Chwilio Deddfwriaeth

Directive 2011/65/EU of the European Parliament and of the CouncilDangos y teitl llawn

Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment (recast) (Text with EEA relevance)

 Help about advanced features

Nodweddion Uwch

 Help about UK-EU Regulation

Legislation originating from the EU

When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.

Close

Mae hon yn eitem o ddeddfwriaeth sy’n deillio o’r UE

Mae unrhyw newidiadau sydd wedi cael eu gwneud yn barod gan y tîm yn ymddangos yn y cynnwys a chyfeirir atynt gydag anodiadau.Ar ôl y diwrnod ymadael bydd tair fersiwn o’r ddeddfwriaeth yma i’w gwirio at ddibenion gwahanol. Y fersiwn legislation.gov.uk yw’r fersiwn sy’n weithredol yn y Deyrnas Unedig. Y Fersiwn UE sydd ar EUR-lex ar hyn o bryd yw’r fersiwn sy’n weithredol yn yr UE h.y. efallai y bydd arnoch angen y fersiwn hon os byddwch yn gweithredu busnes yn yr UE. EUR-Lex Y fersiwn yn yr archif ar y we yw’r fersiwn swyddogol o’r ddeddfwriaeth fel yr oedd ar y diwrnod ymadael cyn cael ei chyhoeddi ar legislation.gov.uk ac unrhyw newidiadau ac effeithiau a weithredwyd yn y Deyrnas Unedig wedyn. Mae’r archif ar y we hefyd yn cynnwys cyfraith achos a ffurfiau mewn ieithoedd eraill o EUR-Lex. The EU Exit Web Archive legislation_originated_from_EU_p3

Status:

EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.

ANNEX IU.K. Categories of EEE covered by this Directive

1.Large household appliances.U.K.

2.Small household appliances.U.K.

3.IT and telecommunications equipment.U.K.

4.Consumer equipment.U.K.

5.Lighting equipment.U.K.

6.Electrical and electronic tools.U.K.

7.Toys, leisure and sports equipment.U.K.

8.Medical devices.U.K.

9.Monitoring and control instruments including industrial monitoring and control instruments.U.K.

10.Automatic dispensers.U.K.

11.Other EEE not covered by any of the categories above.U.K.

[F1ANNEX II U.K. Restricted substances referred to in Article 4(1) and maximum concentration values tolerated by weight in homogeneous materials

  • Lead (0,1 %)

  • Mercury (0,1 %)

  • Cadmium (0,01 %)

  • Hexavalent chromium (0,1 %)

  • Polybrominated biphenyls (PBB) (0,1 %)

  • Polybrominated diphenyl ethers (PBDE) (0,1 %)

  • Bis(2-ethylhexyl) phthalate (DEHP) (0,1 %)

  • Butyl benzyl phthalate (BBP) (0,1 %)

  • Dibutyl phthalate (DBP) (0,1 %)

  • Diisobutyl phthalate (DIBP) (0,1 %)

The restriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, from 22 July 2021 .

The restriction of DEHP, BBP, DBP and DIBP shall not apply to cables or spare parts for the repair, the reuse, the updating of functionalities or upgrading of capacity of EEE placed on the market before 22 July 2019 , and of medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, placed on the market before 22 July 2021 .

The restriction of DEHP, BBP and DBP shall not apply to toys which are already subject to the restriction of DEHP, BBP and DBP through entry 51 of Annex XVII to Regulation (EC) No 1907/2006.]

ANNEX IIIU.K.

Applications exempted from the restriction in Article 4(1)

b

[F2Directive 97/68/EC of the European Parliament and of the Council of 16 December 1997 on the approximation of the laws of the Member States relating to measures against the emission of gaseous and particulate pollutants from internal combustion engines to be installed in non-road mobile machinery ( OJ L 59, 27.2.1998, p. 1 ).]

c

[F3Council Directive 69/493/EEC of 15 December 1969 on the approximation of the laws of the Member States relating to crystal glass ( OJ L 326, 29.12.1969, p. 36 ).]

d

[F4Regulation (EU) 2016/1628 of the European Parliament and of the Council of 14 September 2016 on requirements relating to gaseous and particulate pollutant emission limits and type-approval for internal combustion engines for non-road mobile machinery, amending Regulations (EU) No 1024/2012 and (EU) No 167/2013, and amending and repealing Directive 97/68/EC ( OJ L 252, 16.9.2016, p. 53 ).]

ExemptionScope and dates of applicability
1Mercury in single capped (compact) fluorescent lamps not exceeding (per burner):
1(a)For general lighting purposes < 30 W: 5 mgExpires on 31 December 2011; 3,5 mg may be used per burner after 31 December 2011 until 31 December 2012; 2,5 mg shall be used per burner after 31 December 2012
1(b)For general lighting purposes ≥ 30 W and < 50 W: 5 mgExpires on 31 December 2011; 3,5 mg may be used per burner after 31 December 2011
1(c)For general lighting purposes ≥ 50 W and < 150 W: 5 mg
1(d)For general lighting purposes ≥ 150 W: 15 mg
1(e)For general lighting purposes with circular or square structural shape and tube diameter ≤ 17 mmNo limitation of use until 31 December 2011; 7 mg may be used per burner after 31 December 2011
1(f)For special purposes: 5 mg
[F51(g) For general lighting purposes < 30 W with a lifetime equal or above 20 000 h: 3,5 mg Expires on 31 December 2017]
2(a)Mercury in double-capped linear fluorescent lamps for general lighting purposes not exceeding (per lamp):
2(a)(1)Tri-band phosphor with normal lifetime and a tube diameter < 9 mm (e.g. T2): 5 mgExpires on 31 December 2011; 4 mg may be used per lamp after 31 December 2011
2(a)(2)Tri-band phosphor with normal lifetime and a tube diameter ≥ 9 mm and ≤ 17 mm (e.g. T5): 5 mgExpires on 31 December 2011; 3 mg may be used per lamp after 31 December 2011
2(a)(3)Tri-band phosphor with normal lifetime and a tube diameter > 17 mm and ≤ 28 mm (e.g. T8): 5 mgExpires on 31 December 2011; 3,5 mg may be used per lamp after 31 December 2011
2(a)(4)Tri-band phosphor with normal lifetime and a tube diameter > 28 mm (e.g. T12): 5 mgExpires on 31 December 2012; 3,5 mg may be used per lamp after 31 December 2012
2(a)(5)Tri-band phosphor with long lifetime (≥ 25 000 h): 8 mgExpires on 31 December 2011; 5 mg may be used per lamp after 31 December 2011
2(b)Mercury in other fluorescent lamps not exceeding (per lamp):
2(b)(1)Linear halophosphate lamps with tube > 28 mm (e.g. T10 and T12): 10 mgExpires on 13 April 2012
2(b)(2)Non-linear halophosphate lamps (all diameters): 15 mgExpires on 13 April 2016
2(b)(3)Non-linear tri-band phosphor lamps with tube diameter > 17 mm (e.g. T9)No limitation of use until 31 December 2011; 15 mg may be used per lamp after 31 December 2011
2(b)(4)Lamps for other general lighting and special purposes (e.g. induction lamps)No limitation of use until 31 December 2011; 15 mg may be used per lamp after 31 December 2011
3Mercury in cold cathode fluorescent lamps and external electrode fluorescent lamps (CCFL and EEFL) for special purposes not exceeding (per lamp):
3(a)Short length (≤ 500 mm)No limitation of use until 31 December 2011; 3,5 mg may be used per lamp after 31 December 2011
3(b)Medium length (> 500 mm and ≤ 1 500 mm)No limitation of use until 31 December 2011; 5 mg may be used per lamp after 31 December 2011
3(c)Long length (> 1 500 mm)No limitation of use until 31 December 2011; 13 mg may be used per lamp after 31 December 2011
4(a)Mercury in other low pressure discharge lamps (per lamp)No limitation of use until 31 December 2011; 15 mg may be used per lamp after 31 December 2011
4(b)Mercury in High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner) in lamps with improved colour rendering index Ra > 60:
4(b)-IP ≤ 155 WNo limitation of use until 31 December 2011; 30 mg may be used per burner after 31 December 2011
4(b)-II155 W < P ≤ 405 WNo limitation of use until 31 December 2011; 40 mg may be used per burner after 31 December 2011
4(b)-IIIP > 405 WNo limitation of use until 31 December 2011; 40 mg may be used per burner after 31 December 2011
4(c)Mercury in other High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner):
4(c)-IP ≤ 155 WNo limitation of use until 31 December 2011; 25 mg may be used per burner after 31 December 2011
4(c)-II155 W < P ≤ 405 WNo limitation of use until 31 December 2011; 30 mg may be used per burner after 31 December 2011
4(c)-IIIP > 405 WNo limitation of use until 31 December 2011; 40 mg may be used per burner after 31 December 2011
4(d)Mercury in High Pressure Mercury (vapour) lamps (HPMV)Expires on 13 April 2015
4(e)Mercury in metal halide lamps (MH)
4(f)Mercury in other discharge lamps for special purposes not specifically mentioned in this Annex
[F64(g)

Mercury in hand crafted luminous discharge tubes used for signs, decorative or architectural and specialist lighting and light-artwork, where the mercury content shall be limited as follows:

(a)

20 mg per electrode pair + 0,3 mg per tube length in cm, but not more than 80 mg, for outdoor applications and indoor applications exposed to temperatures below 20 °C;

(b)

15 mg per electrode pair + 0,24 mg per tube length in cm, but not more than 80 mg, for all other indoor applications.

Expires on 31 December 2018]
5(a)Lead in glass of cathode ray tubes
5(b)Lead in glass of fluorescent tubes not exceeding 0,2 % by weight
[F76(a) Lead as an alloying element in steel for machining purposes and in galvanised steel containing up to 0,35 % lead by weight

Expires on:

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

6(a)-I Lead as an alloying element in steel for machining purposes containing up to 0,35 % lead by weight and in batch hot dip galvanised steel components containing up to 0,2 % lead by weight Expires on 21 July 2021 for categories 1-7 and 10.]
[F86(b) Lead as an alloying element in aluminium containing up to 0,4 % lead by weight

Expires on:

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments,

  • 21 July 2023 for category 8 in vitro diagnostic medical devices,

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

6(b)-I Lead as an alloying element in aluminium containing up to 0,4 % lead by weight, provided it stems from lead-bearing aluminium scrap recycling Expires on 21 July 2021 for categories 1-7 and 10.
6(b)-II Lead as an alloying element in aluminium for machining purposes with a lead content up to 0,4 % by weight Expires on 18 May 2021 for categories 1-7 and 10.]
[F96(c) Copper alloy containing up to 4 % lead by weight

Expires on:

  • 21 July 2021 for categories 1-7 and 10,

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments,

  • 21 July 2023 for category 8 in vitro diagnostic medical devices,

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.]

[F107(a) Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead)

Applies to categories 1-7 and 10 (except applications covered by point 24 of this Annex) and expires on 21 July 2021 .

For categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments expires on 21 July 2021 .

For category 8 in vitro diagnostic medical devices expires on 21 July 2023 .

For category 9 industrial monitoring and control instruments, and for category 11 expires on 21 July 2024 .]

7(b)Lead in solders for servers, storage and storage array systems, network infrastructure equipment for switching, signalling, transmission, and network management for telecommunications
[F117(c)-I Electrical and electronic components containing lead in a glass or ceramic other than dielectric ceramic in capacitors, e.g. piezoelectronic devices, or in a glass or ceramic matrix compound

Applies to categories 1-7 and 10 (except applications covered under point 34) and expires on 21 July 2021 .

For categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments expires on 21 July 2021 .

For category 8 in vitro diagnostic medical devices expires on 21 July 2023 .

For category 9 industrial monitoring and control instruments, and for category 11 expires on 21 July 2024 .]

[F127(c)-II Lead in dielectric ceramic in capacitors for a rated voltage of 125 V AC or 250 V DC or higher

Does not apply to applications covered by point 7(c)-I and 7(c)-IV of this Annex.

Expires on:

  • 21 July 2021 for categories 1-7 and 10;

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.]

7(c)-IIILead in dielectric ceramic in capacitors for a rated voltage of less than 125 V AC or 250 V DCExpires on 1 January 2013 and after that date may be used in spare parts for EEE placed on the market before 1 January 2013
[F137(c)-IV Lead in PZT based dielectric ceramic materials for capacitors which are part of integrated circuits or discrete semiconductors

Expires on:

  • 21 July 2021 for categories 1-7 and 10;

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.]

8(a)Cadmium and its compounds in one shot pellet type thermal cut-offsExpires on 1 January 2012 and after that date may be used in spare parts for EEE placed on the market before 1 January 2012
[F148(b) Cadmium and its compounds in electrical contacts

Applies to categories 8, 9 and 11 and expires on:

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

8(b)-I

Cadmium and its compounds in electrical contacts used in:

  • circuit breakers,

  • thermal sensing controls,

  • thermal motor protectors (excluding hermetic thermal motor protectors),

  • AC switches rated at:

    • 6 A and more at 250 V AC and more, or

    • 12 A and more at 125 V AC and more,

  • DC switches rated at 20 A and more at 18 V DC and more, and

  • switches for use at voltage supply frequency ≥ 200 Hz.

Applies to categories 1 to 7 and 10 and expires on 21 July 2021 .]
9Hexavalent chromium as an anticorrosion agent of the carbon steel cooling system in absorption refrigerators up to 0,75 % by weight in the cooling solution
[F159(b) Lead in bearing shells and bushes for refrigerant-containing compressors for heating, ventilation, air conditioning and refrigeration (HVACR) applications

Applies to categories 8, 9 and 11; expires on:

  • 21 July 2023 for category 8 in vitro diagnostic medical devices,

  • 21 July 2024 for category 9 industrial monitoring and control instruments and for category 11,

  • 21 July 2021 for other subcategories of categories 8 and 9.

9(b)-(I) Lead in bearing shells and bushes for refrigerant-containing hermetic scroll compressors with a stated electrical power input equal or below 9 kW for heating, ventilation, air conditioning and refrigeration (HVACR) applications Applies to category 1; expires on 21 July 2019 .]
11(a)Lead used in C-press compliant pin connector systemsMay be used in spare parts for EEE placed on the market before 24 September 2010
11(b)Lead used in other than C-press compliant pin connector systemsExpires on 1 January 2013 and after that date may be used in spare parts for EEE placed on the market before 1 January 2013
12Lead as a coating material for the thermal conduction module C-ringMay be used in spare parts for EEE placed on the market before 24 September 2010
[F1613(a) Lead in white glasses used for optical applications

Applies to all categories; expires on:

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments and for category 11;

  • 21 July 2021 for all other categories and subcategories]

[F1713(b) Cadmium and lead in filter glasses and glasses used for reflectance standards

Applies to categories 8, 9 and 11; expires on:

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments and for category 11;

  • 21 July 2021 for other subcategories of categories 8 and 9

13(b)-(I) Lead in ion coloured optical filter glass types Applies to categories 1 to 7 and 10; expires on 21 July 2021 for categories 1 to 7 and 10
13(b)-(II) Cadmium in striking optical filter glass types; excluding applications falling under point 39 of this Annex
13(b)-(III) Cadmium and lead in glazes used for reflectance standards]
14Lead in solders consisting of more than two elements for the connection between the pins and the package of microprocessors with a lead content of more than 80 % and less than 85 % by weightExpired on 1 January 2011 and after that date may be used in spare parts for EEE placed on the market before 1 January 2011
[F1815 Lead in solders to complete a viable electrical connection between semiconductor die and carrier within integrated circuit flip chip packages

Applies to categories 8, 9 and 11 and expires on:

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

15(a)

Lead in solders to complete a viable electrical connection between the semiconductor die and carrier within integrated circuit flip chip packages where at least one of the following criteria applies:

  • a semiconductor technology node of 90 nm or larger;

  • a single die of 300 mm 2 or larger in any semiconductor technology node;

  • stacked die packages with die of 300 mm 2 or larger, or silicon interposers of 300 mm 2 or larger.

Applies to categories 1 to 7 and 10 and expires on 21 July 2021 .]
16Lead in linear incandescent lamps with silicate coated tubesExpires on 1 September 2013
17Lead halide as radiant agent in high intensity discharge (HID) lamps used for professional reprography applications
18(a)Lead as activator in the fluorescent powder (1 % lead by weight or less) of discharge lamps when used as speciality lamps for diazoprinting reprography, lithography, insect traps, photochemical and curing processes containing phosphors such as SMS ((Sr,Ba)2MgSi2O7:Pb)Expired on 1 January 2011
[F1918(b) Lead as activator in the fluorescent powder (1 % lead by weight or less) of discharge lamps when used as sun tanning lamps containing phosphors such as BSP (BaSi2O5:Pb)

Expires on:

  • 21 July 2021 for categories 1-7 and 10;

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

18(b)-I Lead as activator in the fluorescent powder (1 % lead by weight or less) of discharge lamps containing phosphors such as BSP (BaSi2O5:Pb) when used in medical phototherapy equipment Applies to categories 5 and 8, excluding applications covered by entry 34 of Annex IV, and expires on 21 July 2021 .]
19Lead with PbBiSn-Hg and PbInSn-Hg in specific compositions as main amalgam and with PbSn-Hg as auxiliary amalgam in very compact energy saving lamps (ESL)Expires on 1 June 2011
20Lead oxide in glass used for bonding front and rear substrates of flat fluorescent lamps used for Liquid Crystal Displays (LCDs)Expires on 1 June 2011
[F2021 Lead and cadmium in printing inks for the application of enamels on glasses, such as borosilicate and soda lime glasses

Applies to categories 8, 9 and 11 and expires on:

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

21(a) Cadmium when used in colour printed glass to provide filtering functions, used as a component in lighting applications installed in displays and control panels of EEE Applies to categories 1 to 7 and 10 except applications covered by entry 21(b) or entry 39 and expires on 21 July 2021 .
21(b) Cadmium in printing inks for the application of enamels on glasses, such as borosilicate and soda lime glasses Applies to categories 1 to 7 and 10 except applications covered by entry 21(a) or 39 and expires on 21 July 2021 .
21(c) Lead in printing inks for the application of enamels on other than borosilicate glasses Applies to categories 1 to 7 and 10 and expires on 21 July 2021 .]
23Lead in finishes of fine pitch components other than connectors with a pitch of 0,65 mm and lessMay be used in spare parts for EEE placed on the market before 24 September 2010
[F2124 Lead in solders for the soldering to machined through hole discoidal and planar array ceramic multilayer capacitors

Expires on:

  • 21 July 2021 for categories 1-7 and 10,

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments,

  • 21 July 2023 for category 8 in vitro diagnostic medical devices,

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.]

25Lead oxide in surface conduction electron emitter displays (SED) used in structural elements, notably in the seal frit and frit ring
26Lead oxide in the glass envelope of black light blue lampsExpires on 1 June 2011
27Lead alloys as solder for transducers used in high-powered (designated to operate for several hours at acoustic power levels of 125 dB SPL and above) loudspeakersExpired on 24 September 2010
[F329 Lead bound in crystal glass as defined in Annex I (Categories 1, 2, 3 and 4) of Council Directive 69/493/EEC c

Expires on:

  • 21 July 2021 for categories 1-7 and 10;

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and ontrol instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.]

30Cadmium alloys as electrical/mechanical solder joints to electrical conductors located directly on the voice coil in transducers used in high-powered loudspeakers with sound pressure levels of 100 dB (A) and more
31Lead in soldering materials in mercury free flat fluorescent lamps (which, e.g. are used for liquid crystal displays, design or industrial lighting)
[F2232 Lead oxide in seal frit used for making window assemblies for Argon and Krypton laser tubes

Expires on:

  • 21 July 2021 for categories 1-7 and 10,

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments,

  • 21 July 2023 for category 8 in vitro diagnostic medical devices,

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.]

33Lead in solders for the soldering of thin copper wires of 100 μm diameter and less in power transformers
[F2334 Lead in cermet-based trimmer potentiometer elements

Applies to all categories; expires on:

  • 21 July 2021 for categories 1-7 and 10,

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments,

  • 21 July 2023 for category 8 in vitro diagnostic medical devices,

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.]

36Mercury used as a cathode sputtering inhibitor in DC plasma displays with a content up to 30 mg per displayExpired on 1 July 2010
[F2437 Lead in the plating layer of high voltage diodes on the basis of a zinc borate glass body

Expires on:

  • 21 July 2021 for categories 1-7 and 10;

  • 21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

  • 21 July 2023 for category 8 in vitro diagnostic medical devices;

  • 21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.]

38Cadmium and cadmium oxide in thick film pastes used on aluminium bonded beryllium oxide
[F2539(a) Cadmium selenide in downshifting cadmium-based semiconductor nanocrystal quantum dots for use in display lighting applications (< 0,2 μg Cd per mm 2 of display screen area) [X1Expires for all categories on 31 October 2019] ]
[F2640 Cadmium in photoresistors for analogue optocouplers applied in professional audio equipment Expires on 31 December 2013]
[F241 Lead in solders and termination finishes of electrical and electronic components and finishes of printed circuit boards used in ignition modules and other electrical and electronic engine control systems, which for technical reasons must be mounted directly on or in the crankcase or cylinder of hand-held combustion engines (classes SH:1, SH:2, SH:3 of Directive 97/68/EC of the European Parliament and of the Council b ) Expires on 31 December 2018]
[F2742

Lead in bearings and bushes of diesel or gaseous fuel powered internal combustion engines applied in non-road professional use equipment:

  • with engine total displacement ≥ 15 litres;

    or

  • with engine total displacement < 15 litres and the engine is designed to operate in applications where the time between signal to start and full load is required to be less than 10 seconds; or regular maintenance is typically performed in a harsh and dirty outdoor environment, such as mining, construction, and agriculture applications.

Applies to category 11, excluding applications covered by entry 6(c) of this Annex.

Expires on 21 July 2024 .]

[F2843

Bis(2-ethylhexyl) phthalate in rubber components in engine systems, designed for use in equipment that is not intended solely for consumer use and provided that no plasticised material comes into contact with human mucous membranes or into prolonged contact with human skin and the concentration value of bis(2-ethylhexyl) phthalate does not exceed:

(a)

30 % by weight of the rubber for

(i)

gasket coatings;

(ii)

solid-rubber gaskets; or

(iii)

rubber components included in assemblies of at least three components using electrical, mechanical or hydraulic energy to do work, and attached to the engine.

(b)

10 % by weight of the rubber for rubber-containing components not referred to in point (a).

For the purposes of this entry, prolonged contact with human skin means continuous contact of more than 10 minutes duration or intermittent contact over a period of 30 minutes, per day.

Applies to category 11 and expires on 21 July 2024 .]
[F444 Lead in solder of sensors, actuators, and engine control units of combustion engines within the scope of Regulation (EU) 2016/1628 of the European Parliament and of the Council d , installed in equipment used at fixed positions while in operation which is designed for professionals, but also used by non-professional users Applies to category 11 and expires on 21 July 2024 .]

Editorial Information

Textual Amendments

ANNEX IVU.K. Applications exempted from the restriction in Article 4(1) specific to medical devices and monitoring and control instruments

Equipment utilising or detecting ionising radiationU.K.

1.Lead, cadmium and mercury in detectors for ionising radiation.U.K.

2.Lead bearings in X-ray tubes.U.K.

3.Lead in electromagnetic radiation amplification devices: micro-channel plate and capillary plate.U.K.

4.Lead in glass frit of X-ray tubes and image intensifiers and lead in glass frit binder for assembly of gas lasers and for vacuum tubes that convert electromagnetic radiation into electrons.U.K.

5.Lead in shielding for ionising radiation.U.K.

6.Lead in X-ray test objects.U.K.

7.Lead stearate X-ray diffraction crystals.U.K.

8.Radioactive cadmium isotope source for portable X-ray fluorescence spectrometers.U.K.

Sensors, detectors and electrodesU.K.

1a.Lead and cadmium in ion selective electrodes including glass of pH electrodes.U.K.
1b.Lead anodes in electrochemical oxygen sensors.U.K.
1c.Lead, cadmium and mercury in infra-red light detectors.U.K.
1d.Mercury in reference electrodes: low chloride mercury chloride, mercury sulphate and mercury oxide.U.K.

OthersU.K.

9.Cadmium in helium-cadmium lasers.U.K.

10.Lead and cadmium in atomic absorption spectroscopy lamps.U.K.

11.Lead in alloys as a superconductor and thermal conductor in MRI.U.K.

[F2912. Lead and cadmium in metallic bonds creating superconducting magnetic circuits in MRI, SQUID, NMR (Nuclear Magnetic Resonance) or FTMS (Fourier Transform Mass Spectrometer) detectors. Expires on 30 June 2021 .] U.K.

13.Lead in counterweights.U.K.

14.Lead in single crystal piezoelectric materials for ultrasonic transducers.U.K.

15.Lead in solders for bonding to ultrasonic transducers.U.K.

16.Mercury in very high accuracy capacitance and loss measurement bridges and in high frequency RF switches and relays in monitoring and control instruments not exceeding 20 mg of mercury per switch or relay.U.K.

17.Lead in solders in portable emergency defibrillators.U.K.

18.Lead in solders of high performance infrared imaging modules to detect in the range 8-14 μm.U.K.

19.Lead in Liquid crystal on silicon (LCoS) displays.U.K.

20.Cadmium in X-ray measurement filters.U.K.

[F3021. Cadmium in phosphor coatings in image intensifiers for X-ray images until 31 December 2019 and in spare parts for X-ray systems placed on the EU market before 1 January 2020 .] U.K.

[F3122. Lead acetate marker for use in stereotactic head frames for use with CT and MRI and in positioning systems for gamma beam and particle therapy equipment. Expires on 30 June 2021 .] U.K.

[F3223. Lead as an alloying element for bearings and wear surfaces in medical equipment exposed to ionising radiation. Expires on 30 June 2021 .] U.K.

[F3324. Lead enabling vacuum tight connections between aluminium and steel in X-ray image intensifiers. Expires on 31 December 2019 .] U.K.

[F3425. Lead in the surface coatings of pin connector systems requiring nonmagnetic connectors which are used durably at a temperature below – 20 °C under normal operating and storage conditions. Expires on 30 June 2021 .] U.K.

[F3526. Lead in the following applications that are used durably at a temperature below – 20 °C under normal operating and storage conditions: U.K.

(a)

solders on printed circuit boards;

(b)

termination coatings of electrical and electronic components and coatings of printed circuit boards;

(c)

solders for connecting wires and cables;

(d)

solders connecting transducers and sensors.

Lead in solders of electrical connections to temperature measurement sensors in devices which are designed to be used periodically at temperatures below – 150 °C.

These exemptions expire on 30 June 2021 .]

[F3627. Lead in U.K.

  • solders,

  • termination coatings of electrical and electronic components and printed circuit boards,

  • connections of electrical wires, shields and enclosed connectors,

which are used in

(a)

magnetic fields within the sphere of 1 m radius around the isocentre of the magnet in medical magnetic resonance imaging equipment, including patient monitors designed to be used within this sphere, or

(b)

magnetic fields within 1 m distance from the external surfaces of cyclotron magnets, magnets for beam transport and beam direction control applied for particle therapy.

Expires on 30 June 2020 .]

[F3728. Lead in solders for mounting cadmium telluride and cadmium zinc telluride digital array detectors to printed circuit boards. Expires on 31 December 2017 .] U.K.

[F3829. Lead in alloys, as a superconductor or thermal conductor, used in cryo-cooler cold heads and/or in cryo-cooled cold probes and/or in cryo-cooled equipotential bonding systems, in medical devices (category 8) and/or in industrial monitoring and control instruments. Expires on 30 June 2021 .] U.K.

[F3930. Hexavalent chromium in alkali dispensers used to create photocathodes in X-ray image intensifiers until 31 December 2019 and in spare parts for X-ray systems placed on the EU market before 1 January 2020 .] U.K.

F4031.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .U.K.

[F4131a. Lead, cadmium, hexavalent chromium, and polybrominated diphenyl ethers (PBDE) in spare parts recovered from and used for the repair or refurbishment of medical devices, including in vitro diagnostic medical devices, or electron microscopes and their accessories, provided that the reuse takes place in auditable closed-loop business-to-business return systems and that each reuse of parts is notified to the customer. U.K.

Expires on:

(a)

21 July 2021 for the use in medical devices other than in vitro diagnostic medical devices;

(b)

21 July 2023 for the use in in vitro diagnostic medical devices;

(c)

21 July 2024 for the use in electron microscopes and their accessories.]

[F4232. Lead in solders on printed circuit boards of detectors and data acquisition units for Positron Emission Tomographs which are integrated into Magnetic Resonance Imaging equipment. Expires on 31 December 2019 .] U.K.

[F4333. Lead in solders on populated printed circuit boards used in Directive 93/42/EEC class IIa and IIb mobile medical devices other than portable emergency defibrillators. Expires on 30 June 2016 for class IIa and on 31 December 2020 for class IIb.] U.K.

[F4434. Lead as an activator in the fluorescent powder of discharge lamps when used for extracorporeal photopheresis lamps containing BSP (BaSi 2 O 5 :Pb) phosphors. Expires on 22 July 2021 .] U.K.

[F4535. Mercury in cold cathode fluorescent lamps for back-lighting liquid crystal displays, not exceeding 5 mg per lamp, used in industrial monitoring and control instruments placed on the market before 22 July 2017 U.K.

Expires on 21 July 2024 .]

[F4636. Lead used in other than C-press compliant pin connector systems for industrial monitoring and control instruments. U.K.

Expires on 31 December 2020 . May be used after that date in spare parts for industrial monitoring and control instruments placed on the market before 1 January 2021 .]

[F4737. Lead in platinized platinum electrodes used for conductivity measurements where at least one of the following conditions applies: U.K.

(a)

wide-range measurements with a conductivity range covering more than 1 order of magnitude (e.g. range between 0,1 mS/m and 5 mS/m) in laboratory applications for unknown concentrations;

(b)

measurements of solutions where an accuracy of +/– 1 % of the sample range and where high corrosion resistance of the electrode are required for any of the following:

(i)

solutions with an acidity < pH 1;

(ii)

solutions with an alkalinity > pH 13;

(iii)

corrosive solutions containing halogen gas;

(c)

measurements of conductivities above 100 mS/m that must be performed with portable instruments.

Expires on 31 December 2018 .]

[F4838. Lead in solder in one interface of large area stacked die elements with more than 500 interconnects per interface which are used in X-ray detectors of computed tomography and X-ray systems. U.K.

Expires on 31 December 2019 . May be used after that date in spare parts for CT and X-ray systems placed on the market before 1 January 2020 .]

[F4939. Lead in micro-channel plates (MCPs) used in equipment where at least one of the following properties is present: U.K.

(a)

a compact size of the detector for electrons or ions, where the space for the detector is limited to a maximum of 3 mm/MCP (detector thickness + space for installation of the MCP), a maximum of 6 mm in total, and an alternative design yielding more space for the detector is scientifically and technically impracticable;

(b)

a two-dimensional spatial resolution for detecting electrons or ions, where at least one of the following applies:

(i)

a response time shorter than 25 ns;

(ii)

a sample detection area larger than 149 mm 2 ;

(iii)

a multiplication factor larger than 1,3 × 10 3 .

(c)

a response time shorter than 5 ns for detecting electrons or ions;

(d)

a sample detection area larger than 314 mm 2 for detecting electrons or ions;

(e)

a multiplication factor larger than 4,0 × 10 7 .

The exemption expires on the following dates:

(a)

21 July 2021 for medical devices and monitoring and control instruments;

(b)

21 July 2023 for in-vitro diagnostic medical devices;

(c)

21 July 2024 for industrial monitoring and control instruments.]

[F5040. Lead in dielectric ceramic in capacitors for a rated voltage of less than 125 V AC or 250 V DC for industrial monitoring and control instruments. U.K.

Expires on 31 December 2020 . May be used after that date in spare parts for industrial monitoring and control instruments placed on the market before 1 January 2021 .]

[F5141. Lead as a thermal stabiliser in polyvinyl chloride (PVC) used as base material in amperometric, potentiometric and conductometric electrochemical sensors which are used in in-vitro diagnostic medical devices for the analysis of blood and other body fluids and body gases. U.K.

Expires on 31 December 2018 .]

[F5242. Mercury in electric rotating connectors used in intravascular ultrasound imaging systems capable of high operating frequency (> 50 MHz) modes of operation. U.K.

Expires on 30 June 2019 .]

[F5343. Cadmium anodes in Hersch cells for oxygen sensors used in industrial monitoring and control instruments, where sensitivity below 10 ppm is required. U.K.

Expires on 15 July 2023 .]

[F5444. Cadmium in radiation tolerant video camera tubes designed for cameras with a centre resolution greater than 450 TV lines which are used in environments with ionising radiation exposure exceeding 100 Gy/hour and a total dose in excess of 100kGy. U.K.

Applies to category 9. Expires on 31 March 2027 .]

ANNEX VU.K. Applications for granting, renewing and revoking exemptions as referred to in Article 5

Applications for exemptions, renewal of exemptions or, mutatis mutandis, for revoking an exemption may be submitted by a manufacturer, the authorised representative of a manufacturer, or any economic operator in the supply chain and shall include at least the following:

(a)

the name, address and contact details of the applicant;

(b)

information on the material or component and the specific uses of the substance in the material and component for which an exemption, or its revocation, is requested and its particular characteristics;

(c)

verifiable and referenced justification for an exemption, or its revocation, in line with the conditions established in Article 5;

(d)

an analysis of possible alternative substances, materials or designs on a life-cycle basis, including, when available, information about independent research, peer-review studies and development activities by the applicant and an analysis of the availability of such alternatives;

(e)

information on the possible preparation for reuse or recycling of materials from waste EEE, and on the provisions relating to the appropriate treatment of waste according to Annex II to Directive 2002/96/EC;

(f)

other relevant information;

(g)

the proposed actions to develop, request the development and/or to apply possible alternatives including a timetable for such actions by the applicant;

(h)

where appropriate, an indication of the information which should be regarded as proprietary accompanied by verifiable justification;

(i)

when applying for an exemption, proposal for a precise and clear wording for the exemption;

(j)

a summary of the application.

ANNEX VIU.K. EU DECLARATION OF CONFORMITY

1.No … (unique identification of the EEE):U.K.

2.Name and address of the manufacturer or his authorised representative:U.K.

3.This declaration of conformity is issued under the sole responsibility of the manufacturer (or installer):U.K.

4.Object of the declaration (identification of EEE allowing traceability. It may include a photograph, where appropriate):U.K.

5.The object of the declaration described above is in conformity with Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment(1):U.K.

6.Where applicable, references to the relevant harmonised standards used or references to the technical specifications in relation to which conformity is declared:U.K.

7.Additional information:U.K.

Signed for and on behalf of: …

(place and date of issue):

(name, function) (signature):

ANNEX VIIU.K.

PART AU.K.

Repealed Directive with its successive amendments

(referred to in Article 26)

Directive 2002/95/EC of the European Parliament and of the Council(OJ L 37, 13.2.2003, p. 19).
Commission Decision 2005/618/EC(OJ L 214, 19.8.2005, p. 65).
Commission Decision 2005/717/EC(OJ L 271, 15.10.2005, p. 48).
Commission Decision 2005/747/EC(OJ L 280, 25.10.2005, p. 18).
Commission Decision 2006/310/EC(OJ L 115, 28.4.2006, p. 38).
Commission Decision 2006/690/EC(OJ L 283, 14.10.2006, p. 47).
Commission Decision 2006/691/EC(OJ L 283, 14.10.2006, p. 48).
Commission Decision 2006/692/EC(OJ L 283, 14.10.2006, p. 50).
Directive 2008/35/EC of the European Parliament and of the Council(OJ L 81, 20.3.2008, p. 67).
Commission Decision 2008/385/EC(OJ L 136, 24.5.2008, p. 9).
Commission Decision 2009/428/EC(OJ L 139, 5.6.2009, p. 32).
Commission Decision 2009/443/EC(OJ L 148, 11.6.2009, p. 27).
Commission Decision 2010/122/EU(OJ L 49, 26.2.2010, p. 32).
Commission Decision 2010/571/EU(OJ L 251, 25.9.2010, p. 28).

PART BU.K.

List of time-limits for transposition into national law

(referred to in Article 26)

DirectiveDeadline for transposition
2002/95/EC12 August 2004
2008/35/EC

ANNEX VIIIU.K.

Correlation table

Directive 2002/95/ECThis Directive
Article 1Article 1
Article 2(1)Article 2(1), 2(2), Annex I
Article 2(2)Article 2(3)
Article 2(3)Article 2(4), introductory wording
Article 2(4)
Article 3(a)Article 3(1),(2)
Article 3(b)
Article 3(6)-(28)
Article 4(1)Article 4(1), Annex II
Article 4(3)-(4)
Article 4(2)Article 4(6)
Article 4(3)
Article 5(1), introductory wordingArticle 5(1), introductory wording
Article 5(1)(a)Article 4(2)
Article 5(1)(b)Article 5(1)(a), first and third indents

Article 5(1)(a), second indent

Article 5(1)(a), final paragraph

Article 5(1)(c)Article 5(1)(b)

Article 5(2)

Article 5(3)-(6)

Article 5(2)Article 5(7)
Article 5(8)
Article 6Article 6
Article 7-18
Article 7Articles 19-22
Article 8Article 23
Article 9Article 25
Article 26
Article 10Article 27
Article 11Article 28
Annexes I-II
Annex, points 1-39Annex III, points 1-39
Annexes IV, V, VI-VIII

Yn ôl i’r brig

Options/Help

Print Options

Close

Mae deddfwriaeth ar gael mewn fersiynau gwahanol:

Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.

Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.

Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

Gweler y wybodaeth ychwanegol ochr yn ochr â’r cynnwys

Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Dewisiadau Agor

Dewisiadau gwahanol i agor deddfwriaeth er mwyn gweld rhagor o gynnwys ar y sgrin ar yr un pryd

Close

Rhagor o Adnoddau

Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:

  • y PDF print gwreiddiol y fel adopted version that was used for the EU Official Journal
  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • pob fformat o’r holl ddogfennau cysylltiedig
  • slipiau cywiro
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill
Close

Llinell Amser Newidiadau

Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.

Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.

Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.

Close

Rhagor o Adnoddau

Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:

  • y PDF print gwreiddiol y fel adopted fersiwn a ddefnyddiwyd am y copi print
  • slipiau cywiro

liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys

  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill