDA of all compartments of the same temperature class of the refrigerating appliance with a direct sales function, expressed in square meters (m2), and rounded to two decimal places;
(e)the values of P are set out in Table 12.
Category | Value for M | Value for N |
---|---|---|
Beverage coolers | 2.1 | 0.006 |
Ice-cream freezers | 2.0 | 0.009 |
Refrigerated vending machines | 4.1 | 0.004 |
Gelato-scooping cabinets | 25.0 | 30.4 |
Vertical and combined supermarket refrigerator cabinets | 9.1 | 9.1 |
Horizontal supermarket refrigerator cabinets | 3.7 | 3.5 |
Vertical and combined supermarket freezer cabinets | 7.5 | 19.3 |
Horizontal supermarket freezer cabinets | 4.0 | 10.3 |
Roll-in cabinets (until 31 August 2023) | 9.2 | 11.6 |
Roll-in cabinets (from 1 September 2023) | 9.1 | 9.1 |
Part 1 – supermarket and gelato cabinets
Category | Temperature class | Highest temperature of warmest M-package (°C) | Lowest temperature of coldest M-package (°C) | Highest minimum temperature of all M-packages (°C) | Value for C |
---|---|---|---|---|---|
Vertical and combined supermarket refrigerator cabinets | M2 | ≤ +7 | ≥ -1 | N/A | 1.00 |
H1 and H2 | ≤ +10 | ≥ -1 | N/A | 0.82 | |
M1 | ≤ +5 | ≥ -1 | N/A | 1.15 | |
Horizontal supermarket refrigerator cabinets | M2 | ≤ +7 | ≥ -1 | N/A | 1.00 |
H1 and H2 | ≤ +10 | ≥ -1 | N/A | 0.92 | |
M1 | ≤ +5 | ≥ -1 | N/A | 1.08 | |
Vertical and combined supermarket freezer cabinets | L1 | ≤ -15 | N/A | ≤ -18 | 1.00 |
L2 | ≤ -12 | N/A | ≤ -18 | 0.9 | |
L3 | ≤ -12 | N/A | ≤ -15 | 0.9 | |
Horizontal supermarket freezer cabinets | L1 | ≤ -15 | N/A | ≤ -18 | 1.00 |
L2 | ≤ -12 | N/A | ≤ -18 | 0.92 | |
L3 | ≤ -12 | N/A | ≤ -15 | 0.92 | |
Vertical and combined refrigerator supermarket cabinets | M0 | ≤ + 4 | ≥ - 1 | N/A | 1.30 |
Horizontal refrigerator supermarket cabinets | M0 | ≤ + 4 | ≥ - 1 | N/A | 1.13 |
Gelato-scooping cabinets | G1 | -10 | -14 | N/A | 1.00 |
G2 | -10 | -16 | N/A | 1.00 | |
G3 | -10 | -18 | N/A | 1.00 | |
L1 | -15 | N/A | -18 | 1.00 | |
L2 | -12 | N/A | -18 | 1.00 | |
L3 | -12 | N/A | -15 | 1.00 | |
S (special classification) | 1.00 |
Part 2 – Refrigerated vending machines
Temperature class | Maximum measured product temperature (Tv) (°C) | Value for C |
---|---|---|
Category 1 | 7 | 1+(12-Tv)/25 |
Category 2 | 12 | |
Category 3 | 3 | |
Category 4 | (Tv1+Tv2)/2 | |
Category 6 | (Tv1+Tv2)/2 |
(6) For the purposes of Table 7—
(a)“N/A” means “not applicable”;
(b)for multi-temperature vending machines, TV is the average of TV1 (the maximum measured product temperature in the warmest compartment) and TV2 (the maximum measured product temperature in the coldest compartment), rounded to one decimal;
(c)the categories of temperature class in Part 2 are—
category 1: refrigerated closed fronted can and bottle machines where the products are held in stacks;
category 2: refrigerated glass fronted can and bottle, confectionery & snack machines;
category 3: refrigerated glass fronted machines entirely for perishable foodstuffs;
category 4: refrigerated multi-temperature glass fronted machines;
category 6: combination machines consisting of different categories of machine in the same housing and powered by one chiller.
Temperature class | Tc (°C) |
---|---|
K1 | +3.5 |
K2 | +2.5 |
K3 | -1.0 |
K4 | +5.0 |
Warmest ambient temperature (°C) | Ambient relative humidity (per cent) | CC |
---|---|---|
+25 | 60 | 1.00 |
+32 | 65 | 1.05 |
+40 | 75 | 1.10 |
Temperature class | Temperature class | Tc (°C) |
---|---|---|
Warmest M-package temperature colder or equal to in all tests (except lid opening test) (°C) | Warmest M-package maximum temperature rise allowed during the lid opening test (°C) | |
-18 | 2 | -18.0 |
-7 | 2 | -7.0 |
Minimum ambient temperature (°C) | Minimum ambient relative humidity (per cent) | Maximum ambient temperature (°C) | Maximum ambient relative humidity (per cent) | CC | |
---|---|---|---|---|---|
Ice-cream freezer with transparent lid | 16 | 80 | 30 | 55 | 1.00 |
35 | 75 | 1.10 | |||
40 | 40 | 1.20 | |||
Ice-cream freezer with non-transparent lid | 16 | 80 | 30 | 55 | 1.00 |
35 | 75 | 1.04 | |||
40 | 40 | 1.10 |
Cabinet type | P |
---|---|
Integral supermarket cabinets | 1.10 |
Other refrigerating appliances with a direct sales function | 1.00 |
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Schedules you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: