The Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres Regulations 2016

POTENTIAL IGNITION SOURCESE+W+S

Hazards arising from different ignition sourcesE+W+S

16.  Potential ignition sources such as sparks, flames, electric arcs, high surface temperatures, acoustic energy, optical radiation, electromagnetic waves and other ignition sources must not occur.

Commencement Information

I1Sch. 1 para. 16 in force at 8.12.2016, see reg. 1(1)

Hazards arising from static electricityE+W+S

17.  Electrostatic charges capable of resulting in dangerous discharges must be prevented by means of appropriate measures.

Commencement Information

I2Sch. 1 para. 17 in force at 8.12.2016, see reg. 1(1)

Hazards arising from stray electric and leakage currentsE+W+S

18.  Stray electric and leakage currents in conductive equipment parts which could result in, for example, the occurrence of dangerous corrosion, overheating of surfaces or sparks capable of provoking an ignition must be prevented.

Commencement Information

I3Sch. 1 para. 18 in force at 8.12.2016, see reg. 1(1)

Hazards arising from overheatingE+W+S

19.  Overheating caused by friction or impacts occurring, for example, between materials and parts in contact with each other while rotating or through the intrusion of foreign bodies must, as far as possible, be prevented at the design stage.

Commencement Information

I4Sch. 1 para. 19 in force at 8.12.2016, see reg. 1(1)

Hazards arising from pressure compensation operationsE+W+S

20.  Equipment and protective systems must be so designed or fitted with integrated measuring, control and regulation devices that pressure compensations arising from them do not generate shock waves or compressions which may cause ignition.

Commencement Information

I5Sch. 1 para. 20 in force at 8.12.2016, see reg. 1(1)

Hazards arising from external effectsE+W+S

21.—(1) Equipment and protective systems must be so designed and constructed as to be capable of performing their intended function in full safety, even in changing environmental conditions and in the presence of extraneous voltages, humidity, vibrations, contamination and other external effects, taking into account the limits of the operating conditions established by the manufacturer.

(2) Equipment parts used must be appropriate to the intended mechanical and thermal stresses and capable of withstanding attack by existing or foreseeable aggressive substances.

Commencement Information

I6Sch. 1 para. 21 in force at 8.12.2016, see reg. 1(1)

Requirements in respect of safety-related devicesE+W+S

22.—(1) Safety devices must function independently of any measurement or control devices, or both measurement and control devices required for operation.

(2) As far as possible, failure of a safety device must be detected sufficiently rapidly by appropriate technical means to prevent dangerous situations from occurring.

(3) The fail-safe principle is to be applied in general.

(4) Safety-related switching must in general directly actuate the relevant control devices without intermediate software command.

(5) In the event of a safety device failure, equipment or protective systems or both must wherever possible, be secured.

(6) Emergency stop controls of safety devices must, as far as possible, be fitted with restart lockouts. A new start command may take effect on normal operation only after the restart lockouts have been intentionally reset.

Commencement Information

I7Sch. 1 para. 22 in force at 8.12.2016, see reg. 1(1)

Control and display unitsE+W+S

23.  Where control and display units are used, they must be designed in accordance with ergonomic principles in order to achieve the highest possible level of operating safety with regard to the risk of explosion.

Commencement Information

I8Sch. 1 para. 23 in force at 8.12.2016, see reg. 1(1)

Requirements in respect of devices with a measuring function for explosion protectionE+W+S

24.—(1) In so far as they relate to equipment used in explosive atmospheres, devices with a measuring function must be designed and constructed so that they can cope with foreseeable operating requirements and special conditions of use.

(2) Where necessary, it must be possible to check the reading accuracy and serviceability of devices with a measuring function.

(3) The design of devices with a measuring function must incorporate a safety factor which ensures that the alarm threshold lies far enough outside the explosion or ignition limits of the atmospheres to be registered, or both the explosion and ignition limits, taking into account, in particular, the operating conditions of the installation and possible aberrations in the measuring system.

Commencement Information

I9Sch. 1 para. 24 in force at 8.12.2016, see reg. 1(1)

Risks arising from softwareE+W+S

25.  In the design of software-controlled equipment, protective systems and safety devices, special account must be taken of the risks arising from faults in the programme.

Commencement Information

I10Sch. 1 para. 25 in force at 8.12.2016, see reg. 1(1)

Integration of safety requirements relating to the systemE+W+S

26.—(1) Manual override must be possible in order to shut down the equipment and protective systems incorporated within automatic processes which deviate from the intended operating conditions, provided that this does not compromise safety.

(2) When the emergency shutdown system is actuated, accumulated energy must be dispersed as quickly and as safely as possible or isolated so that it no longer constitutes a hazard.

(3) Sub-paragraph (2) does not apply to electrochemically-stored energy.

Commencement Information

I11Sch. 1 para. 26 in force at 8.12.2016, see reg. 1(1)

Hazards arising from power failureE+W+S

27.  Where equipment and protective systems can give rise to a spread of additional risks in the event of a power failure, it must be possible to maintain them in a safe state of operation independently of the rest of the installation.

Commencement Information

I12Sch. 1 para. 27 in force at 8.12.2016, see reg. 1(1)

Hazards arising from connectionsE+W+S

28.—(1) Equipment and protective systems must be fitted with suitable cable and conduit entries.

(2) When equipment and protective systems are intended for use in combination with other equipment and protective systems, the interface must be safe.

Commencement Information

I13Sch. 1 para. 28 in force at 8.12.2016, see reg. 1(1)

Placing of warning devices as parts of equipmentE+W+S

29.  Where equipment or protective systems are fitted with detection or alarm devices for monitoring the occurrence of explosive atmospheres, the necessary instructions must be provided to enable them to be provided at the appropriate places.

Commencement Information

I14Sch. 1 para. 29 in force at 8.12.2016, see reg. 1(1)