- Y Diweddaraf sydd Ar Gael (Diwygiedig)
- Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE)
Commission Regulation (EU) 2015/1189 of 28 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for solid fuel boilers (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Mae unrhyw newidiadau sydd wedi cael eu gwneud yn barod gan y tîm yn ymddangos yn y cynnwys a chyfeirir atynt gydag anodiadau.Ar ôl y diwrnod ymadael bydd tair fersiwn o’r ddeddfwriaeth yma i’w gwirio at ddibenion gwahanol. Y fersiwn legislation.gov.uk yw’r fersiwn sy’n weithredol yn y Deyrnas Unedig. Y Fersiwn UE sydd ar EUR-lex ar hyn o bryd yw’r fersiwn sy’n weithredol yn yr UE h.y. efallai y bydd arnoch angen y fersiwn hon os byddwch yn gweithredu busnes yn yr UE. EUR-Lex Y fersiwn yn yr archif ar y we yw’r fersiwn swyddogol o’r ddeddfwriaeth fel yr oedd ar y diwrnod ymadael cyn cael ei chyhoeddi ar legislation.gov.uk ac unrhyw newidiadau ac effeithiau a weithredwyd yn y Deyrnas Unedig wedyn. Mae’r archif ar y we hefyd yn cynnwys cyfraith achos a ffurfiau mewn ieithoedd eraill o EUR-Lex. The EU Exit Web Archive legislation_originated_from_EU_p3
There are currently no known outstanding effects for the Commission Regulation (EU) 2015/1189.
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
For the purposes of Annexes II to V the following definitions shall apply:
‘seasonal space heating emissions’ means:
for automatically stoked solid fuel boilers, a weighted average of the emissions at rated heat output and the emissions at 30 % of the rated heat output, expressed in mg/m3;
for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, a weighted average of the emissions at rated heat output and the emissions at 50 % of the rated heat output, expressed in mg/m3;
for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, the emissions at rated heat output, expressed in mg/m3;
for solid fuel cogeneration boilers, the emissions at rated heat output, expressed in mg/m3.
‘fossil fuel boiler’ means a solid fuel boiler that has fossil fuel or a blend of biomass and fossil fuel as preferred fuel;
‘solid fuel boiler housing’ means the part of a solid fuel boiler designed for fitting a solid fuel heat generator;
‘model identifier’ means the code, usually alphanumeric, which distinguishes a specific solid fuel boiler model from other models with the same trade mark or manufacturer's name;
‘condensing boiler’ means a solid fuel boiler in which, under normal operating conditions and at given operating water temperatures, the water vapour in the combustion products is partially condensed, in order to make use of the latent heat of this water vapour for heating purposes;
‘combination boiler’ means a solid fuel boiler that is designed to also provide heat to deliver hot drinking or sanitary water at given temperature levels, quantities and flow rates during given intervals, and is connected to an external supply of drinking or sanitary water;
‘other woody biomass’ means woody biomass other than: log wood with a moisture content of 25 % or less, chipped wood with a moisture content of 15 % or higher, compressed wood in the form of pellets or briquettes, or sawdust with a moisture content equal to or less than 50 %;
‘moisture content’ means the mass of water in the fuel in relation to the total mass of the fuel as used in solid fuel boilers;
‘other fossil fuel’ means fossil fuel other than bituminous coal, brown coal (including briquettes), coke, anthracite or blended fossil fuel briquettes;
‘electrical efficiency’ or ‘ηel ’ means the ratio of the electricity output and the total energy input of a solid fuel cogeneration boiler, expressed in %, whereby the total energy input is expressed in terms of GCV or in terms of final energy multiplied by CC;
‘gross calorific value’ or ‘GCV’ means the total amount of heat released by a unit quantity of fuel containing the appropriate moisture content, when it is burned completely with oxygen, and when the products of combustion are returned to ambient temperature; this quantity includes the condensation heat of the water vapour formed by the combustion of any hydrogen contained in the fuel;
[F1‘conversion coefficient’ (CC) means a coefficient the value of which is CC = 2.5.]
‘electric power requirement at maximum heat output’ or ‘elmax ’ means the electric power consumption of the solid fuel boiler at rated heat output, expressed in kW, excluding electricity consumption from a back-up heater and from incorporated secondary emission abatement equipment;
‘electric power requirement at minimum heat output’ or ‘elmin ’ means the electric power consumption of the solid fuel boiler at applicable part load, expressed in kW, excluding electricity consumption from a back-up heater and from incorporated secondary emission abatement equipment;
‘back-up heater’ means a Joule-effect electric resistance element that generates heat only to prevent the solid fuel boiler or the water-based central heating system from freezing or when the external heat source supply is disrupted (including during maintenance periods) or out of order;
‘applicable part load’ means for automatically stoked solid fuel boilers, operation at 30 % of rated heat output, and for manually stoked solid fuel boilers that can be operated at 50 % of rated heat output, operation at 50 % of rated heat output;
‘standby mode power consumption’ or ‘PSB ’ means the power consumption of a solid fuel boiler in standby mode, excluding from incorporated secondary emission abatement equipment, expressed in kW;
‘standby mode’ means a condition where the solid fuel boiler is connected to the mains power source, depends on energy input from the mains power source to work as intended and provides only the following functions, which may persist for an indefinite time: reactivation function, or reactivation function and only an indication of enabled reactivation function, or information or status display;
‘seasonal space heating energy efficiency in active mode’ or ‘ηson ’ means:
for automatically stoked solid fuel boilers, a weighted average of the useful efficiency at rated heat output and the useful efficiency at 30 % of the rated heat output, expressed in %;
for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, a weighted average of the useful efficiency at rated heat output and the useful efficiency at 50 % of the rated heat output, expressed in %;
for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, the useful efficiency at rated heat output, expressed in %;
for solid fuel cogeneration boilers, the useful efficiency at rated heat output, expressed in %;
‘useful efficiency’ or ‘η’ means the ratio of the useful heat output and the total energy input of a solid fuel boiler, expressed in %, whereby the total energy input is expressed in terms of GCV or in terms of final energy multiplied by CC;
‘useful heat output’ or ‘P’ means the heat output of a solid fuel boiler transmitted to the heat carrier, expressed in kW;
‘temperature control’ means the equipment that interfaces with the end-user regarding the values and timing of the desired indoor temperature, and communicates relevant data to an interface of the solid fuel boiler such as a central processing unit, thus helping to regulate the indoor temperature(s);
‘gross calorific value moisture free’ or ‘GCVmf ’ means the total amount of heat released by a unit quantity of fuel dried of inherent moisture, when it is burned completely with oxygen, and when the products of combustion are returned to ambient temperature; this quantity includes the condensation heat of the water vapour formed by the combustion of any hydrogen contained in the fuel;
‘equivalent model’ means a model placed on the market with the same technical parameters set out in Table 1 of point 2 of Annex II as another model placed on the market by the same manufacturer.
Textual Amendments
From 1 January 2020 solid fuel boilers shall comply with the following requirements:
seasonal space heating energy efficiency for boilers with a rated heat output of 20 kW or less shall not be less than 75 %;
seasonal space heating energy efficiency for boilers with a rated heat output of more than 20 kW shall not be less than 77 %;
seasonal space heating emissions of particulate matter shall not be higher than 40 mg/m3 for automatically stoked boilers and not be higher than 60 mg/m3 for manually stoked boilers;
seasonal space heating emissions of organic gaseous compounds shall not be higher than 20 mg/m3 for automatically stoked boilers and not be higher than 30 mg/m3 for manually stoked boilers;
seasonal space heating emissions of carbon monoxide shall not be higher than 500 mg/m3 for automatically stoked boilers and not be higher than 700 mg/m3 for manually stoked boilers;
seasonal space heating emissions of nitrogen oxides, expressed in nitrogen dioxide, shall not be higher than 200 mg/m3 for biomass boilers and not be higher than 350 mg/m3 for fossil fuel boilers;
These requirements shall be met for the preferred fuel and for any other suitable fuel for the solid fuel boiler.
From 1 January 2020 the following product information on solid fuel boilers shall be provided:
in the instruction manuals for installers and end-users, and on the free-access websites of manufacturers, their authorised representatives and importers:
the information included in Table 1, with its technical parameters measured and calculated in accordance with Annex III and showing the number of significant figures indicated in the table;
any specific precautions to be taken when the solid fuel boiler is assembled, installed or maintained;
instruction on the proper way to operate the solid fuel boiler and on the quality requirements for the preferred fuel and any other suitable fuels;
for solid fuel heat generators designed for solid fuel boilers, and solid fuel boiler housings to be equipped with such heat generators, their characteristics, the requirements for assembly (to ensure compliance with the ecodesign requirements for solid fuel boilers) and, where appropriate, the list of combinations recommended by the manufacturer;
on a part for professionals of the free-access websites of manufacturers, their authorised representatives and importers: information relevant to disassembly, recycling and disposal at end-of-life;
in the technical documentation for the purposes of conformity assessment pursuant to Article 4:
the information listed in points (a) and (b);
a list of all equivalent models, if applicable;
where the preferred fuel or any other suitable fuel is other woody biomass, non-woody biomass, other fossil fuel or other blend of biomass and fossil fuel as referred to in Table 1, a description of the fuel sufficient for its unambiguous identification and the technical standard or specification of the fuel, including the measured moisture content, and the measured ash content, and for other fossil fuel also the measured volatile content of the fuel;
the electrical capacity, marked in a permanent manner on the solid fuel cogeneration boiler.
The information referred to in point (c) may be merged with the technical documentation provided in accordance with measures under Directive 2010/30/EU.
Information requirements for solid fuel boilers
a Tank volume = 45 × Pr × (1 – 2,7/Pr ) or 300 litres, whichever is higher, with Pr indicated in kW | |||||||||||||
b Tank volume = 20 × Pr with Pr indicated in kW | |||||||||||||
c For the preferred fuel Pn equals Pr | |||||||||||||
d PM = particulate matter, OGC = organic gaseous compounds, CO = carbon monoxide, NOx = nitrogen oxides | |||||||||||||
Model identifier(s) | |||||||||||||
Stoking mode: [Manual: the boiler should be operated with a hot water storage tank of a volume of at least xa litre/Automatic: it is recommended that the boiler be operated with a hot water storage tank of a volume of at least xb litre] | |||||||||||||
Condensing boiler: [yes/no] | |||||||||||||
Solid fuel cogeneration boiler: [yes/no] | Combination boiler: [yes/no] | ||||||||||||
Fuel | Preferred fuel (only one): | Other suitable fuel(s): | ηs [x%]: | Seasonal space heating emissionsd | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PM | OGC | CO | NOx | ||||||||||
[x] mg/m3 | |||||||||||||
Log wood, moisture content ≤ 25 % | [yes/no] | [yes/no] | |||||||||||
Chipped wood, moisture content 15-35 % | [yes/no] | [yes/no] | |||||||||||
Chipped wood, moisture content > 35 % | [yes/no] | [yes/no] | |||||||||||
Compressed wood in the form of pellets or briquettes | [yes/no] | [yes/no] | |||||||||||
Sawdust, moisture content ≤ 50 % | [yes/no] | [yes/no] | |||||||||||
Other woody biomass | [yes/no] | [yes/no] | |||||||||||
Non-woody biomass | [yes/no] | [yes/no] | |||||||||||
Bituminous coal | [yes/no] | [yes/no] | |||||||||||
Brown coal (including briquettes) | [yes/no] | [yes/no] | |||||||||||
Coke | [yes/no] | [yes/no] | |||||||||||
Anthracite | [yes/no] | [yes/no] | |||||||||||
Blended fossil fuel briquettes | [yes/no] | [yes/no] | |||||||||||
Other fossil fuel | [yes/no] | [yes/no] | |||||||||||
Blended biomass (30-70 %)/fossil fuel briquettes | [yes/no] | [yes/no] | |||||||||||
Other blend of biomass and fossil fuel | [yes/no] | [yes/no] | |||||||||||
Characteristics when operating with the preferred fuel only: | |||||||||||||
Item | Symbol | Value | Unit | Item | Symbol | Value | Unit | ||||||
Useful heat output | Useful efficiency | ||||||||||||
At rated heat output | Pn c | x,x | kW | At rated heat output | ηn | x,x | % | ||||||
At [30 %/50 %] of rated heat output, if applicable | Pp | [x,x/N.A.] | kW | At [30 %/50 %] of rated heat output, if applicable | ηp | [x,x/N.A.] | % | ||||||
For solid fuel cogeneration boilers: Electrical efficiency | Auxiliary electricity consumption | ||||||||||||
At rated heat output | elmax | x,xxx | kW | ||||||||||
At rated heat output | ηel,n | x,x | % | At [30 %/50 %] of rated heat output, if applicable | elmin | [x,xxx/N.A.] | kW | ||||||
Of incorporated secondary emission abatement equipment, if applicable | [x,xxx/N.A.] | kW | |||||||||||
In standby mode | PSB | x,xxx | kW | ||||||||||
Contact details | Name and address of the manufacturer or its authorised representative. | ||||||||||||
Textual Amendments
Solid fuel boilers shall be tested for the preferred fuel and any other suitable fuels indicated in Table 1 of Annex II, with the exception that boilers tested for chipped wood with a moisture content of more than 35 % meeting the applicable requirements are considered to also meet such requirements for chipped wood with a moisture content of 15-35 % and are not required to be tested for chipped wood with a moisture content of 15-35 %.
Declared values for seasonal space heating energy efficiency and seasonal space heating emissions shall be rounded to the nearest integer.
Any solid fuel heat generator designed for a solid fuel boiler, and any solid fuel boiler housing to be equipped with such a heat generator, shall be tested with an appropriate solid fuel boiler housing and heat generator.
The useful efficiency values ηn , ηp and the useful heat output values Pn , Pp shall be measured, as appropriate. For solid fuel cogeneration boilers the electrical efficiency value ηel,n is also measured.
The seasonal space heating energy efficiency ηs shall be calculated as the seasonal space heating energy efficiency in active mode ηson , corrected by contributions accounting for temperature controls, auxiliary electricity consumption, and, for solid fuel cogeneration boilers, by adding the electrical efficiency multiplied by a conversion coefficient CC of 2,5.
The consumption of electricity shall be multiplied by a conversion coefficient CC of 2,5.
The seasonal space heating energy efficiency ηs is defined as:
ηs = ηson – F(1) – F(2) + F(3)
where:
ηson is the seasonal space heating energy efficiency in active mode expressed as a percentage, calculated as set out in point 4(b);
F(1) accounts for a loss of seasonal space heating energy efficiency due to adjusted contributions of temperature controls; F(1) = 3 %;
F(2) accounts for a negative contribution to the seasonal space heating energy efficiency by auxiliary electricity consumption, expressed as a percentage, and is calculated as set out in point 4(c);
F(3) accounts for a positive contribution to the seasonal space heating energy efficiency by the electrical efficiency of solid fuel cogeneration boilers, expressed as a percentage, and is calculated as follows:
F(3) = 2,5 × ηel,n
the seasonal space heating energy efficiency in active mode, ηson , is calculated as follows:
for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, and for automatically stoked solid fuel boilers:
ηson = 0,85 × ηp + 0,15 × ηn
for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, and for solid fuel cogeneration boilers:
ηson = ηn
F(2) is calculated as follows:
for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, and for automatically stoked solid fuel boilers:
F(2) = 2,5 × (0,15 × elmax + 0,85 × elmin + 1,3 × PSB )/(0,15 × Pn + 0,85 × Pp )
for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, and for solid fuel cogeneration boilers:
F(2) = 2,5 × (elmax + 1,3 × PSB)/Pn
The gross calorific value (GCV) shall be obtained from the gross calorific value moisture free (GCVmf ) by applying the following conversion:
GCV = GCVmf × (1 – M)
where:
GCV and GCVmf are expressed in megajoules per kilogram;
M is the moisture content of the fuel, expressed as a proportion.
Emissions of particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides shall be expressed standardised to a dry flue gas basis at 10 % oxygen and standard conditions at 0 °C and 1 013 millibar.
The seasonal space heating emissions Es of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides are calculated as follows:
for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, and for automatically stoked solid fuel boilers:
Es = 0,85 × Es,p + 0,15 × Es,n
for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, and for solid fuel cogeneration boilers:
Es = Es,n
where:
Es,p are the emissions of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides measured at 30 % or 50 % of rated heat output, as applicable;
Es,n are the emissions of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides measured at rated heat output.
Emissions of particulate matter shall be measured by a gravimetric method excluding any particulate matter formed by organic gaseous compounds when flue gas is mixed with ambient air.
Emissions of nitrogen oxides shall be calculated as the sum of nitrogen monoxide and nitrogen dioxide, and expressed in nitrogen dioxide.
Textual Amendments
F3Substituted by Commission Regulation (EU) 2016/2282 of 30 November 2016 amending Regulations (EC) No 1275/2008, (EC) No 107/2009, (EC) No 278/2009, (EC) No 640/2009, (EC) No 641/2009, (EC) No 642/2009, (EC) No 643/2009, (EU) No 1015/2010, (EU) No 1016/2010, (EU) No 327/2011, (EU) No 206/2012, (EU) No 547/2012, (EU) No 932/2012, (EU) No 617/2013, (EU) No 666/2013, (EU) No 813/2013, (EU) No 814/2013, (EU) No 66/2014, (EU) No 548/2014, (EU) No 1253/2014, (EU) 2015/1095, (EU) 2015/1185, (EU) 2015/1188, (EU) 2015/1189 and (EU) 2016/2281 with regard to the use of tolerances in verification procedures (Text with EEA relevance).
The verification tolerances defined in this Annex relate only to the verification of the measured parameters by [F4Great Britain] authorities and shall not be used by the manufacturer or importer as an allowed tolerance to establish the values in the technical documentation or in interpreting these values with a view to achieving compliance or to communicate better performance by any means.
Textual Amendments
F4Words in Annex 4 substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 27(10)(a) (as amended by S.I. 2020/1528, regs. 1(2), 6(1)(2)(b)(xxv)); 2020 c. 1, Sch. 5 para. 1(1)
[F5When verifying the compliance of a product model with the requirements laid down in this Regulation, for the requirements referred to in this Annex the authorities of Great Britain must apply the following procedure—]
Textual Amendments
F5Words in Annex 4 substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 27(10)(b) (as amended by S.I. 2020/1528, regs. 1(2), 6(3)(4)(b)(xxv)); 2020 c. 1, Sch. 5 para. 1(1)
The [F4Great Britain] authorities shall verify one single unit of the model.
The model shall be considered to comply with the applicable requirements if:
the values given in the technical documentation pursuant to [F6paragraph 1(2) of Part 1 of Schedule 1A to the Ecodesign for Energy-Related Products Regulations 2010], and, where applicable, the values used to calculate these values, are not more favourable for the manufacturer or importer than the results of the corresponding measurements carried out pursuant to [F7paragraph 1(2)(b)(vii) of Part 1 of Schedule 1A to those Regulations]; and
the declared values meet any requirements laid down in this Regulation, and any required product information published by the manufacturer or importer does not contain values that are more favourable for the manufacturer or importer than the declared values; and
when the [F4Great Britain] authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from these measurements) comply with the respective verification tolerances as given in Table 2. The unit shall be tested with one or more fuels with characteristics in the same range as the fuel(s) that were used by the manufacturer to perform the measurements described in Annex III.
If the results referred to in point 2(a) or (b) are not achieved, the model and all models that have been listed as equivalent models in the manufacturer's or importer's technical documentation shall be considered not to comply with this Regulation.
If the result referred to in point 2(c) is not achieved, the [F4Great Britain] authorities shall select three additional units of the same model for testing. As an alternative, the three additional units selected may be of one or more different models that have been listed as equivalent models in the manufacturer's or importer's technical documentation.
The model shall be considered to comply with the applicable requirements if, for these three units, the arithmetical mean of the determined values complies with the respective verification tolerances given in Table 2.
If the result referred to in point 5 is not achieved, the model and all models that have been listed as equivalent models in the manufacturer's or importer's technical documentation shall be considered not to comply with this Regulation.
F8...
Textual Amendments
F6Words in Annex 4 para. (2)(a) substituted (31.12.2020) by The Ecodesign for Energy-Related Products and Energy Information (Amendment) (EU Exit) Regulations 2019 (S.I. 2019/539), reg. 1(3), Sch. 2 para. 27(10)(c)(i); 2020 c. 1, Sch. 5 para. 1(1)
The [F4Great Britain] authorities shall use the measurement and calculation methods set out in Annex III.
The [F4Great Britain] authorities shall only apply the verification tolerances that are set out in Table 2 and shall only use the procedure described in points 1 to [F96] for the requirements referred to in this Annex. No other tolerances, such as those set out in [F10designated] standards or in any other measurement method, shall be applied.
Textual Amendments
Verification tolerances
Parameters | Verification tolerance |
---|---|
Seasonal space-heating energy efficiency, η s | The determined value shall not be lower than the declared value by more than 4 %. |
Emissions of particulate matter | The determined value shall not exceed the declared value by more than 9 mg/m 3 . |
Emissions of organic gaseous compounds | The determined value shall not exceed the declared value by more than 7 mg/m 3 . |
Emissions of carbon monoxide | The determined value shall not exceed the declared value by more than 30 mg/m 3 . |
Emissions of nitrogen oxides | The determined value shall not exceed the declared value by more than 30 mg/m 3 .] |
The indicative benchmarks for the best available technology on the market for solid fuel boilers at the time of entry into force of this Regulation are as follows. At the time of entry into force of this Regulation, no single solid fuel boiler was identified meeting all the values specified in points 1 and 2. Several solid fuel boilers met one or more of these values:
For seasonal space heating energy efficiency: 96 % for solid fuel cogeneration boilers, 90 % for condensing boilers and 84 % for other solid fuel boilers.
For seasonal space heating emissions:
2 mg/m3 for particulate matter for biomass boilers; 10 mg/m3 for fossil fuel boilers;
1 mg/m3 for organic gaseous compounds;
6 mg/m3 for carbon monoxide;
97 mg/m3 for nitrogen oxides for biomass boilers; 170 mg/m3 for fossil fuel boilers.
The benchmarks specified in points 1 and 2(a) to (d) do not necessarily imply that a combination of those values is achievable for a single solid fuel boiler. An example of a good combination is an existing model with a seasonal space heating energy efficiency of 81 % and seasonal space heating emissions of particulate matter of 7 mg/m3, of organic gaseous compounds of 2 mg/m3, of carbon monoxide of 6 mg/m3 and of nitrogen oxides of 120 mg/m3.
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i mabwysiadwyd gan yr UE): Mae'r wreiddiol version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
Mae’r llinell amser yma yn dangos y fersiynau gwahanol a gymerwyd o EUR-Lex yn ogystal ag unrhyw fersiynau dilynol a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig.
Cymerir dyddiadau fersiynau’r UE o ddyddiadau’r dogfennau ar EUR-Lex ac efallai na fyddant yn cyfateb â’r adeg pan ddaeth y newidiadau i rym ar gyfer y ddogfen.
Ar gyfer unrhyw fersiynau a grëwyd ar ôl y diwrnod ymadael o ganlyniad i newidiadau a wnaed gan ddeddfwriaeth y Deyrnas Unedig, bydd y dyddiad yn cyd-fynd â’r dyddiad cynharaf y daeth y newid (e.e. ychwanegiad, diddymiad neu gyfnewidiad) a weithredwyd i rym. Am ragor o wybodaeth gweler ein canllaw i ddeddfwriaeth ddiwygiedig ar Ddeall Deddfwriaeth.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys