Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
Statutory Instruments
WEIGHTS AND MEASURES
Made
28th April 2006
Laid before Parliament
8th May 2006
Coming into force
Regulations 1, 2, 7, 9 and 10 and Part 1 of Schedule 2
30th May 2006
Remaining regulations
30th October 2006
The Secretary of State is a Minister designated M1 for the purposes of section 2(2) of the European Communities Act 1972 M2 in relation to, and for purposes ancillary to, the regulation of specifications, construction, placing on the market and use of articles, instruments, containers or other equipment intended for weighing, measuring or testing.
The Secretary of State makes the following Regulations under the powers conferred on him by section 2(2) of that Act and, in relation to Part III of the Regulations, under the powers conferred on him by sections 15(1) and 86(1) of the Weights and Measures Act 1985 M3.
1.—(1) These Regulations may be cited as the Measuring Instruments (Liquid Fuel and Lubricants) Regulations 2006.
(2) This regulation, regulations 2, 7, 9 and 10 and Part 1 of Schedule 2 shall come into force on 30th May 2006.
(3) The remaining regulations shall come into force on 30th October 2006.
2.—(1) In these Regulations—
“accuracy class” means the classification of a measuring system determined in accordance with paragraph 19 of Schedule 1;
“authorised representative” means a person who is established in a member State and is authorised by a manufacturer, in writing, to act on his behalf;
“CE marking” means the CE marking referred to in regulation 12;
“the Commission” means the European Commission;
“compliance notice” means a notice served in accordance with regulation 18(2);
“conformity assessment procedure” means any procedure referred to in regulation 6;
“the Directive” means Directive 2004/22/EC of the European Parliament and of the Council of 31st March 2004 on measuring instruments M4;
“disqualification mark” means a mark or sticker the design of which is published by the Secretary of State and which is affixed to a measuring system in accordance with regulation 21;
“enforcement authority” means any person who is, pursuant to regulation 17, authorised to enforce these Regulations;
“enforcement notice” means a notice served in accordance with regulation 19(2);
“enforcement officer” means—
means an inspector; or
a person appointed by the Secretary of State to act on his behalf to enforce Part II of these Regulations;
“essential requirements” means the requirements set out in Schedule 1;
“flowrate range” means the range between the minimum flowrate and the maximum flowrate;
“harmonised standard” means a technical specification adopted by the European Committee for Standardisation (CEN), the European Committee for Electrotechnical Standardisation (CENELEC) or the European Telecommunications Standards Institute (ETSI) or jointly by two or all of these organisations, at the request of the Commission pursuant to Directive 98/34/EC of the European Parliament and of the Council of 22nd June 1998 laying down a procedure for the provision of information in the field of technical standards and regulations and of rules on Information Society Services M5, as amended by Directive 98/48/EC M6, and prepared in accordance with the General Guidelines agreed between the Commission and one or more of CEN, CENELEC and ETSI;
“instrument” has the same meaning as measuring system;
“in writing” includes text that is—
transmitted by electronic means;
received in legible form; and
capable of being used for subsequent reference;
“liquid fuel” includes lubricants and any mixture of liquid fuel and lubricants;
“M marking” means the M marking referred to in regulation 12;
“manufacturer” means a person responsible for the conformity of a measuring system with these Regulations with a view to either placing it on the market under his own name or putting it into use for his own purposes, or both;
“maximum permissible error” means, in the case of a measuring system—
when it is used for trade, the limit of error determined in accordance with regulation 15 and Schedule 5; and
when it is placed on the market or put into use, the limit of error determined in accordance with paragraph 16 of Schedule 1;
“measuring system” means a system that comprises the meter and all devices required to ensure correct measurement or intended to facilitate the measuring operations;
“meter” means equipment designed to measure continuously, memorise and display the quantity at metering conditions of liquid fuel flowing through the measurement transducer in a closed, fully charged circuit;
“minimum measured quantity” means the smallest quantity of liquid fuel for which the measurement is metrologically acceptable for the measuring system;
“normative document” means a document containing technical specifications adopted by the Organisation Internationale de Métrologie Légale, subject to the procedure stipulated in Article 16.1, the reference of which is published by the Commission in the Official Journal of the European Union pursuant to Article 16.1(b);
“notified body” means—
the Secretary of State; or
a United Kingdom notified body; and
for the purposes of regulations 4(1)(c), 19(1)(b), 21(1)(c) and 24(6), a person designated by another member State,
who has been notified to the Commission and the other member States pursuant to Article 11.1;
“notified body criteria” means the criteria set out in Part 1 of Schedule 2;
“place on the market” means making available for the first time in a member State an instrument intended for an end user, whether for reward or free of charge;
“put into use” means the first use of an instrument intended for the end user for the purposes for which it was intended;
“relevant national standard” means a standard applicable to an instrument—
implementing a harmonised standard that has been published in the Official Journal of the European Union C series; and
the reference of which is published—
in the United Kingdom by the Secretary of State; or
in another member State by the competent authority pursuant to the third sub-paragraph of Article 13.1;
“relevant normative document” means a normative document applicable to an instrument, the reference of which is published—
in the United Kingdom by the Secretary of State; or
in another member State by the competent authority pursuant to the third sub-paragraph of Article 13.2;
“re-qualification mark” means a mark or sticker the design of which is published by the Secretary of State and which is affixed to a measuring system in accordance with regulation 22;
“sealing device” means a seal or a plug; and
“United Kingdom notified body” means a person designated under regulation 7.
(2) Other expressions used in these Regulations have the same meanings as in the Weights and Measures Act 1985.
(3) In these Regulations, a reference to a member State includes Norway, Iceland and Liechtenstein M7.
(4) References in these Regulations to an Article, Annex or a part of Annex are references to an Article, Annex or a part of an Annex to the Directive.
Marginal Citations
M4OJ No. L135, 30.4.04, p.1.
M5OJ No. L204, 21.7.98, p.37.
M6OJ No. L217, 5.8.98, p.18.
M7The application of the Directive was extended to the European Economic Area by Decision No. 31/2005 (OJ No. L198, 28.7.05, p.20).
3.—(1) Subject to paragraphs (2), (3), (4) and (5), these Regulations apply to a measuring system which is—
(a)for use for trade in the making of a continuous and dynamic measurement of liquid fuel in a quantity equal to or less than 100 litres or 100 kilograms; and
(b)first placed on the market or put into use on or after 30th October 2006.
(2) These Regulations do not apply to a measuring system—
(a)in respect of which a certificate of approval has been granted before 30th October 2006 and is in force; and
(b)which is first passed as fit for use for trade and stamped under the Measuring Equipment (Liquid Fuel and Lubricants) Regulations 1995 M8.
(3) These Regulations do not apply to a measuring system—
(a)in respect of a pattern of which EEC pattern approval was granted before 30th October 2006 and is in force; and
(b)which bears a mark of EEC initial verification or of EEC partial verification.
(4) These Regulations do not apply to a measuring system which is used to measure liquefied petroleum gas or liquefied natural gas.
(5) These Regulations do not apply to a measuring system which is not compliant with the essential requirements and which is displayed or presented at a trade fair, exhibition or demonstration, if a sign displayed visibly on or near the instrument clearly indicates that the instrument—
(a)is not compliant with those requirements; and
(b)cannot be acquired or used until it is made compliant with those requirements by the manufacturer.
(6) For the purposes of paragraph (3)—
(a)a grant of EEC pattern approval or the affixing of a mark of EEC initial verification shall be in accordance with the Measuring Instruments (EEC Requirements) Regulations 1988 M9 (“the 1988 Regulations”) or, in the case of any other member State, in accordance with the measures in force which implement—
(i)Council Directive 71/319/EEC M10;
(ii)Council Directive 71/348/EEC M11, as amended by the Treaty of Accession 1994 M12; and
(iii)Council Directive 77/313/EEC M13, as amended by Commission Directive 82/625/EEC M14; and
(b)the affixing of a mark of EEC partial verification shall be in accordance with the 1988 Regulations, or in the case of any other member State, in accordance with the measures in force which implement Council Directive 71/316/EEC M15, as amended by Council Directives 72/427/EEC M16, 83/575/EEC M17, 87/354/EEC M18, 87/355/EEC M19 and 88/665/EEC M20.
4.—(1) No person shall place on the market or put into use a measuring system unless the following requirements, or the corresponding requirements of the Directive as implemented under the law of another member State, are met—
(a)the instrument is compliant with the essential requirements;
(b)the manufacturer has demonstrated its compliance with the essential requirements in accordance with regulation 5; and
(c)the instrument has affixed to it the CE marking, the M marking and the identification number of the notified body which carried out the conformity assessment procedure in respect of the instrument.
(2) A person who fails to comply with the requirements of paragraph (1) shall be guilty of an offence and any measuring system to which the offence relates shall be liable to be forfeited.
5.—(1) A manufacturer may demonstrate that a measuring system is compliant with the essential requirements by—
(a)using any technical solution that is compliant with the essential requirements;
(b)correctly applying solutions set out in the relevant national standard; or
(c)correctly applying solutions set out in the relevant normative document,
and selecting and following one of the conformity assessment procedures.
(2) A measuring system which is compliant with the relevant national standard or relevant normative document shall be presumed to be compliant with the essential requirements.
(3) Where the measuring system is compliant only in part with the relevant national standard or relevant normative document, it shall be presumed to be compliant only with that part of the essential requirements which corresponds to the element of the relevant national standard or relevant normative document with which the instrument is compliant.
(4) Where a measuring system includes or is connected to a device which is not used for trade—
(a)that device shall not be subject to the essential requirements; and
(b)the instrument may be considered to be compliant with the essential requirements notwithstanding that the compliance of that device with the essential requirements has not been established.
6.—(1) The conformity assessment procedures are the procedures as follows—
(a)B and D;
(b)B and F;
(c)G; or
(d)H1.
(2) The manufacturer or his authorised representative shall provide to the notified body carrying out the relevant conformity assessment procedure the technical documentation set out in Schedule 3.
(3) In this regulation—
(a)“B” means type examination, set out in Annex B;
(b)“D” means declaration of conformity to type based on quality assurance of the production process, set out in Annex D;
(c)“F” means declaration of conformity to type based on product verification, set out in Annex F;
(d)“G” means declaration of conformity based on unit verification, set out in Annex G; and
(e)“H1” means declaration of conformity based on full quality assurance plus design examination, set out in Annex H1.
7.—(1) The Secretary of State may, on the application of a person, designate that person to be a United Kingdom notified body.
(2) The Secretary of State shall not make a designation under paragraph (1) unless he is satisfied that the person meets the notified body criteria.
(3) A person who meets the criteria laid down in a national standard shall be presumed to meet that part of the notified body criteria which corresponds to the criteria in the national standard.
(4) A designation under paragraph (1)—
(a)shall be in writing;
(b)may be made subject to such conditions as may be specified in the designation, which may include conditions which—
(i)are to apply upon or following termination of the designation;
(ii)require the use of test equipment for the purpose of conformity assessment appropriate to the measuring system being assessed; and
(iii)limit the description of any measuring system for which the person is designated;
(c)subject to regulation 10, may last for such period as may be specified in the designation;
(d)shall specify the conformity assessment procedures and specific tasks (which may be framed by reference to any circumstances) which the person has been designated to carry out; and
(e)may include a requirement to publish from time to time the scale of fees which the person charges pursuant to regulation 11 or such information about the basis of calculation of such fees as may be specified.
(5) In exercising the power conferred on him by paragraph (1), the Secretary of State may (in addition to the matters of which he is required to satisfy himself pursuant to paragraph (2)) have regard to any matter appearing to him to be relevant.
(6) For the purposes of paragraph (3), “national standard” means a standard applicable to the designation of notified bodies—
(a)implementing a harmonised standard that has been published in the Official Journal of the European Union; and
(b)the reference of which is published—
(i)in the United Kingdom by the Secretary of State; or
(ii)in another member State by the competent authority pursuant to Article 11.2.
8. A notified body shall carry out the functions set out in Part 2 of Schedule 2.
9.—(1) The Secretary of State shall, from time to time, publish a list of notified bodies indicating, in the case of each United Kingdom notified body, the description of any measuring system in respect of which that notified body is designated; and such a list may include information concerning any condition to which the designation of any United Kingdom notified body is subject.
(2) The Secretary of State shall, from time to time, carry out an inspection of each United Kingdom notified body with a view to verifying that it—
(a)meets the notified body criteria;
(b)complies with any condition to which its designation is subject; and
(c)complies with these Regulations,
but, unless it appears to him that there are circumstances which make it necessary or expedient to do so, he shall not carry out an inspection within two years from the date of designation under regulation 7, or of any later inspection under this paragraph.
10.—(1) The Secretary of State may vary a designation made under regulation 7 if—
(a)the United Kingdom notified body so requests; or
(b)it appears to him necessary or expedient to do so.
(2) The Secretary of State may terminate a designation made under regulation 7—
(a)on the expiry of 90 days' notice in writing at the request of the United Kingdom notified body;
(b)if it appears to him that any condition of the designation is not complied with; or
(c)if in his opinion the United Kingdom notified body ceases to satisfy the notified body criteria.
(3) Where the Secretary of State is minded to—
(a)vary a designation pursuant to paragraph (1)(b); or
(b)terminate a designation pursuant to paragraph (2)(b) or (c),
he shall—
(i)give notice in writing to the United Kingdom notified body of his reasons; and
(ii)give that notified body the opportunity to make representations within a period of 21 days from the date of that notice and consider any representations made to him within that period.
(4) If a designation is terminated under paragraph (2), the Secretary of State may—
(a)give such directions (either to the United Kingdom notified body the subject of the termination or to another United Kingdom notified body) for the purposes of making arrangements for the determination of outstanding applications as he considers appropriate; and
(b)notwithstanding sub-paragraph (a), authorise another United Kingdom notified body to take over the functions of the United Kingdom notified body the subject of the termination in respect of such cases as he may specify.
11.—(1) A United Kingdom notified body may charge such fees in connection with, or incidental to, the carrying out of conformity assessment procedures or specific tasks as it may determine.
(2) The fees referred to in paragraph (1) shall not exceed the following—
(a)the costs incurred or to be incurred by the United Kingdom notified body in performing the relevant function; and
(b)an amount on account of profit which is reasonable in the circumstances having regard to—
(i)the character and extent of the work done or to be done by that notified body on behalf of the applicant; and
(ii)the commercial rate normally charged on account of profit for that work or similar work.
(3) The power in paragraph (1) includes the power to require the payment of fees or a reasonable estimate of such fees in advance of carrying out the work requested by the applicant.
(4) Where any fees payable to a United Kingdom notified body pursuant to this regulation remain unpaid 28 days after either the work has been completed or payment of the fees has been requested in writing, whichever is the later, that notified body may by 14 days' notice in writing provide that, unless the fees are paid before the expiry of the notice, the certificate or notification appropriate to the relevant conformity assessment procedure may be suspended until payment of the fees has been received.
12.—(1) Where a measuring system is compliant with the essential requirements—
(a)the manufacturer shall affix the CE marking and the M marking to the instrument; and
(b)the notified body which carries out the conformity assessment procedure in respect of that instrument shall affix its identification number to the instrument, or may agree that the manufacturer shall do so on its behalf.
(2) Any other marking may be affixed to a measuring system provided that the visibility and legibility of the CE marking, the M marking and the identification number of the notified body are not reduced.
(3) For the purposes of paragraph (1)—
(a)the CE marking means the symbol “CE” which shall be compliant with the requirements of paragraphs 1, 4 and 5 of Schedule 4;
(b)the M marking means the capital letter “M” which shall be compliant with the requirements of paragraphs 2, 4 and 5 of Schedule 4; and
(c)the identification number of the notified body shall be compliant with the requirements of paragraphs 3, 4 and 5 of Schedule 4.
13.—(1) Where a measuring system falls within the scope of other directives which provide for the affixing of the CE marking, the affixing of the CE marking under these Regulations shall indicate that the instrument is also presumed to be compliant with the requirements of those other directives.
(2) Where paragraph (1) applies, the publication reference of such other directives in the Official Journal of the European Union must be given in the documents, notices or instructions required to accompany the instrument.
14. No person shall use for trade a measuring system unless—
(a)it is compliant with the essential requirements other than the provisions relating to maximum permissible errors referred to in paragraph 16 of Schedule 1;
(b)it is so positioned as to facilitate testing;
(c)it operates within the maximum permissible errors in regulation 15; and
(d)the requirements of regulation 16 are complied with.
15.—(1) In the case of a measuring system used to measure a quantity of liquid fuel—
(a)above the minimum measured quantity of the instrument, the maximum permissible error shall be determined in accordance with Table 1 in Schedule 5; and
(b)equal to the minimum measured quantity of the instrument, the maximum permissible error shall be determined in accordance with Table 2 in Schedule 5.
(2) But the maximum permissible error for a quantity above the minimum measured quantity of the instrument shall not be less than the maximum permissible error for a quantity equal to the minimum measured quantity.
(3) Where the instrument falls within an accuracy class of 0.3, 0.5, 1.0, 1.5 or 2.5, it shall, for a quantity set out in column 1 of the relevant Table, operate within the maximum permissible error set out in column 2, 3, 4, 5 or 6 of that Table for that class and that quantity.
16.—(1) Where a measuring system is marked with—
(a)a temperature range, it shall not be used for trade in temperatures outside that range;
(b)a flowrate range, it shall not be used for trade at a flowrate outside that range.
(2) A measuring system shall not be used for trade unless it is marked in a manner which is sufficiently clear to enable the buyer to identify the product which that instrument delivers but this paragraph shall not apply where the instrument is used in the absence of the buyer.
(3) A measuring system shall not be used for trade in circumstances which are likely prematurely to degrade its metrological characteristics.
(4) A measuring system shall not be used for trade unless the sales indicator—
(a)is set to zero before measurement of the liquid fuel commences;
(b)remains at zero until that fuel starts to emerge from the instrument;
(c)is not reset to zero during measurement of that fuel; and
(d)cannot be advanced by any means other than by the discharge of that fuel from the instrument and the proper operation of the instrument.
(5) If a measuring system is adjusted, it shall not be used for trade unless the calibration of the instrument is set as close to zero error as is practicable.
(6) Where a measuring system used for trade bears a mark (other than a mark referred to in paragraph (1)) which signifies the manner and purpose of use, that instrument shall not be used in a manner or for a purpose which does not accord with that marking.
(7) A measuring system shall not be used in circumstances in which it may be prevented from operating consistently or accurately.
(8) Nothing in paragraphs (6) or (7) shall prevent the use for trade of an instrument where a buyer chooses to take a delivery which is less than the minimum measured quantity.
17.—(1) It shall be the duty of every local weights and measures authority to enforce these Regulations within its area.
(2) The Secretary of State may enforce Part II of these Regulations and for that purpose may appoint any person to act on his behalf.
(3) No proceedings for an offence under these Regulations may be instituted in England and Wales except by or on behalf of an enforcement authority.
(4) Nothing in these Regulations shall authorise an enforcement authority to bring proceedings in Scotland for an offence.
18.—(1) Where an enforcement authority establishes that, in the case of a measuring system that has been placed on the market or put into use, the CE marking or the M marking has, or both have, been affixed unduly, the following provisions of this regulation shall have effect.
(2) The enforcement authority shall serve a compliance notice on the manufacturer or his authorised representative which shall—
(a)be in writing;
(b)describe the measuring system to which it relates in a manner sufficient to identify that instrument;
(c)state that the enforcement authority is of the opinion that the CE marking or the M marking has, or both have, been affixed unduly to the measuring system and give reasons for its opinion;
(d)require the person on whom the notice is served to end the infringement under conditions specified in the notice;
(e)specify the date, being not less than 21 days from the date of the notice, by which the infringement must be ended; and
(f)warn that person that, where the non-conformity continues beyond the date specified in sub-paragraph (e), the enforcement authority may take further action under regulation 19 in respect of that instrument.
(3) For the purposes of paragraph (1)—
(a)the CE marking shall be considered to have been affixed unduly if it is not compliant with the requirements of regulation 12(3)(a); and
(b)the M marking shall be considered to have been affixed unduly if it is not compliant with the requirements of regulation 12(3)(b).
(4) Where a compliance notice is served by an enforcement authority other than the Secretary of State, it shall, at the same time as it serves that notice, send a copy to the Secretary of State.
19.—(1) Where an enforcement authority has reasonable grounds for considering that—
(a)the manufacturer or his authorised representative has failed to comply with a compliance notice;
(b)a measuring system, which is placed on the market or put into use, does not bear one or more of the CE marking, the M marking and the identification number of the notified body which carried out the conformity assessment procedure in respect of that instrument; or
(c)a measuring system which bears the marking and identification requirements referred to in sub-paragraph (b) does not meet the essential requirements when placed on the market, or properly installed and put into use in accordance with the manufacturer's instructions,
the following provisions of this regulation shall have effect.
(2) The enforcement authority shall serve an enforcement notice on the manufacturer or his authorised representative which shall—
(a)be in writing;
(b)describe the measuring system to which it relates in a manner sufficient to identify that instrument;
(c)specify, with reasons, the respects in which, in the opinion of the enforcement authority, the requirements of these Regulations have not been complied with;
(d)specify the date, being not less than 21 days from the date of the notice, by which the person to whom the notice is given is required to comply with it; and
(e)inform that person of the judicial remedies available to him and of the time limits to which those remedies are subject.
(3) A notice under paragraph (2) may—
(a)require the measuring system to be withdrawn from the market; or
(b)prohibit or restrict the placing on the market or putting into use of the measuring system; and
(c)specify that unless steps are taken which ensure—
(i)that the measuring system is compliant with the requirements of these Regulations; or
(ii)that the manufacturer or his authorised representative acts as required under sub-paragraph (a) or (b),
any certificate or notification, issued by a notified body in accordance with the relevant conformity assessment procedure applicable to the instrument that the instrument satisfies the essential requirements, may be withdrawn by that notified body.
(4) Where an enforcement notice is served by an enforcement authority other than the Secretary of State, it shall, at the same time as it serves that notice, send a copy to the Secretary of State.
(5) In the case of a certificate or notification referred to in paragraph (3)—
(a)which is granted by a United Kingdom notified body, if the Secretary of State is of the opinion that consideration ought to be given to whether the certificate or notification should be withdrawn, he shall inform that notified body of that fact; and
(b)which is granted under the law of another member State, if the Secretary of State is of the opinion that consideration ought to be given to whether the certificate or notification should be withdrawn, he shall inform the relevant competent authority of that fact.
20.—(1) Where a person is aggrieved by a compliance notice or an enforcement notice served by an enforcement authority other than the Secretary of State, that person may apply to the Secretary of State to review such notice.
(2) An application under paragraph (1) shall—
(a)be in writing;
(b)state the grounds on which the application is made; and
(c)be sent to the Secretary of State within 21 days from the date of the notice referred to in paragraph (1).
(3) The Secretary of State may—
(a)hold an inquiry in connection with the notice which is the subject of his review; and
(b)appoint an assessor for the purposes of assisting him with his review.
(4) The Secretary of State shall, within a reasonable time, inform the aggrieved person and the enforcement authority referred to in paragraph (1) in writing of his decision whether to uphold the notice served by that authority, together with reasons for his decision.
(5) Where the Secretary of State does not uphold any notice referred to in paragraph (1), he shall give instructions for the withdrawal of that notice.
21.—(1) If it appears to an inspector that a measuring system which bears—
(a)the CE marking;
(b)the M marking; and
(c)the identification number of the notified body which carried out the conformity assessment procedure in respect of the instrument,
is used for trade in circumstances where—
(i)the instrument is no longer compliant with one or more of the requirements of regulation 14; or
(ii)by reason of any adjustment, alteration, addition, repair or replacement it is likely that the instrument has ceased to be compliant with one or more of the requirements of regulation 14,
the inspector may affix a disqualification mark to the instrument or to any sealing device on that instrument.
(2) Where one or more of the markings and identification requirements referred to in paragraph (1) is not affixed to a measuring system, the inspector may affix a disqualification mark to the instrument or to any sealing device on it.
(3) Where it appears to the inspector that the nature or degree of non-compliance of the measuring system under paragraph (1) is not such that a disqualification mark should be immediately affixed to it or to any sealing device on it, he may give to any person in possession of the instrument a notice requiring that person to rectify the non-compliance before the expiry of a stated period not less than 14 days and not exceeding 28 days from the date of the notice.
(4) If a notice given under paragraph (3) is not complied with, the inspector shall affix a disqualification mark to the measuring system or to any sealing device on it.
(5) A disqualification mark which is affixed to a measuring system shall be affixed in such a position that it is clearly visible when the instrument is in its regular operating position or where it is affixed to any sealing device on the instrument, it shall be affixed in such a position that it obliterates as far as possible any inscription on that sealing device.
(6) A person shall be guilty of an offence if he uses for trade a measuring system to which there is affixed a disqualification mark, unless a re-qualification mark has been affixed to the instrument in accordance with regulation 22.
22.—(1) Where—
(a)a disqualification mark has been affixed to a measuring system or to any sealing device on it in accordance with regulation 21(1), 21(2) or 21(4);
(b)a notice has been served under regulation 21(3); or
(c)a measuring system intended to be used for trade in the circumstances referred to in regulation 21(1)(i) or (ii), or 21(2) but a disqualification mark has not been affixed to the instrument or to any sealing device on it,
a person requiring a re-qualification mark to be affixed to the instrument or to any sealing device on it shall submit it, in such manner as may be directed, to an inspector or approved verifier and provide such assistance as the inspector or approved verifier may reasonably require.
(2) An inspector or approved verifier may affix a re-qualification mark to that measuring system or to any sealing device on it if satisfied that the instrument is compliant with—
(a)the essential requirements; and
(b)the requirements of regulation 14(b) and (d).
(3) For the purposes of being satisfied that a re-qualification mark may be affixed to a measuring system or to any sealing device on it, an inspector or approved verifier may take such steps as he considers appropriate, including testing the instrument by means of such test equipment as he considers appropriate and suitable for the purpose.
(4) There may be charged in respect of any steps taken under paragraph (3)—
(a)by an inspector, such reasonable fees as the local weights and measures authority may determine; and
(b)by an approved verifier, such reasonable fees as he may determine,
having regard to the character and extent of the work done or to be done.
(5) The inspector or approved verifier shall keep a record of any test carried out under paragraph (3).
(6) Where a re-qualification mark is affixed to a measuring system pursuant to paragraph (2), it shall be affixed in such a position that it obliterates as far as possible any disqualification mark.
23.—(1) Where an inspector considers that a test of a measuring system is necessary, otherwise than for the purposes of regulation 22(3), he may require the person who has control of the instrument, or whom he has reasonable cause to believe has control of the instrument (“the controller”), to provide to him such equipment, test liquid, materials, qualified personnel or other assistance as the inspector may reasonably require.
(2) No measuring system shall be tested until it is installed ready for use and complete with all its parts.
(3) A measuring system shall be tested by an inspector under practical working conditions with a test liquid which shall be—
(a)the liquid fuel that the instrument is intended to deliver; or
(b)a liquid having properties which replicate in all respects relevant to testing those of the liquid fuel that the instrument is intended to deliver.
(4) An inspector may open a locked or sealed tank or container for the purpose of testing a measuring system or returning any liquid withdrawn during testing.
(5) Any liquid withdrawn during testing shall be—
(a)returned to the tank or container from which it was withdrawn if the inspector is of the opinion that it is reasonable and practicable to do so and the controller agrees; or
(b)placed in another suitable receptacle reasonably convenient for the purpose that is provided by the controller.
(6) An inspector, if requested to do so by the controller, shall give to him a signed and dated statement of the quantity of liquid withdrawn during testing.
(7) An inspector shall—
(a)securely re-fasten any tank or container opened under paragraph (4) immediately after the conclusion of any test or after returning any liquid withdrawn during testing;
(b)replace any sealing device broken by him; and
(c)affix to that replaced sealing device a marking, the design of which shall be published by the Secretary of State.
24.—(1) Subject to paragraph (2), a person shall be guilty of an offence if, in the case of a measuring system, he—
(a)affixes an authorised mark to the instrument otherwise than in accordance with these Regulations;
(b)alters or defaces an authorised mark affixed to the instrument;
(c)removes an authorised mark affixed to the instrument; or
(d)affixes any other marking to the instrument which is likely to deceive any person as to the meaning or form, or both, of an authorised mark.
(2) Where the alteration or defacement of an authorised mark is occasioned solely—
(a)in the course of the adjustment or repair of a measuring system by a person regularly engaged in the business of repair of such instruments, or by his authorised agent; or
(b)by an enforcement officer or approved verifier in the carrying out of any of his functions under these Regulations,
that person or his authorised agent, enforcement officer or approved verifier shall not be guilty of an offence under paragraph (1)(b).
(3) A person shall be guilty of an offence if he places on the market, puts into use or uses for trade a measuring system—
(a)which, to his knowledge, bears—
(i)an authorised mark affixed otherwise than in accordance with these Regulations;
(ii)an authorised mark that has been altered or defaced otherwise than in the circumstances referred to in paragraph (2);
(iii)any marking which is likely to deceive any person as to the meaning or form, or both, of an authorised mark; or
(b)from which, to his knowledge, an authorised mark has been removed.
(4) A measuring system in respect of which an offence under this regulation has been committed and any implement used in the commissioning of the offence shall be liable to be forfeited.
(5) A reference in this regulation to other provisions of these Regulations includes a reference to corresponding provisions under the laws of other member States.
(6) In this regulation, “authorised mark” means the CE marking, the M marking, the identification number of the notified body which carried out the conformity assessment procedure in respect of the instrument, disqualification mark or re-qualification mark.
25.—(1) Subject to the production if so requested of his credentials, an enforcement officer may for the purposes of these Regulations, at all reasonable times—
(a)inspect and test any measuring system in such manner as he considers appropriate;
(b)inspect and take copies of any document relating to a measuring system; and
(c)enter any premises at which he has reasonable cause to believe there to be a measuring system, not being premises used only as a private dwelling house.
(2) Subject to the production if so requested of his credentials, an enforcement officer may, at any time, seize and detain—
(a)a measuring system which he has reasonable cause to believe is liable to be forfeited under these Regulations; and
(b)any document or goods which he has reason to believe may be required as evidence in proceedings for an offence under these Regulations.
(3) If a justice of the peace, on written information on oath—
(a)is satisfied that there are reasonable grounds to believe that any measuring system or document as is mentioned in paragraph (1) or (2) is on any premises, or that an offence under these Regulations has been, is being or is about to be committed on any premises; and
(b)is also satisfied either that—
(i)admission to the premises has been or is likely to be refused, and that notice of intention to apply for a warrant has been given to the occupier; or
(ii)an application for admission, or the giving of such a notice would defeat the object of the entry, or that the case is one of urgency, or that the premises are unoccupied or the occupier is temporarily absent,
the justice may by warrant under his hand, which shall continue in force for a period of one month, authorise the enforcement officer to enter the premises, if need be by force.
(4) In the application of paragraph (3) to Scotland, “justice of the peace” includes a sheriff and references to written information on oath shall be construed as references to evidence on oath.
(5) An enforcement officer entering any premises by virtue of this regulation may take such other persons and such equipment as may appear to him necessary, and on leaving such premises which he has entered by virtue of a warrant under paragraph (3), being premises which are unoccupied or the occupier of which is temporarily absent, he shall leave them as effectively secured against a trespasser as he found them.
(6) If an enforcement officer or other person who enters any work-place by virtue of this regulation discloses to any person any information obtained by him in the work-place with regard to any secret manufacturing process or trade secret, he shall, unless the disclosure was made in the performance of his duty, be guilty of an offence.
(7) It shall not be an offence under paragraph (6) for a person to disclose information in circumstances where—
(a)the person from whom the information was received has consented to its disclosure; or
(b)the information is disclosed more than 50 years after it was received.
(8) Nothing in this regulation shall authorise any person to stop any vehicle on a highway.
(9) In this regulation, “credentials” means evidence of appointment or designation as an enforcement officer.
26.—(1) A person shall be guilty of an offence if he—
(a)wilfully obstructs an enforcement officer in the execution of any of his functions under these Regulations; or
(b)without reasonable cause fails to give that officer any assistance or information which the officer has reasonably required of him for the purpose of the performance by the enforcement authority of its functions under these Regulations.
(2) A person shall be guilty of an offence if, in giving an enforcement officer such information as is mentioned in paragraph (1)(b), that person gives any information which he knows to be false.
27. A person guilty of an offence under Part II or Part IV shall be liable, on summary conviction, to a fine not exceeding level 5 on the standard scale.
28.—(1) Subject to the following provisions of this regulation, in proceedings against a person for an offence under these Regulations, it shall be a defence for that person to show that he took all reasonable steps and exercised all due diligence to avoid committing the offence.
(2) Where, in proceedings against a person for such an offence, the defence provided by paragraph (1) involves an allegation that the commission of the offence was due to—
(a)the act or default of another; or
(b)reliance on information given by another,
that person shall not, without the leave of the court, be entitled to rely on the defence, unless, not less than seven clear days before the hearing of the proceedings (or, in Scotland, the trial diet), he has served a notice in accordance with paragraph (3) on the person bringing the proceedings.
(3) A notice under this regulation shall give such information identifying or assisting in the identification of the person who committed the act or default or gave the information as is in the possession of the person serving the notice at the time he serves it.
(4) A person shall not be entitled to rely on the defence provided by paragraph (1) by reason of his reliance on information supplied by another, unless he shows it was reasonable in all the circumstances for him to have relied on the information, having regard in particular to—
(a)the steps which he took, and those which might reasonably have been taken, for the purpose of verifying the information; and
(b)whether he had any reason to disbelieve the information.
29.—(1) Where the commission by a person of an offence under these Regulations is due to the act or default of another person in the course of any business of his, that other person shall be guilty of the offence and may be proceeded against and punished, whether or not proceedings are taken against the first person.
(2) Where a body corporate commits an offence and it is proved that the offence was committed—
(a)with the consent or connivance of an officer of the body corporate; or
(b)as a result of the negligence of an officer of the body corporate,
the officer, as well as the body corporate, shall be guilty of the offence.
(3) In paragraph (2), a reference to an officer of a body corporate includes a reference to—
(a)a director, manager, secretary or other similar officer of the body corporate;
(b)a person purporting to act as a director, manager, secretary or other similar officer; and
(c)if the affairs of the body corporate are managed by its members, a member.
(4) In this regulation, references to a “body corporate” include references to a partnership in Scotland, and in relation to such partnership, any reference to a director, manager, secretary or other similar officer of a body corporate is a reference to a partner.
30.—(1) Any document required or authorised by these Regulations to be served on a person may be so served—
(a)by delivering it to him or by leaving it at his proper address or by sending it by post to him at that address;
(b)if the person is a body corporate, by serving it in accordance with sub-paragraph (a) on the secretary or clerk of that body corporate; or
(c)if the person is a partnership, by serving it in accordance with sub-paragraph (a) on a partner or on a person having control or management of the partnership business.
(2) For the purposes of paragraph (1), and for the purposes of section 7 of the Interpretation Act 1978 M21 (which relates to the service of documents by post) in its application to that paragraph, the proper address of any person on whom a document is to be served in accordance with these Regulations shall be his last known address except that—
(a)in the case of service on a body corporate or its secretary or clerk, it shall be the address of the registered or principal office of the body corporate; and
(b)in the case of service on a partnership or a partner or a person having the control or management of a partnership business, it shall be the principal office of the partnership,
and for the purposes of this paragraph the principal office of a company registered outside the United Kingdom or of a partnership carrying on business outside the United Kingdom is its principal office within the United Kingdom.
31.—(1) Nothing in these Regulations shall be taken as requiring a person to produce any documents or records if he would be entitled to refuse to produce those documents or records in any proceedings in any court on the grounds that they are the subject of legal professional privilege or, in Scotland, that they contain a confidential communication made by or to an advocate or solicitor in that capacity, or as authorising a person to take possession of any documents or records which are in the possession of a person who would be so entitled.
(2) Nothing in these Regulations shall be construed as requiring a person to answer any question or give any information if to do so would incriminate that person or that person's spouse or civil partner.
(3) Section 14(1) of the Civil Evidence Act 1968 M22 (which relates to the privilege against self-incrimination) shall apply to the right conferred by paragraph (2) as it applies to the right described in that section; but this paragraph does not extend to Scotland.
32. In their application to Northern Ireland, these Regulations shall have effect subject to Schedule 6.
Barry Gardiner
Parliamentary Under Secretary of State for Competitiveness
Department of Trade and Industry
28th April 2006
Regulations 2(1) and 14(a)
1. The essential requirements are the relevant requirements relating to measuring systems contained in Annex I and Annex MI-005, set out in this Schedule.U.K.
2.—(1) In this Schedule—
“associated measuring instrument” means measuring equipment connected to the calculator for measuring certain quantities which are characteristic of the liquid fuel, with a view to make a correction and/or conversion;
“base conditions” means the specified conditions to which the measured quantity of liquid fuel at metering conditions is converted;
“calculator” means a part of a meter that receives the output signals from the measurement transducer(s) and possibly from associated measuring instruments and displays the measurement results;
“climatic environments” means the conditions in which measuring systems may be used;
“conversion device” means a part of the calculator which by taking account of the characteristics of the liquid fuel (e.g. temperature, density) measured using associated measuring instruments, or stored in a memory, automatically converts—
the volume of the liquid fuel measured at metering conditions into a volume at base conditions and/or into mass;
the mass of the liquid fuel measured at metering conditions into a volume at metering conditions and/or into a volume at base conditions,
and includes the relevant associated measuring instruments;
“critical change value” means the value at which the change in the measurement result is considered undesirable;
“direct indication” means the indication, either volume or mass, corresponding to the measure and that the meter is physically capable of measuring;
“direct sale” means a trading transaction if—
the measurement result serves as the basis for the price to pay;
at least one of the parties involved in the transaction related to measurement is a consumer or any other party requiring a similar level of protection; and
all the parties in the transaction accept the measurement result at that time and place;
“disturbance” means an influence quantity having a value within the limits specified in the appropriate requirement but outside the specified rated operating conditions of the instrument. An influence quantity is a disturbance if for that influence quantity the rated operating conditions are not specified;
“fuel dispenser” means a measuring system intended for the refuelling of motor vehicles, small boats and small aircraft;
“influence quantity” means a quantity that is not the measurand but that affects the result of measurement;
“interruptible” means the liquid fuel flow can be stopped easily and rapidly;
“measurand” means the particular quantity subject to measurement;
“Qmax” means the maximum flowrate;
“Qmin” means the minimum flowrate;
“rated operating conditions” means the values for the measurand and influence quantities making up the normal working conditions of an instrument;
“self-service arrangement” means an arrangement that allows the customer to use a measuring system for the purpose of obtaining liquid fuel for his own use; and
“self-service device” means a specific device that is part of a self-service arrangement and which allows one or more measuring systems to perform in this self-service arrangement.
(2) In this Schedule, volume may be read as mass and “L” may be read as kg.
3.—(1) Under rated operating conditions and in the absence of a disturbance, the error of measurement shall not exceed the maximum permissible error (MPE) value set out in paragraph 16.
(2) Unless stated otherwise, MPE is expressed as a bilateral value of the deviation from the true measurement value.
(3) Under rated operating conditions and in the presence of a disturbance, the performance requirement shall be as set out in paragraph 17.
(4) Where the measuring system is intended to be used in a specified permanent continuous electromagnetic field the permitted performance during the radiated electromagnetic field-amplitude modulated test shall be within MPE.
(5) The manufacturer shall specify the climatic, mechanical and electromagnetic environments in which the instrument is intended to be used, power supply and other influence quantities likely to affect its accuracy, taking account of the requirements in this Schedule.
(a)Climatic environments—
The manufacturer shall specify the upper temperature limit and the lower temperature limit from any of the values in Table 1, and indicate whether the measuring system is designed for condensing or non-condensing humidity as well as the intended location for the instrument, i.e. open or closed.
Temperature Limits | ||||
---|---|---|---|---|
Upper temperature limit | 30°C | 40°C | 55°C | 70°C |
Lower temperature limit | 5°C | –10°C | –25°C | –40°C |
(b)Mechanical environments—
(i)Mechanical environments are classified into classes M1 to M3 as follows—
M1: This class applies to instruments used in locations with vibration and shocks of low significance, e.g. for instruments fastened to light supporting structures subject to negligible vibrations and shocks transmitted from local blasting or pile-driving activities, slamming doors.
M2: This class applies to instruments used in locations with significant or high levels of vibration and shock, e.g. transmitted from machines and passing vehicles in the vicinity or adjacent to heavy machines, conveyor belts.
M3: This class applies to instruments used in locations where the level of vibration and shock is high and very high, e.g. for instruments mounted directly on machines, conveyor belts.
(ii)The following influence quantities shall be considered in relation to mechanical environments—
(aa)vibration;
(bb)mechanical shock
(c)Electromagnetic environments—
(i)Electromagnetic environments are classified into classes E1, E2 or E3 as follows—
E1: This class applies to instruments used in locations with electromagnetic disturbances corresponding to those likely to be found in residential, commercial and light industrial buildings.
E2: This class applies to instruments used in locations with electromagnetic disturbances corresponding to those likely to be found in other industrial buildings.
E3: This class applies to instruments supplied by the battery of a vehicle. Such instruments shall comply with the requirements of E2 and the following additional requirements—
(aa)voltage reductions caused by energising the starter-motor circuits of internal combustion engines; and
(bb)load dump transients occurring in the event of a discharged battery being disconnected while the engine is running.
(ii)The following influence quantities shall be considered in relation with electromagnetic environments—
(aa)voltage interruptions;
(bb)short voltage reductions;
(cc)voltage transients on supply lines and/or signal lines;
(dd)electrostatic discharges;
(ee)radio frequency electromagnetic fields;
(ff)conducted radio frequency electromagnetic fields on supply lines and/or signal lines;
(gg)surges on supply lines and/or signal lines.
(6) Other influence quantities to be considered, where appropriate, are—
(a)voltage variation;
(b)mains frequency variation;
(c)power frequency magnetic fields;
(d)any other quantity likely to influence in a significant way the accuracy of the instrument.
(7) When carrying out the tests as envisaged in these Regulations, the following paragraphs apply—
(a)Basic rules for testing and the determination of errors—
(i)Essential requirements specified in sub-paragraphs (1) to (4) shall be verified for each relevant influence quantity. These essential requirements apply when each influence quantity is applied and its effect evaluated separately, all other influence quantities being kept relatively constant at their reference value.
(ii)Metrological tests shall be carried out during or after the application of the influence quantity, whichever condition corresponds to the normal operational status of the instrument when that influence quantity is likely to occur.
(b)Ambient humidity—
(i)According to the climatic operating environment in which the instrument is intended to be used either the damp heat-steady state (non-condensing) or damp heat cyclic (condensing) test may be appropriate.
(ii)The damp heat cyclic test is appropriate where condensation is important or when penetration of vapour will be accelerated by the effect of breathing. In conditions where non-condensing humidity is a factor the damp-heat steady state is appropriate.
4. The application of the same measurand in a different location or by a different user, all other conditions being the same, shall result in the close agreement of successive measurements. The difference between the measurement results shall be small when compared with the MPE.
5. The application of the same measurand under the same conditions of measurement shall result in the close agreement of successive measurements. The difference between the measurement results shall be small when compared with the MPE.
6. A measuring system shall be sufficiently sensitive and the discrimination threshold shall be sufficiently low for the intended measurement task.
7.—(1) A measuring system shall be designed to maintain an adequate stability of its metrological characteristics over a period of time estimated by the manufacturer, provided that it is properly installed, maintained and used according to the manufacturer's instruction when in the environmental conditions for which it is intended.
(2) After an appropriate test, taking into account the period of time estimated by the manufacturer, has been performed, the following criterion shall be satisfied; the variation of the measurement result after the durability test, when compared with the initial measurement result, shall not exceed the value for meters specified in line B of Table 3 set out in paragraph 16.
8. A measuring system shall be designed to reduce as far as possible the effect of a defect that would lead to an inaccurate measurement result, unless the presence of such a defect is obvious.
9.—(1) A measuring system shall have no feature likely to facilitate fraudulent use, whereas possibilities for unintentional misuse shall be minimal.
(2) A measuring system shall be suitable for its intended use taking account of the practical working conditions and shall not require unreasonable demands of the user in order to obtain a correct measurement result.
(3) Where a measuring system is designed for the measurement of values of the measurand that are constant over time, the instrument shall be insensitive to small fluctuations of the value of the measurand, or shall take appropriate action.
(4) A measuring system shall be robust and its materials of construction shall be suitable for the conditions in which it is intended to be used.
(5) A measuring system shall be designed so as to allow the control of the measuring tasks after the instrument has been placed on the market and put into use. If necessary, special equipment or software for this control shall be part of the instrument. The test procedure shall be described in the operation manual.
(6) When an instrument has associated software which provides other functions besides the measuring function, the software that is critical for the metrological characteristics shall be identifiable and shall not be inadmissibly influenced by the associated software.
(7) For any measured quantity relating to the same measurement, the indications provided by various devices shall not deviate one from another by more than one scale interval where devices have the same scale interval. In the case where the devices have different scale intervals, the deviation shall not be more than that of the greatest scale interval.
(8) In the case of a self-service arrangement the scale intervals of the main indicating device on the measuring system and the scale intervals of the self-service device shall be the same and results of measurement shall not deviate one from another.
(9) It shall not be possible to divert the measured quantity in normal conditions of use unless it is readily apparent.
(10) Any percentage of air or gas not easily detectable in the liquid fuel shall not lead to a variation of error greater than—
(a)0.5 % for liquid fuel of a viscosity not exceeding 1 mPa.s; or
(b)1 % for liquid fuel of a viscosity exceeding 1 mPa.s.,
but the allowed variation shall never be smaller than 1% of the minimum measured quantity and this value applies in the case of air or gas pockets.
(11) Instruments for direct sales—
(a)A measuring system for direct sales shall be provided with means for resetting the display to zero.
(b)It shall not be possible to divert the measured quantity.
(c)The display of the quantity on which the transaction is based shall be permanent until all parties in the transaction have accepted the measurement result.
(d)Measuring systems for direct sales shall be interruptible.
(e)Any percentage of air or gas in the liquid fuel shall not lead to a variation of error greater than the values specified in sub-paragraph (10).
(12) Fuel dispensers—
(a)Displays on fuel dispensers shall not be capable of being reset to zero during a measurement.
(b)The start of a new measurement shall be inhibited until the display has been reset to zero.
(c)Where a measuring system is fitted with a price display, the difference between the indicated price and the price calculated from the unit price and the indicated quantity shall not exceed the price corresponding to Emin but this difference need not be less than the smallest monetary value.
10.—(1) The metrological characteristics of a measuring system shall not be influenced in any inadmissible way by the connection to it of another device, by any feature of the connected device itself or by any remote device that communicates with the instrument.
(2) A hardware component that is critical for metrological characteristics shall be designed so that it can be secured. Security measures foreseen shall provide for evidence of an intervention.
(3) Software that is critical for metrological characteristics shall be identified as such and shall be secured.
(4) Software identification shall be easily provided by the instrument.
(5) Evidence of a software intervention shall be available for a reasonable period of time.
(6) Measurement data, software that is critical for measurement characteristics and metrologically important parameters stored or transmitted shall be adequately protected against accidental or intentional corruption.
11.—(1) A measuring system shall bear the following inscriptions—
(a)manufacturer's mark or name;
(b)information in respect of its accuracy,
plus, when applicable—
(c)information in respect of the conditions of use;
(d)measuring capacity;
(e)measuring range;
(f)identity marking;
(g)number of the EC-type examination certificate or the EC design examination certificate;
(h)information whether or not additional devices providing metrological results comply with these Regulations.
(2) An instrument of dimensions too small or of too sensitive a composition to allow it to bear the relevant information shall have its packaging, if any, and the accompanying documents required by the provisions of these Regulations suitably marked.
(3) The instrument shall be accompanied by information on its operation, unless the simplicity of the instrument makes this unnecessary. Information shall be easily understandable and shall include where relevant—
(a)rated operating conditions;
(b)mechanical and electromagnetic environment classes;
(c)the upper and lower temperature limit, whether condensation is possible or not, open or closed location;
(d)instructions for installation, maintenance, repairs, permissible adjustments;
(e)instructions for correct operation and any special conditions of use;
(f)conditions for compatibility with interfaces or measuring instruments.
(4) Groups of identical measuring systems used in the same location do not necessarily require individual instruction manuals.
(5) The scale interval for a measured value shall be in the form 1 x 10n, 2 x 10n or 5 x 10n, where n is any integer or zero. The unit of measurement or its symbol shall be shown close to the numerical value.
(6) The units of measurement used and their symbols shall be in accordance with the provisions of Community legislation on units of measurement and their symbols.
(7) All marks and inscriptions required under any requirement shall be clear, non-erasable, unambiguous and non-transferable.
12.—(1) Indication of the result shall be by means of a display or hard copy.
(2) The indication of any result shall be clear and unambiguous and accompanied by such marks and inscriptions necessary to inform the user of the significance of the result. Easy reading of the presented result shall be permitted under normal conditions of use. Additional indications may be shown provided they cannot be confused with the metrologically controlled indications.
(3) In the case of hard copy the print or record shall also be easily legible and non-erasable.
(4) A measuring system for direct sales trading transactions shall be designed to present the measurement result to both parties in the transaction when installed as intended. When critical in case of direct sales, any ticket provided to the consumer by an ancillary device not complying with the appropriate requirements of these Regulations shall bear an appropriate restrictive information.
(5) The direct indication may be converted into another quantity using a conversion device.
13.—(1) A measuring system shall record by a durable means the measurement result accompanied by information to identify the particular transaction, when—
(a)the measurement is non-repeatable; and
(b)the measuring system is normally intended for use in the absence of one of the trading parties.
(2) Additionally, a durable proof of the measurement result and the information to identify the transaction shall be available on request at the time the measurement is concluded.
14. A measuring system shall be designed so as to allow ready evaluation of its conformity with the appropriate requirements of these Regulations.
15. The manufacturer shall specify the rated operating conditions for the instrument, in particular—
(a)the flowrate range is subject to the following conditions—
(i)the flowrate range of a measuring system shall be within the flowrate range of each of its elements, in particular the meter;
(ii)the minimum ratio of Qmax : Qmin set out in Table 2;
(b)the properties of the liquid fuel to be measured by the instrument by specifying the name or type of the liquid fuel or its relevant characteristics, for example—
(i)temperature range;
(ii)pressure range;
(iii)density range;
(iv)viscosity range;
(c)the nominal value of the AC voltage supply and/or limits of the DC voltage supply;
(d)the base conditions for converted values but this paragraph is without prejudice to the member States' obligations to require use of a temperature of either 15ºC in accordance with Article 3(1) of Council Directive 92/81/EEC of 19 October 1992 on the harmonisation of the structures of excise duties on mineral oils M23 or, for heavy fuel oils and methane, another temperature pursuant to Article 3(2) of that Directive.
Specific measuring system | Characteristic of liquid | Minimum ratio of Qmax : Qmin |
---|---|---|
Fuel dispensers | Liquid fuel other than liquefied gases and cryogenic liquids | 10:1 |
Liquefied gases | 5:1 | |
Cryogenic liquids | 5:1 | |
All other measuring systems | Lubricants | 4:1 |
16.—(1) For quantities equal to or greater than 2 litres the MPE on indications is set out in Table 3.
Accuracy Class | |||||
---|---|---|---|---|---|
0.3 | 0.5 | 1.0 | 1.5 | 2.5 | |
Measuring systems (A) | 0.3% | 0.5% | 1.0% | 1.5% | 2.5% |
Meter (B) | 0.2% | 0.3% | 0.6% | 1.0% | 1.5% |
(2) For quantities less than 2 litres the MPE on indications is set out in Table 4.
Measured volume V | MPE |
---|---|
V< 0.1 L | 4 x value in Table 3, applied to 0.1 L |
0.1 L ≤ V < 0.2 L | 4 x value in Table 3 |
0.2 L ≤ V< 0.4 L | 2 x value in Table 3, applied to 0.4 L |
0.4 L ≤ V< 1 L | 2 x value in Table 3 |
1 L ≤V < 2 L | Value in Table 3, applied to 2 L |
(3) No matter what the measured quantity may be, the magnitude of the MPE is given by the greater of the following two values—
(a)the absolute value of the MPE given in Table 3 or Table 4;
(b)the absolute value of the MPE for the minimum measured quantity (Emin).
(4) For minimum measured quantities greater than or equal to 2 litres the following conditions apply—
(a)Condition 1 - Emin shall fulfil the condition: Emin ≥ 2R, where R is the smallest scale interval of the indication device;
(b)Condition 2 - Emin is given by the formula: Emin = (2MMQ) x (A/100) where—
(i)MMQ is the minimum measured quantity;
(ii)A is the numerical value specified in line A of Table 3.
(5) For minimum measured quantities of less than 2 litres the condition set out in sub-paragraph 4(a) applies and E min is twice the value specified in Table 4, and related to line A of Table 3.
(6) Converted indications—
In the case of a converted indication the MPEs are as in line A of Table 3.
(7) Conversion devices—
MPEs on converted indications due to a conversion device are equal to ± (A-B), A and B being the values specified in Table 3.
(8) Parts of conversion devices that can be tested separately—
(a)Calculator—
MPEs on quantities of liquid indications applicable to calculation, positive or negative, are equal to one-tenth of the MPEs as defined in line A of Table 3.
(b)Associated measuring instruments—
Associated measuring instruments shall have an accuracy at least as good as the values in Table 5 and these values apply to the indication of the characteristic quantities of the liquid fuel displayed by the conversion device.
(c)Accuracy for calculating function—
The MPE for the calculation of each characteristic quantity of the liquid fuel, positive or negative, is equal to two fifths of the value fixed in paragraph (b).
(9) The requirement in sub-paragraph (8)(a) applies to any calculation, not only conversion.
MPE on Measurements | Accuracy classes of the measuring system | ||||
---|---|---|---|---|---|
0.3 | 0.5 | 1.0 | 1.5 | 2.5 | |
Temperature | ± 0.3ºC | ± 0.5ºC | ± 1.0ºC | ||
Pressure | Less than 1 MPa: ± 50 kPa From 1 to 4 MPa: ± 5% Over 4 MPa: ± 200 kPa | ||||
Density | ± 1 kg/m3 | ± 2 kg/m3 | ± 5 kg/m3 |
17.—(1) The effect of an electromagnetic disturbance on a measuring system shall be one of the following—
(a)the change in the measurement result is not greater than the critical change value as defined in sub-paragraph (2);
(b)the indication of the measurement result shows a momentary variation that cannot be interpreted, memorised or transmitted as a measuring result. Furthermore, in the case of an interruptible system, this can also mean the impossibility to perform any measurement; or
(c)the change in the measurement result is greater than the critical change value, in which case the measuring system shall permit the retrieval of the measuring result just before the critical change value occurred and cut off the flow.
(2) The critical change value is the greater of MPE/5 for a particular measured quantity or Emin.
18. A measuring system shall either be provided with an emergency power supply device that will safeguard all measuring functions during the failure of the main power supply device or be equipped with means to save and display the data present in order to permit the conclusion of the transaction in progress and with means to stop the flow at the moment of the failure of the main power supply device.
19. Table 6 sets out the accuracy classes applicable to measuring systems but where the manufacturer specifies an accuracy class of a higher level of precision, the instrument shall fall within that accuracy class specified by the manufacturer.
Accuracy Class | Types of Measuring System |
---|---|
0.3 | Instruments in class 0.5, 1.0, 1.5 or 2.5, where specified by the manufacturer |
0.5 | All instruments if not differently stated elsewhere in this Table including –fuel dispensers (not for liquefied gases), –measuring systems for refuelling aircraft |
1.0 | Instruments for liquefied gases under pressure measured at a temperature equal to or above –10 °C Instruments in class 0.3 or 0.5 but used for liquid fuel –whose temperature is less than –10 °C or greater than 50 ºC –whose dynamic viscosity is higher than 1000 mPa.s –whose maximum volumetric flowrate is not higher than 20 L/h |
1.5 | Instruments for liquefied gases under pressure measured at a temperature below –10 °C (other than cryogenic liquids) |
2.5 | Instruments for cryogenic liquids (temperature below –153 °C) |
20. The metered quantity shall be displayed in millilitre, cubic centimetres, litres, cubic metres, grams, kilograms or tonnes.
Regulations 2(1) and 8
1. The body, its director and staff involved in conformity assessment tasks shall not be the designer, manufacturer, supplier, installer or user of the measuring system that they inspect, nor the authorised representative of any of them. In addition, they may not be directly involved in the design, manufacture, marketing or maintenance of the instrument, nor represent the parties engaged in these activities. The preceding criterion does not, however, preclude in any way the possibility of exchanges of technical information between the manufacturer and the body for the purposes of conformity assessment.U.K.
2. The body, its director and staff involved in conformity assessment tasks shall be free from all pressures and inducements, in particular financial inducements, that might influence their judgement or the results of their conformity assessment, especially from persons or groups of persons with an interest in the results of the assessments.U.K.
3. The conformity assessment shall be carried out with the highest degree of professional integrity and requisite competence in the field of metrology. Should the body sub-contract specific tasks, it shall first ensure that the sub-contractor meets the requirements of these Regulations, and in particular of this Schedule. The body shall keep the relevant documents assessing the sub-contractor's qualifications and the work carried out by him under these Regulations at the disposal of the Secretary of State.U.K.
4. The body shall be capable of carrying out all the conformity assessment tasks for which it has been designated, whether those tasks are carried out by the body itself or on its behalf and under its responsibility. It shall have at its disposal the necessary staff and shall have access to the necessary facilities for carrying out in a proper manner the technical and administrative tasks entailed in conformity assessment.U.K.
5. The body's staff shall have—U.K.
(a)sound technical and vocational training, covering all conformity assessment tasks for which the body was designated;
(b)satisfactory knowledge of the rules governing the tasks which it carries out, and adequate experience of such tasks; and
(c)the requisite ability to draw up the certificates, records and reports demonstrating that the tasks have been carried out.
6. The impartiality of the body, its director and staff shall be guaranteed. The remuneration of the body shall not depend on the results of the tasks it carries out. The remuneration of the body's director and staff shall not depend on the number of tasks carried out or on the results of such tasks.U.K.
7. The body shall satisfy the Secretary of State that it has adequate civil liability insurance.U.K.
8. The body's director and staff shall be bound to observe professional secrecy with regard to all information obtained in the performance of their duties pursuant to these Regulations, except vis-à-vis the Secretary of State.U.K.
9.—(1) Subject to paragraph 10, a notified body shall assess an application made by a manufacturer for the issue of—
(a)a certificate of conformity;
(b)a design or type examination certificate; or
(c)a notification of approval of the manufacturer's quality system,
in accordance with the Annex applicable to the relevant conformity assessment procedure in respect of a measuring system.
(2) In determining such an application, the notified body—
(a)shall have regard to the actual or usual environment of the measuring system; and
(b)may have regard to any other standard or other technical criteria appearing to it to be relevant.
(3) Where, in the opinion of the notified body, the measuring system to which an application relates is compliant with the essential requirements, it shall issue a certificate or notification in accordance with paragraph 12.
(4) Where, in the opinion of the notified body, the measuring system to which an application relates is not compliant with the essential requirements, it shall issue a notice to the applicant in accordance with paragraph 15.
(5) Where a certificate or notification under sub-paragraph (3) is issued by a United Kingdom notified body, it shall send a copy to the Secretary of State.
10.—(1) A notified body shall not accept an application for a certificate or notification in respect of a measuring system unless the application—
(a)is in writing, in English or another language acceptable to that notified body;
(b)is accompanied by all relevant documentation, in which all writing is in English or another language acceptable to that notified body; and
(c)includes particulars of which applicable standards the manufacturer has applied or proposes to apply in respect of the instrument.
(2) A notified body shall not be required to determine an application for a certificate or notification where the manufacturer has not—
(a)granted the notified body access to an instrument to which the application relates or the production facilities for the instrument (including, where applicable, the production facilities envisaged in relation to a representative instrument) to the extent that the notified body reasonably requests; and
(b)made available to the notified body such information as it may reasonably require to determine the application.
(3) A notified body shall not be required to carry out the functions referred to in regulation 7(4)(d) if—
(a)the person making the application has not submitted with the application the amount of the fee which the notified body requires to be submitted with the application pursuant to regulation 11; or
(b)the notified body reasonably believes that, having regard to the number of applications made to it pursuant to its designation which are outstanding, it will be unable to commence the required work within three months of receiving the application.
11.—(1) A notified body may, in exercising its functions—
(a)arrange for some other person to carry out any test, assessment or inspection on its behalf; or
(b)require the applicant to satisfy another person with respect to any matter at the applicant's expense.
(2) But nothing in sub-paragraph (1) authorises a notified body to rely on the opinion of another person with regard to whether a measuring system is compliant with any of the essential requirements.
(3) Nothing in these Regulations shall preclude a person referred to in sub-paragraph (1)(a) or (1)(b) from charging any fee in respect of any work undertaken by him in pursuance of those sub-paragraphs.
12. The certificate or notification issued by the notified body shall be in writing and, in addition to the requirements provided for in the relevant conformity assessment procedure, shall—
(a)be in English;
(b)give the name and address—
(i)of the applicant;
(ii)where the applicant is not the manufacturer, of the manufacturer;
(c)be signed by or on behalf of the notified body and give the identification number of the notified body;
(d)bear—
(i)the date of issue; and
(ii)the number of the certificate or notification;
(e)give particulars of the relevant measuring system (where applicable, in relation to each variant) to which it relates sufficient to identify it, and shall state whether the instrument to which it relates is a single item or a representative, or if it covers a number of variants of that instrument; and
(f)certify that the instrument to which it relates is compliant with the essential requirements.
13.—(1) A certificate or notification may be unconditional or may be subject to such conditions as the notified body considers appropriate.
(2) Such conditions may include—
(a)a limitation on the environment for which the measuring system is stated to be suitable; or
(b)a requirement that the instrument is only to be installed at a specific site.
(3) The conditions imposed pursuant to sub-paragraph (1) may be varied in accordance with paragraph 15 by the notified body which issued the certificate or notification and such a variation may include the imposition of new conditions or the removal of conditions.
14. The notified body which issued the certificate or notification shall withdraw that certificate or notification in accordance with paragraph 15, if it appears that the measuring system to which it relates is not compliant with the essential requirements.
15.—(1) Where a notified body is minded to—
(a)refuse to issue a certificate or notification;
(b)vary a certificate or notification (other than at the request of the person to whom it was given); or
(c)withdraw a certificate or notification,
it shall give to the applicant, or the person to whom the certificate or notification was given, a notice in writing—
(i)giving reasons for the refusal, variation or withdrawal;
(ii)specifying the date on which the refusal, variation or withdrawal is to take effect; and
(iii)giving the applicant or person the opportunity to make representations within 21 days from the date of the notice and stating that the notified body shall consider any representations made to it within that period by that applicant or person.
(2) Where a notified body, having considered representations made to it under sub-paragraph (1), remains of the opinion that—
(a)an application for a certificate or notification should be refused; or
(b)a certificate or notification should be varied or withdrawn,
it shall inform the applicant, or the person to whom the certificate or notification was given, of that decision in writing and give that applicant or person information about the judicial remedies available to him.
(3) Where a notice is given under sub-paragraph (1) by a United Kingdom notified body, it shall send a copy to the Secretary of State.
Regulation 6(2)
1. The technical documentation shall render the design, manufacture and operation of the instrument intelligible and shall permit an assessment of its conformity with the appropriate requirements of these Regulations.U.K.
2. The technical documentation shall be sufficiently detailed to ensure—U.K.
(a)the definition of the metrological characteristics;
(b)the reproducibility of the metrological performances of produced instruments when properly adjusted using appropriate intended means; and
(c)the integrity of the instrument.
3. The technical documentation shall include insofar as relevant for assessment and identification of the type and/or instrument—U.K.
(a)a general description of the instrument;
(b)conceptual design and manufacturing drawings and plans of components and circuits;
(c)manufacturing procedures to ensure consistent production;
(d)if applicable, a description of the electronic devices with drawings, diagrams, flow diagrams of the logic and general software information explaining their characteristics and operation;
(e)descriptions and explanations necessary for the understanding of sub-paragraphs (b), (c) and (d), including the operation of the instrument;
(f)a list of the relevant national standards and/or relevant normative documents, applied in full or in part;
(g)descriptions of the solutions adopted to meet the essential requirements where the relevant national standards and/or relevant normative documents have not been applied;
(h)results of design calculations and examinations;
(i)the appropriate test results, where necessary, to demonstrate that the type and/or instrument is compliant with the requirements of these Regulations under declared rated operating conditions and under specified environmental disturbances and with the durability specifications; and
(j)the EC-type examination certificates or EC design examination certificates in respect of instruments containing parts identical to those in the design.
4. The manufacturer shall specify where seals and markings have been applied.U.K.
5. The manufacturer shall indicate the conditions for compatibility with interfaces where relevant.U.K.
Regulation 12(3)
1. The CE marking consists of the symbol “CE” according to the design laid down in paragraph I.B(d) of the Annex to Decision 93/465/EEC M24. The CE marking shall be at least 5 mm high.U.K.
2. The M marking consists of the capital letter “M” and the last two digits of the year of its affixing, surrounded by a rectangle. The height of the rectangle shall be equal to the height of the CE marking. The M marking shall immediately follow the CE marking.U.K.
3. The identification number of the notified body concerned shall follow the CE marking and the M marking.U.K.
4. When a measuring system consists of a set of devices operating together, the markings shall be affixed on the instrument's main device.U.K.
5. The CE marking and the M marking shall be indelible. The identification number of the notified body concerned shall be indelible or self-destructive upon removal. All markings shall be clearly visible or easily accessible.U.K.
Regulation 15
1.—(1) In this Schedule—U.K.
(a)“L” means litre;
(b)“mL” means millilitre;
(c)“kg” means kilogram;
(d)“g” means gram; and
(e)“MPE” means maximum permissible error.
(2) For measuring systems which measure in mass—
(a)“L” shall be read as “kg”; and
(b)“mL” shall be read as “g”.
2. The MPEs for use for trade for quantities above the minimum measured quantity of the measuring system are set out in Table 1.U.K.
Accuracy class of the measuring system | |||||
---|---|---|---|---|---|
0.3 | 0.5 | 1.0 | 1.5 | 2.5 | |
Column 1 | Column 2 | Column 3 | Column 4 | Column 5 | Column 6 |
Quantity | MPE | MPE | MPE | MPE | MPE |
Less than 0.1L | + 4.8ml - 2.4mL | + 8mL - 4mL | + 16mL - 8mL | + 24mL - 12mL | + 40mL - 20mL |
From 0.1L to < 0.2L | + 4.8% - 2.4% | + 8% - 4% | + 16% - 8% | + 24% - 12% | + 40% - 20% |
From 0.2L to < 0.4L | + 4.8mL - 2.4mL | + 8mL - 4mL | + 16mL - 8mL | + 24mL - 12ml | + 40mL - 20mL |
From 0.4L to < 1L | + 1.2% - 0.6% | + 2% - 1% | + 4% - 2% | + 6% - 3% | + 10% - 5% |
From 1L to < 2L | + 12mL - 6mL | + 20mL - 10mL | + 40mL - 20mL | + 60mL - 30mL | + 100mL - 50mL |
2L or more | + 0.6% - 0.3% | + 1% - 0.5% | + 2% - 1% | + 3% - 1.5% | + 5% - 2.5% |
3. The MPEs for use for trade for quantities equal to the minimum measured quantity of the measuring system are set out in Table 2.U.K.
Accuracy class of the measuring system | |||||
---|---|---|---|---|---|
0.3 | 0.5 | 1.0 | 1.5 | 2.5 | |
Column 1 | Column 2 | Column 3 | Column 4 | Column 5 | Column 6 |
Quantity | MPE | MPE | MPE | MPE | MPE |
Less than 0.1L | + 4.8ml - 2.4mL | + 8mL - 4mL | + 16mL - 8mL | + 24mL - 12mL | + 40mL - 20mL |
From 0.1L to < 0.2L | + 4.8% - 2.4% | + 8% - 4% | + 16% - 8% | + 24% - 12% | + 40% - 20% |
From 0.2L to < 0.4L | + 9.6mL - 4.8mL | + 16mL - 8mL | + 32mL -16mL | + 48mL - 24mL | + 80mL - 40mL |
From 0.4L to < 1L | + 2.4% - 1.2% | + 4% - 2% | + 8% - 4% | + 12% - 6% | + 20% - 10% |
From 1L to < 2L | + 24mL - 12mL | + 40mL - 20mL | + 80mL - 40mL | + 120mL - 60mL | + 200mL - 100mL |
2L or more | + 1.2% - 0.6% | + 2% - 1% | + 4% - 2% | + 6% - 3% | + 10% - 5% |
Regulation 32
1. In regulation 2(2), the reference to the Weights and Measures Act 1985 M25 shall be construed as a reference to the Weights and Measures (Northern Ireland) Order 1981 M26.U.K.
2. Part III does not apply to Northern Ireland.U.K.
3. In regulation 17—U.K.
(a)for paragraph (1), substitute the following paragraph—
“(1) The Department of Enterprise, Trade and Investment shall enforce these Regulations in Northern Ireland.”; and
(b)for paragraph (3), substitute the following paragraph—
“(3) No proceedings for an offence under these Regulations shall be instituted in Northern Ireland except by or on behalf of the Department of Enterprise, Trade and Investment or the Director of Public Prosecutions for Northern Ireland.”.
4. In regulation 25—U.K.
(a)the reference in paragraph (3) to written information on oath shall be construed as a reference to a complaint on oath; and
(b)for paragraph (9), substitute the following paragraph—
“(9) In this regulation, “credentials” in relation to an enforcement officer, means an authenticated document showing that he is authorised to act to exercise the powers conferred on him by this regulation.”.
5. In regulation 31(3), the reference to section 14(1) of the Civil Evidence Act 1968 shall be construed as a reference to section 10(1) of the Civil Evidence Act (Northern Ireland) 1971 M27.U.K.
(This note is not part of the Regulations)
These Regulations implement Directive 2004/22/EC of the European Parliament and of the Council on measuring instruments (OJ No. L135, 30.4.04, p.1) (“the Directive”) in relation to measuring systems.
Part I provides that these Regulations apply, with certain exceptions, to measuring systems which are placed on the market or put into use on or after the 30th October 2006, for use for trade in the making of a continuous and dynamic measurement of liquid fuel in a quantity equal to or less than 100 litres or 100 kilograms.
Part II deals with the requirements for placing on the market and putting into use. These are that measuring systems are compliant with the essential requirements, that manufacturers have demonstrated their compliance with the essential requirements and that measuring systems have the CE marking, the M marking, and identification number of the relevant notified body affixed to them (regulation 4(1)). It is an offence under regulation 4(2) to place on the market or put into use a measuring system without complying with the requirements of regulation 4(1). The essential requirements are set out in Schedule 1. Compliance with the essential requirements can be demonstrated in accordance with the provisions in regulation 5. Regulation 6 sets out the different conformity assessment procedures available to a manufacturer to demonstrate compliance. The technical documentation required is set out in Schedule 3.
Regulations 7 to 11 and Schedule 2 contain provisions relating to the eligibility and designation of persons as notified bodies and with the administrative procedures relating to their appointment, functions and fees. Requirements relating to the marking of measuring systems are set out in regulation 12 and Schedule 4. Regulation 13 provides for a presumption of conformity of a measuring system with other applicable directives conferred by the CE marking.
Part III of these Regulations deals with requirements relating to the use for trade of measuring systems (regulations 14 to 16 and Schedule 5) pursuant to section 15(1) of the Weights and Measures Act 1985. Failure to comply with these requirements is an offence under section 15(3) of that Act.
Part IV deals with enforcement of these Regulations. Regulation 17 provides that the Regulations shall be enforced by every local weights and measures authority within its area; the Secretary of State may act as an enforcement authority in relation to Part II and for that purpose may appoint any person to act on his behalf. Regulation 18 (compliance notice procedure) and regulation 19 (immediate enforcement action) confer powers on the enforcement authorities to take action in respect of non-compliant measuring systems. Regulation 20 permits a review by the Secretary of State of notices issued by other enforcement authorities under regulations 18 and 19. Regulation 21 provides for disqualification of measuring systems and it is an offence to use a measuring system which has been disqualified unless it has been re-qualified in accordance with regulation 22. Regulation 23 provides for the testing of measuring systems by an inspector otherwise than for the purposes of re-qualification.
Regulation 24 details the offences relating to the unauthorised application of authorised marks. Regulation 25 provides powers of entry and inspection for enforcement officers. Regulation 26 provides for offences relating to the obstruction of an enforcement officer. A person guilty of an offence under Part II or Part IV is liable on summary conviction to a fine not exceeding level 5 on the standard scale (which is currently £5,000) (regulation 27). A defence of due diligence in relation to any offence under these Regulations is provided for in regulation 28 and the liability of persons other than the principal offender is set out in regulation 29.
Part V (regulations 30 to 32) deals with miscellaneous matters including the application of the Regulations to Northern Ireland to the extent set out in Schedule 5 (regulation 32).
These Regulations have been notified to the European Commission and the other member States in accordance with Directive 98/34/EC of the European Parliament and of the Council (OJ No. L204, 21.7.98, p.37), as amended by Directive 98/48/EC of the European Parliament and of the Council (OJ No. L217, 5.8.98, p.18).
A Regulatory Impact Assessment (RIA) in respect of these Regulations is available and a copy can be obtained from the National Weights and Measures Laboratory (NWML), Stanton Avenue, Teddington, Middlesex TW11 OJZ or from its website at www.nwml.gov.uk. As these Regulations transpose the Directive, a transposition note (TN) setting out how the Government has transposed the Directive into the United Kingdom has been prepared. Copies of the RIA and TN are available from NWML as above. Copies of these documents have been placed in the libraries of both Houses of Parliament.
Yr Offeryn Cyfan you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.
Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.
Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Mae Memoranda Esboniadol yn nodi datganiad byr o ddiben Offeryn Statudol ac yn rhoi gwybodaeth am ei amcan polisi a goblygiadau polisi. Maent yn ceisio gwneud yr Offeryn Statudol yn hygyrch i ddarllenwyr nad oes ganddynt gymhwyster cyfreithiol, ac maent yn cyd-fynd ag unrhyw Offeryn Statudol neu Offeryn Statudol Drafft a gyflwynwyd ger bron y Senedd o Fehefin 2004 ymlaen.
Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:
liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys
The data on this page is available in the alternative data formats listed: