- Latest available (Revised)
- Original (As made)
There are currently no known outstanding effects for the The Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016, Cross Heading: POTENTIAL IGNITION SOURCES.
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
16. Potential ignition sources such as sparks, flames, electric arcs, high surface temperatures, acoustic energy, optical radiation, electromagnetic waves and other ignition sources must not occur.
Commencement Information
I1Sch. 1 para. 16 in force at 8.12.2016, see reg. 1(1)
17. Electrostatic charges capable of resulting in dangerous discharges must be prevented by means of appropriate measures.
Commencement Information
I2Sch. 1 para. 17 in force at 8.12.2016, see reg. 1(1)
18. Stray electric and leakage currents in conductive equipment parts which could result in, for example, the occurrence of dangerous corrosion, overheating of surfaces or sparks capable of provoking an ignition must be prevented.
Commencement Information
I3Sch. 1 para. 18 in force at 8.12.2016, see reg. 1(1)
19. Overheating caused by friction or impacts occurring, for example, between materials and parts in contact with each other while rotating or through the intrusion of foreign bodies must, as far as possible, be prevented at the design stage.
Commencement Information
I4Sch. 1 para. 19 in force at 8.12.2016, see reg. 1(1)
20. Equipment and protective systems must be so designed or fitted with integrated measuring, control and regulation devices that pressure compensations arising from them do not generate shock waves or compressions which may cause ignition.
Commencement Information
I5Sch. 1 para. 20 in force at 8.12.2016, see reg. 1(1)
21.—(1) Equipment and protective systems must be so designed and constructed as to be capable of performing their intended function in full safety, even in changing environmental conditions and in the presence of extraneous voltages, humidity, vibrations, contamination and other external effects, taking into account the limits of the operating conditions established by the manufacturer.
(2) Equipment parts used must be appropriate to the intended mechanical and thermal stresses and capable of withstanding attack by existing or foreseeable aggressive substances.
Commencement Information
I6Sch. 1 para. 21 in force at 8.12.2016, see reg. 1(1)
22.—(1) Safety devices must function independently of any measurement or control devices, or both measurement and control devices required for operation.
(2) As far as possible, failure of a safety device must be detected sufficiently rapidly by appropriate technical means to prevent dangerous situations from occurring.
(3) The fail-safe principle is to be applied in general.
(4) Safety-related switching must in general directly actuate the relevant control devices without intermediate software command.
(5) In the event of a safety device failure, equipment or protective systems or both must wherever possible, be secured.
(6) Emergency stop controls of safety devices must, as far as possible, be fitted with restart lockouts. A new start command may take effect on normal operation only after the restart lockouts have been intentionally reset.
Commencement Information
I7Sch. 1 para. 22 in force at 8.12.2016, see reg. 1(1)
23. Where control and display units are used, they must be designed in accordance with ergonomic principles in order to achieve the highest possible level of operating safety with regard to the risk of explosion.
Commencement Information
I8Sch. 1 para. 23 in force at 8.12.2016, see reg. 1(1)
24.—(1) In so far as they relate to equipment used in explosive atmospheres, devices with a measuring function must be designed and constructed so that they can cope with foreseeable operating requirements and special conditions of use.
(2) Where necessary, it must be possible to check the reading accuracy and serviceability of devices with a measuring function.
(3) The design of devices with a measuring function must incorporate a safety factor which ensures that the alarm threshold lies far enough outside the explosion or ignition limits of the atmospheres to be registered, or both the explosion and ignition limits, taking into account, in particular, the operating conditions of the installation and possible aberrations in the measuring system.
Commencement Information
I9Sch. 1 para. 24 in force at 8.12.2016, see reg. 1(1)
25. In the design of software-controlled equipment, protective systems and safety devices, special account must be taken of the risks arising from faults in the programme.
Commencement Information
I10Sch. 1 para. 25 in force at 8.12.2016, see reg. 1(1)
26.—(1) Manual override must be possible in order to shut down the equipment and protective systems incorporated within automatic processes which deviate from the intended operating conditions, provided that this does not compromise safety.
(2) When the emergency shutdown system is actuated, accumulated energy must be dispersed as quickly and as safely as possible or isolated so that it no longer constitutes a hazard.
(3) Sub-paragraph (2) does not apply to electrochemically-stored energy.
Commencement Information
I11Sch. 1 para. 26 in force at 8.12.2016, see reg. 1(1)
27. Where equipment and protective systems can give rise to a spread of additional risks in the event of a power failure, it must be possible to maintain them in a safe state of operation independently of the rest of the installation.
Commencement Information
I12Sch. 1 para. 27 in force at 8.12.2016, see reg. 1(1)
28.—(1) Equipment and protective systems must be fitted with suitable cable and conduit entries.
(2) When equipment and protective systems are intended for use in combination with other equipment and protective systems, the interface must be safe.
Commencement Information
I13Sch. 1 para. 28 in force at 8.12.2016, see reg. 1(1)
29. Where equipment or protective systems are fitted with detection or alarm devices for monitoring the occurrence of explosive atmospheres, the necessary instructions must be provided to enable them to be provided at the appropriate places.
Commencement Information
I14Sch. 1 para. 29 in force at 8.12.2016, see reg. 1(1)
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: