Chwilio Deddfwriaeth

Commission Decision of 25 May 2005 establishing the classes of external fire performance of roofs and roof coverings for certain construction products as provided for by Council Directive 89/106/EEC (notified under document number C(2005) 1501) (Text with EEA relevance) (2005/403/EC)

 Help about what version

Pa Fersiwn

 Help about advanced features

Nodweddion Uwch

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

Mae hon yn eitem o ddeddfwriaeth sy’n deillio o’r UE

Mae unrhyw newidiadau sydd wedi cael eu gwneud yn barod gan y tîm yn ymddangos yn y cynnwys a chyfeirir atynt gydag anodiadau.Ar ôl y diwrnod ymadael bydd tair fersiwn o’r ddeddfwriaeth yma i’w gwirio at ddibenion gwahanol. Y fersiwn legislation.gov.uk yw’r fersiwn sy’n weithredol yn y Deyrnas Unedig. Y Fersiwn UE sydd ar EUR-lex ar hyn o bryd yw’r fersiwn sy’n weithredol yn yr UE h.y. efallai y bydd arnoch angen y fersiwn hon os byddwch yn gweithredu busnes yn yr UE. EUR-Lex Y fersiwn yn yr archif ar y we yw’r fersiwn swyddogol o’r ddeddfwriaeth fel yr oedd ar y diwrnod ymadael cyn cael ei chyhoeddi ar legislation.gov.uk ac unrhyw newidiadau ac effeithiau a weithredwyd yn y Deyrnas Unedig wedyn. Mae’r archif ar y we hefyd yn cynnwys cyfraith achos a ffurfiau mewn ieithoedd eraill o EUR-Lex. The EU Exit Web Archive legislation_originated_from_EU_p3

Changes over time for: Commission Decision of 25 May 2005 establishing the classes of external fire performance of roofs and roof coverings for certain construction products as provided for by Council Directive 89/106/EEC (notified under document number C(2005) 1501) (Text with EEA relevance) (2005/403/EC) (Annexes only)

 Help about opening options

Changes to legislation:

There are outstanding changes not yet made to Commission Decision of 25 May 2005 establishing the classes of external fire performance of roofs and roof coverings for certain construction products as provided for by Council Directive 89/106/EEC (notified under document number C(2005) 1501) (Text with EEA relevance) (2005/403/EC). Any changes that have already been made to the legislation appear in the content and are referenced with annotations. Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. Changes and effects are recorded by our editorial team in lists which can be found in the ‘Changes to Legislation’ area. Where those effects have yet to be applied to the text of the legislation by the editorial team they are also listed alongside the legislation in the affected provisions. Use the ‘more’ link to open the changes and effects relevant to the provision you are viewing.

View outstanding changes

Changes and effects yet to be applied to :

ANNEXU.K.

The table set out in this Annex lists construction products and/or materials which satisfy all the requirements for the performance characteristic external fire performance without need for testing.

Table

Classes of external fire performance for plastisol coated steel roof sheets

a

External fire performance class as provided for in the table of the Annex to Decision 2001/671/EC.

ProductClassa
Plastisol coated steel roof sheets as specified below and when incorporated into a single layer or built-up roofing system as detailed below

BROOF (t1)

BROOF (t2)

BROOF (t3)

Roofing sheets in accordance with EN 14782 and EN 14783, comprising profiled steel sheets, flat steel sheets or panels of coil coated galvanised or zinc-aluminium alloy coated steel of metal thickness ≥ 0,40 mm with an organic external (weather side) coating and, optionally, a reverse (internal) side organic coating. The external coating is of a liquid-applied Plastisol paint of maximum nominal dry film thickness 0,200 mm, a PCS of not greater than 8,0 MJ/m2 and a maximum dry mass of 330 g/m2. The reverse side organic coating (if any) has a PCS of not greater than 4,0 MJ/m2 and a maximum dry mass of 200 g/m2.

Single-layer roofing system comprising a single skin, non-insulated roofing on a supporting structure (continuous or discrete supporting rails) of reaction to fire classification A2-s1, d0 or better.

Built-up roofing system where the Plastisol coated steel roof sheets forms the external layer in a built-up assembly, where the supporting structure is of reaction to fire classification A2-s1, d0 or better and where immediately below the Plastisol coated steel sheet there is an insulating layer of reaction to fire classification A2-s1, d0 or better. This insulation shall be an un-faced mineral wool complying with EN 13162 and shall be glass fibre quilt of minimum density 10 kg/m3 (maximum nominal resin content 5 % by weight) and thickness ≥ 80 mm, or stone-wool of minimum density 25 kg/m3 (maximum nominal resin content 3,5 % by weight) and thickness ≥ 80 mm.

Joints where the top sheeting includes joints these shall be as follows:

  • trapezoidal profiled sheet — side laps to incorporate an overlap of at least one rib and end laps to be a minimum of 100 mm;

  • sinusoidal corrugated sheet — side laps to incorporate an overlap of at least 1,5 corrugations and end laps to be a minimum of 100 mm;

  • flat sheets/panels — side laps and end laps to be a minimum of 100 mm;

  • standing seam systems — side lap joints shall incorporate a vertical standing overlapped or capped seam sufficient to ensure continuous intimate contact between the sheets and to provide a watertight joint and where applicable end lap joints shall have a minimum 100 mm overlap.

Sealants shall be of a butyl-mastic or similar with a nominal density of 1 500 to 1 700 kg/m3 applied as a continuous bead within the overlapped region of the joint at a rate of approximately 45 g/m length.

Fixings where the roof sheets are fixed to the supporting construction using metal mechanical fixings adequate to provide structural stability to the roof construction with additional metal mechanical fixings used to ensure continuous intimate contact between the sheets and to provide watertight joints.

Yn ôl i’r brig

Options/Help

Print Options

Close

Mae deddfwriaeth ar gael mewn fersiynau gwahanol:

Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.

Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Close

Gweler y wybodaeth ychwanegol ochr yn ochr â’r cynnwys

Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Dewisiadau Agor

Dewisiadau gwahanol i agor deddfwriaeth er mwyn gweld rhagor o gynnwys ar y sgrin ar yr un pryd

Close

Rhagor o Adnoddau

Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:

  • y PDF print gwreiddiol y fel adopted version that was used for the EU Official Journal
  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • pob fformat o’r holl ddogfennau cysylltiedig
  • slipiau cywiro
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill
Close

Llinell Amser Newidiadau

Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.

Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.

Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.

Close

Rhagor o Adnoddau

Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:

  • y PDF print gwreiddiol y fel adopted fersiwn a ddefnyddiwyd am y copi print
  • slipiau cywiro

liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys

  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill