The Private Water Supplies (Wales) Regulations 2017

Regulations 12 and 13

SCHEDULE 3E+WMonitoring of radioactive substances

RadonE+W

1.—(1) In relation to the radon parameter in the radioactive substances parameters table, a local authority—

(a)must ensure that a representative survey is carried out in accordance with sub-paragraph (2) to determine the likelihood of a private water supply failing to comply with the relevant parametric concentration or value specified in the radioactive substances parameters table; and

(b)must carry out monitoring where there is reason to believe, on the basis of the results of the representative surveys or other reliable information, including any risk assessment carried out in accordance with regulation 6, that the parametric value for the radon parameter laid down in the radioactive substances parameters table might be exceeded.

(2) A representative survey must be designed in such a way—

(a)as to be capable of determining the scale and nature of likely exposure to radon in water intended for human consumption originating from different types of groundwater sources and wells in different geological areas; and

(b)that underlying parameters, especially the geology and hydrology of the area, radioactivity of rock or soil, and well type, can be identified and used to direct further action to areas of likely high exposure to radon.

Commencement Information

I1Sch. 3 para. 1 in force at 20.11.2017, see reg. 1

TritiumE+W

2.—(1) In relation to the tritium parameter in the radioactive substances parameters table, a local authority—

(a)must carry out monitoring where an anthropogenic source of tritium or other artificial radionuclides is present within the catchment area and it cannot be shown on the basis of other surveillance programmes or investigations, including any risk assessment carried out in accordance with regulation 6, that the level of tritium is below the parametric value listed in the radioactive substances parameters table; and

(b)must carry out an investigation of the presence of other artificial radionuclides if the concentration of tritium exceeds the parametric value listed in the radioactive substances parameters table.

(2) Where monitoring is required by sub-paragraph (1)—

(a)it must be carried out at the frequencies as set out for monitoring for Group B parameters in Table 3 in Part 2 of Schedule 2; or

(b)it must (in the case of a private water supply falling within the scope of regulation 11(1)) be carried out at least every 5 years or more frequently if the risk assessment referred to under sub-paragraph (1)(a) shows this to be necessary.

Commencement Information

I2Sch. 3 para. 2 in force at 20.11.2017, see reg. 1

Indicative DoseE+W

3.—(1) In relation to the indicative dose parameter in the radioactive substances parameters table, a local authority must carry out monitoring where a source of artificial radioactivity or elevated natural radioactivity is present and it cannot be shown on the basis of other surveillance programmes or investigations, including any risk assessment carried out in accordance with regulation 6, that the level of indicative dose is below the parametric value listed in the radioactive substances parameters table.

(2) Where monitoring is required by sub-paragraph (1) in relation to artificial radionuclides—

(a)it must be carried out at the frequencies as set out for monitoring for Group B parameters in Table 3 in Part 2 of Schedule 2; or

(b)it must (in the case of a private water supply falling within the scope of regulation 11(1)) be carried out at least every 5 years or more frequently if the risk assessment shows this to be necessary.

(3) Where monitoring is required by sub-paragraph (1) in relation to a source of elevated natural radioactivity—

(a)the local authority—

(i)may decide the frequency of monitoring in its area depending on the screening strategy adopted by the authority; and

(ii)must notify the Welsh Ministers in writing of its decision under sub-paragraph (i); and

(b)the frequency of monitoring decided under paragraph (a)(i) may vary from a single check measurement to the frequencies as set out for monitoring for Group B parameters in Table 3 in Part 2 of Schedule 2.

(4) Where a local authority decides under sub-paragraph (3) that a single check measurement for natural radioactivity is appropriate, the local authority must carry out a further check if any change occurs in relation to the private water supply which is likely to influence the concentrations of radionuclides in the supply.

Commencement Information

I3Sch. 3 para. 3 in force at 20.11.2017, see reg. 1

Water treatmentE+W

4.  Where treatment to reduce the level of radionuclides in a private water supply has been undertaken, the local authority must monitor the supply for total indicative dose, radon and tritium in accordance with the provisions of this Part and the frequencies as set out for monitoring for Group B parameters in Table 3 in Part 2 of Schedule 2 to verify the continued efficacy of that treatment.

Commencement Information

I4Sch. 3 para. 4 in force at 20.11.2017, see reg. 1

AveragingE+W

5.  Where a parametric value in the radioactive substances parameters table is exceeded in relation to a particular sample taken by a local authority, the Welsh Ministers must specify, by notice in writing to the local authority, the extent of resampling necessary to ensure that the measured values are representative of an average activity concentration for a full year.

Commencement Information

I5Sch. 3 para. 5 in force at 20.11.2017, see reg. 1