Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

Regulations 13 and 14

SCHEDULE 4E+WSampling and analysis

PART 1E+WGeneral

Samples: generalE+W

1.—(1) The local authority must ensure, so far as reasonably practicable, that the appropriate requirements are satisfied when—

(a)taking, handling, transporting and storing a sample required to be taken in accordance with this Schedule;

(b)analysing such a sample; or

(c)causing any such sample to be taken, handled, transported, stored or analysed.

(2) In this paragraph, “the appropriate requirements” means such of the following as are applicable—

(a)the sample is representative of the quality of the water at the time of sampling;

(b)the person taking a sample is subject to a system of quality control to an appropriate standard checked from time to time by a suitably accredited body;

(c)the sample is not contaminated when being taken;

(d)the sample is kept at such a temperature and in such conditions as secure that there is no material alteration of the concentration or value for the measurement or observation of which the sample is intended;

(e)the sample is analysed as soon as reasonably practicable after it has been taken—

(i)by, or under the supervision of, a person who is competent to perform that task; and

(ii)with the use of such equipment as is suitable for the purpose;

(f)the collection and transportation of samples, or measurements recorded by continuous monitoring must be subject to a system of quality control to an appropriate standard checked from time to time by a suitably accredited body.

(3) When undertaking the activity described in—

(a)sub-paragraph (1)(a), the local authority must demonstrate compliance with any of EN ISO/IEC 17024, EN ISO/EIC 17025, or another equivalent standard accepted at international level;

(b)sub-paragraph (1)(b), the local authority must demonstrate compliance with EN ISO/EIC 17025 or another equivalent standard accepted at international level.

(4) Implementation of the requirement in sub-paragraph (3)(a) may be delayed for a period of no more than 24 months beginning on the day on which these Regulations come into force.

(5) In this paragraph, “suitably accredited body” means any person accredited by the United Kingdom Accreditation Service(1).

Commencement Information

I1Sch. 4 para. 1 in force at 20.11.2017, see reg. 1

Analysing samples: microbiological parametersE+W

2.  For each parameter specified in the first column of Table 1 in Part 2 of this Schedule the method of analysis is specified in the second column of that table.

Commencement Information

I2Sch. 4 para. 2 in force at 20.11.2017, see reg. 1

Analysing samples: chemical and indicator parametersE+W

3.—(1) On or before 31 December 2019, the local authority may apply the method of analysis for chemical and indicator parameters in either sub-paragraph (3) or sub-paragraph (4).

(2) After 31 December 2019, the local authority must apply the method of analysis for chemical and indicator parameters in sub-paragraph (4).

(3) For each parameter specified in the first column of Table 2 in Part 2 of this Schedule the method is one that is capable of—

(a)measuring concentrations and values with the trueness and precision specified in the second and third columns of that table, and

(b)detecting the parameter at the limit of detection specified in the fourth column of that table.

(4) For each parameter specified in the first column of Table 3 in Part 2 of this Schedule the method is one that is capable of measuring concentrations equal to—

(a)the parametric value with a limit of quantification of 30% or less of the relevant parametric value (as contained in Schedule 1), and

(b)the uncertainty of measurement in the second column of that table.

(5) The method of analysis used for odour and taste parameters must be capable of measuring values equal to the parametric value with a precision of 1 dilution number at 25°C.

(6) For these purposes—

(a)“limit of detection” is—

(i)three times the relative within-batch standard deviation of a natural sample containing a low concentration of the parameter; or

(ii)five times the relative within-batch standard deviation of a blank sample;

(b)“precision” (the random error) is twice the standard deviation (within a batch and between batches) of the spread of results about the mean. Acceptable precision is twice the relative standard deviation. Further specifications are set out in ISO 17025;

(c)“trueness” (the systematic error) is the difference between the mean value of the large number of repeated measurements and the true value. Further specifications are set out in ISO 17025;

(d)“uncertainty of measurement” is a non-negative parameter characterising the dispersion of the quantity values being measured, based on the information used.

Commencement Information

I3Sch. 4 para. 3 in force at 20.11.2017, see reg. 1

Authorisation of alternative methods of analysisE+W

4.—(1) The Welsh Ministers may authorise a method different from those set out in paragraph 3(2) or 3(3) if satisfied that it is at least as reliable.

(2) An authorisation may be time-limited and may be revoked at any time.

Commencement Information

I4Sch. 4 para. 4 in force at 20.11.2017, see reg. 1

Sampling and analysis by persons other than local authoritiesE+W

5.—(1) A local authority may enter into an arrangement for any person to take and analyse samples on its behalf.

(2) A local authority must not enter into an arrangement under sub-paragraph (1) unless—

(a)it is satisfied that the task will be carried out promptly by a person competent to perform it, and

(b)it has made arrangements that ensure that any breach of these Regulations is communicated to it immediately, and any other result is communicated to it within 28 days.

Commencement Information

I5Sch. 4 para. 5 in force at 20.11.2017, see reg. 1

PART 2E+WAnalytical methods

Commencement Information

I6Sch. 4 Pt. 2 in force at 20.11.2017, see reg. 1

Table 1

Prescribed methods of analysis for microbiological parameters

ParameterMethod
Escherichia coli (E. coli)EN ISO 9308-1 or EN ISO 9308-2
EnterococciEN ISO 7899-2
Pseudomonas aeruginosaEN-ISO 16266
Colony count 22°C — enumeration of culturable microorganismsEN ISO 6222
Colony count 36°C — enumeration of culturable microorganismsEN ISO 6222
Clostridium perfringens (including spores)EN ISO 14189

Table 2

Prescribed performance characteristics for methods of analysis for chemical and indicator parameters: trueness, precision and limit of detection (on or before 31 December 2019)

Parameter

Trueness % of prescribed

concentration or value or specification

(except for pH)

Precision % of prescribed

concentration or value or specification

(except for pH)

Limit of detection %

of prescribed

concentration or

value or specification

(except for pH)

(1)

The method of analysis should determine total cyanide in all forms.

(2)

EN ISO 8476.

(3)

The performance characteristics apply to each individual pesticide and will depend on the pesticide concerned. Values for the uncertainty of measurement as low as 30% can be achieved for several pesticides, higher values up to 80% may be allowed for a number of pesticides.

(4)

The performance characteristics apply to the individual substances specified at 25% of the parametric value in Table B of Part 1 of Schedule 1.

(5)

The performance characteristics apply to the individual substances specified at 50% of the parametric value in Table B of Part 1of Schedule 1.

(6)

The performance characteristics apply to the prescribed value of 4 NTU.

(7)

The performance characteristics apply to the specification of 1 NTU for surface waters or ground waters influenced by surface water.

Aluminium101010
Ammonium101010
Antimony252525
Arsenic101010
Benzene252525
Benzo(a)pyrene252525
Boron101010
Bromate252525
Cadmium101010
Chloride101010
Chromium101010
Colour101010
Conductivity101010
Copper101010
Cyanide(1)101010
1.2-dichloroethane252510
Fluoride101010
Hydrogen ion concentration pH (expressed in pH units)0.20.2
Iron101010
Lead101010
Manganese101010
Mercury201020
Nickel101010
Nitrate101010
Nitrite101010
Oxidisability(2)
Pesticides and related products(3)252525
Polycyclic aromatic hydrocarbons(4)252525
Selenium101010
Sodium101010
Sulphate101010
Tetrachloroethene(5)252510
Tetrachloromethane202020
Trichloroethene(5)252510

Trihalomethanes:

Total(4)

252510
Turbidity(6)101010
Turbidity(7)252525

Table 3

Method of analysis for chemical and indicator parameters: uncertainty of measurement(1)

Parameter

Uncertainty of measurement

% of parametric value

(except for pH)

(1)

The uncertainty of measurement must not be used as an additional tolerance to the parametric values set out in Schedule 1.

(2)

If the value of uncertainty of measurement cannot be met, the best available technique should be selected (up to 60%).

(3)

The method of analysis should determine total cyanide in all forms.

(4)

EN ISO 8476.

(5)

The performance characteristics apply to each individual pesticide and will depend on the pesticide concerned. Values for the uncertainty of measurement as low as 30% can be achieved for several pesticides, higher values up to 80% may be allowed for a number of pesticides.

(6)

The performance characteristics apply to the individual substances specified at 25% of the parametric value in Table B of Part 1 of Schedule 1.

(7)

The performance characteristics apply to the individual substances specified at 50% of the parametric value in Table B of Part 1 of Schedule 1.

(8)

The uncertainty of measurement must be estimated at the level of 3mg/l of TOC. CEN 1484 Guidelines for the determination of TOC and dissolved organic carbon must be used.

(9)

The uncertainty of measurement must be estimated at the level of 1,0 NTU in accordance with EN ISO 7027.

Aluminium25
Ammonium40
Antimony40
Arsenic30
Benzene40
Benzo(a)pyrene(2)50
Boron25
Bromate40
Cadmium25
Chloride15
Chromium30
Conductivity20
Copper25
Cyanide(3)30
1,2-dichloroethane40
Fluoride20
Hydrogen ion concentration pH (expressed in pH units)0.2
Iron30
Lead25
Manganese30
Mercury30
Nickel25
Nitrate15
Nitrite20
Oxiedisability(4)50
Pesticides(5)30
Polycyclic aromatic hydrocarbons(6)50
Selenium40
Sodium15
Sulphate15
Tetrachloroethene(7)30
Trichloroethene(7)40
Trihalomethanes: total(6)40
Total organic carbon (TOC)(8)30
Turbidity(9)30

PART 3E+WMonitoring for indicative dose and analytical performance characteristics

6.  A local authority may use reliable screening strategies to indicate the presence of radioactivity in water intended for human consumption.E+W

Commencement Information

I7Sch. 4 para. 6 in force at 20.11.2017, see reg. 1

7.  The strategies referred to in paragraph 6 may include screening for—E+W

(a)certain radionuclides or individual radionuclide; or

(b)gross alpha activity or gross beta activity (where appropriate gross beta activity may be replaced by residual beta activity after subtraction of the K-40 activity concentration).

Commencement Information

I8Sch. 4 para. 7 in force at 20.11.2017, see reg. 1

Screening for certain radionuclides, or screening for an individual radionuclideE+W

8.  If one of the activity concentrations exceeds 20% of the corresponding derived value or the tritium concentration exceeds its parametric value listed in Part 3 of Schedule 1 an analysis of additional radionuclides is required.

Commencement Information

I9Sch. 4 para. 8 in force at 20.11.2017, see reg. 1

9.  A local authority must, in deciding which radionuclides require to be measured for each supply, take into account all relevant information about likely sources of radioactivity.E+W

Commencement Information

I10Sch. 4 para. 9 in force at 20.11.2017, see reg. 1

Screening strategies for gross alpha activity and gross beta activityE+W

10.  Subject to paragraph 11 the recommended screening levels are—

(a)0,1Bq/l for gross alpha activity; and

(b)1,0Bq/l for gross beta activity.

Commencement Information

I11Sch. 4 para. 10 in force at 20.11.2017, see reg. 1

11.  If the gross alpha activity exceeds 0,1Bq/l or the gross beta activity exceeds 1,0Bq/l, analysis for specific radionuclides is required.E+W

Commencement Information

I12Sch. 4 para. 11 in force at 20.11.2017, see reg. 1

12.  The Welsh Ministers may set alternative screening levels for gross alpha activity and gross beta activity where it can be demonstrated by the local authority that the alternative levels are in compliance with an indicative dose of 0,1 mSv.E+W

Commencement Information

I13Sch. 4 para. 12 in force at 20.11.2017, see reg. 1

Calculation of the indicative doseE+W

13.  The indicative dose must be calculated from—

[F1(a)the measured radionuclide concentrations and the dose coefficients referred to as “standard values and relationships” in Article 13, and recommended for the estimation of doses from internal exposure in the definition of “standard values and relationships” in Article 4(96), of Council Directive 2013/59/Euratom laying down basic safety standards for protection against the dangers arising from exposure to ionising radiation; or]

(b)more recent information recognised by the Welsh Ministers, on the basis of the annual intake of water (730 1 for adults).

Textual Amendments

Commencement Information

I14Sch. 4 para. 13 in force at 20.11.2017, see reg. 1

14.  Where the following formula is satisfied, it can be assumed that the indicative dose is less than the parametric value of 0,1 mSv and no further investigation is required—E+W

Derived concentrations for radioactivity in water intended for human consumption (1)

Origin

Nuclide

Derived concentration

(1)

This table allows only for the radiological properties of uranium, not for its chemical toxicity.

NaturalU-23833,0 Bq/l
U-23432,8 Bq/l
Ra-2260,5 Bq/l
Ra-2280,2 Bq/l
Pb-2100,2 Bq/l
Po-2100,1 Bq/l
ArtificialC-14240 Bq/l
Sr-904,9 Bq/l
Pu-239/Pu-2400,6 Bq/l
Am-2410,7 Bq/l
Co-6040 Bq/l
Cs-1347,2 Bq/l
Cs-13711 Bq/l
1-1316,2 Bq/l

Commencement Information

I15Sch. 4 para. 14 in force at 20.11.2017, see reg. 1

Performance characteristics and methods of analysisE+W

15.  For the following parameters and radionuclides, the method of analysis used must, as a minimum, be capable of measuring activity concentrations with a limit of detection specified below:

Parameters and radionuclides

Limit of detection (Notes 1,2)

Notes

Tritium10 Bq/lNote 3
Radon10 Bq/lNote 3
gross alpha0,04 Bq/lNote 4
gross beta0,4 Bq/lNote 4
U-2380,02 Bq/l
U-2340,02 Bq/l
Ra-2260,04 Bq/l
Ra-2280,02 Bq/lNote 5
Pb-2100,02 Bq/l
Po-2100,01 Bq/l
C-1420 Bq/l
Sr-900,4 Bq/l
Pu-239/Pu-2400,04 Bq/1
Am-2410,06 Bq/l
Co-600,5 Bq/1
Cs-1340,5 Bq/l
C2-1370,5 Bq/l
1-1310,5 Bq/1

Note 1: The limit of detection must be calculated according to the ISO standard 11929: Determination of the characteristic limits (decision threshold, detection limit, and limits of confidence interval) for measurements of ionising radiation — Fundamentals and application, with probabilities of errors of 1st and 2nd kind of 0,05 each.

Note 2: Measurement uncertainties must be calculated and reported as complete standard uncertainties, or as expanded uncertainties with an expansion factor of 1,96 according the ISO Guide for the Expression of Uncertainty in Measurement.

Note 3: The limit of detection for tritium and for radon is 10% of its parametric value of 100 Bq/1.

Note 4: The limit of detection for gross alpha activity and gross beta activities are 40% of the screening values of 0,1 and 1,0 Bq/1 respectively.

Note 5: This limit of detection applies only to initial screening for indicative dose for a new water source; if initial checking indicates that it is not plausible that Ra-228 exceeds 20% of the derived concentration, the limit of detection may be increased to 0,08 Bq/1 for routine Ra-228 nuclide specific measurements, until a subsequent re-check is required.

Commencement Information

I16Sch. 4 para. 15 in force at 20.11.2017, see reg. 1

(1)

See S.I. 2009/3155 for the appointment of the United Kingdom Accreditation Service as the national accreditation body.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area. The revised version is currently only available in English.

Original (As Enacted or Made) - English: The original English language version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Original (As Enacted or Made) - Welsh:The original Welsh language version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.

Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources