Chwilio Deddfwriaeth

The Measuring Instruments (Non-Prescribed Instruments) Regulations 2006 (revoked)

Changes over time for: Paragraph 46

 Help about opening options

Version Superseded: 28/12/2016

Alternative versions:

Status:

Point in time view as at 30/10/2006. This version of this provision has been superseded. Help about Status

Close

Status

You are viewing this legislation item as it stood at a particular point in time. A later version of this or provision, including subsequent changes and effects, supersedes this version.

Note the term provision is used to describe a definable element in a piece of legislation that has legislative effect – such as a Part, Chapter or section.

Changes to legislation:

There are currently no known outstanding effects for the The Measuring Instruments (Non-Prescribed Instruments) Regulations 2006 (revoked), Paragraph 46. Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

Automatic CatchweighersU.K.
This adran has no associated Memorandwm Esboniadol

46.—(1) In addition to the requirements set out in paragraphs 44 and 45, the following specific requirements shall apply in relation to automatic catchweighers.

(2) Definitions—

weight labeller” means an automatic catchweigher that labels individual articles with the weight value;

weight/price labeller” means an automatic catchweigher that labels individual articles with the weight value, and price information.

(3) Accuracy Classes

(a)Instruments are divided into primary categories designated by X or Y as specified by the manufacturer.

(b)These categories are divided into four accuracy classes—

(i)XI, XII, XIII and XIV and

(ii)Y(I), Y(II), Y(a) and Y(b)

which shall be specified by the manufacturer.

(c)Category X applies to instruments used to check pre-packages made up in accordance with the requirements of Council Directive 75/106/EEC of 19 December 1974 on the approximation of the laws of the member States relating to the making-up by volume of certain pre-packaged liquids M1 and of Council Directive 76/211/EEC of 20th January 1976 on the approximation of the laws of the member States relating to the making-up by weight or by volume of certain pre-packaged products M2 applicable to pre-packages.

(d)The accuracy classes are supplemented by a factor (x) that qualifies the maximum permissible standard deviation as specified in sub-paragraph (3)(b).

(e)The manufacturer shall specify the factor (x), where (x) shall be ≤ 2 and in the form 1 × 10k, 2 × 10k or 5 × 10k, where k is a negative whole number or zero.

(f)Category Y applies to all other automatic catchweighers.

(4) MPE

(a)Mean error Category X and MPE Category Y Instruments

Table 7
Net Load (m) in verification scale intervals (c)Maximum permissible mean errorMaximum permissible error
XIY(1)XIIY(II)XIIIY(a)XIVY(b)XY
0 < m ≤ 50 0000 < m ≤ 5 0000 < m ≤ 5000 < m ≤ 50± 0.5 e±1 e
50 000 < m ≤ 200 0005 000 < m ≤ 20 000500 < m ≤ 2 00050 < m ≤ 200± 1.0 e±1.5 e
200 000 < m20 000 < m ≤ 100 0002 000 < m ≤ 10 000200 < m ≤ 1 000± 1.5 e± 2 e

(b)Standard deviation—

Maximum permissible value for the standard deviation of a class X (x) instrument is the result of the multiplication of the factor (x) by the value in Table 8 below.

Table 8
Net Load (m)Maximum permissible standard deviation for class X(1)
m ≤ 50g0.48%
50 g < m ≤ 100 g0.24 g
100 g < m ≤ 200 g0.24 %
200 g < m ≤ 300 g0.48 g
300 g < m ≤ 500 g0.16 %
500g < m ≤ 1 000 g0.8 g
1 000 g < m ≤ 10 000 g0.08 %
10 000 g < m ≤ 15 000 g8 g
15 000 g < m0.053 %

For class XI and XII (x) shall be less than 1.

For class XIII (x) shall be not greater than 1.

For class XIV (x) shall be greater than 1.

(c)Verification scale interval – single interval instruments

Table 9
Accuracy classesVerification scale intervalNumber of verification scale intervals n= Max/e
  MinimumMaximum
XIY(I)0.001 g ≤ e50 000
XIIY(II)

0.001 g ≤ e ≤0.05 g

100100 000
0.1 g ≤ e5 000100 000
XIIIY(a)0.1 g ≤ e ≤ 2 g10010 000
5 g ≤ e50010 000
XIVY(b)5 g ≤ e1001 000

(d)Verification scale interval – multi-interval instruments

Table 10

1 For i = r the corresponding column of Table 9 applies with e replaced by er.

Accuracy classesVerification scale intervalNumber of verification scale intervals n=Max/e
  Minimum value1 n = Maxi/e (i+1)Maximum n=Maxi/ei
XIY(I)0.001 g ≤ ei50 000
XIIY(II)

0.001 g ≤ei≤0.05 g

5 000100 000
0.1 g ≤ ei5 000100 000
XIIIY(a)0.1 g ≤ ei50010 000
XIVY(b)5 g ≤ ei501 000

Where:

(i)i= 1, 2, ...r

(ii)i = partial weighing range

(iii)r = total number of partial ranges

(5) Measurement Range

In specifying the measurement range for class Y instruments the manufacturer shall take account that the minimum capacity shall not be less than:

(a)class Y(I): 100 e

(b)class Y(II): 20 e for 0.001 g ≤ e ≤ 0.05 g, and 50 e for 0.1 g ≤ e

(c)class Y(a): 20 e

(d)class Y(b): 10 e

(e)Scales used for grading, e.g. postal scales and garbage weighers: 5 e

(6) Dynamic setting

(a)The dynamic setting facility shall operate within a load range specified by the manufacturer.

(b)When fitted, a dynamic setting facility that compensates for the dynamic effects of the load in motion shall be inhibited from operating outside the load range, and shall be capable of being secured.

(7) Performance under influence factors and electromagnetic disturbances

(a)The MPEs due to influence factors are—

(i)For category X instruments—

(aa)for automatic operation, as specified in Tables 7 and 8;

(bb)for static weighing in non-automatic operation, as specified in Table 7.

(ii)For category Y instruments—

(aa)for each load in automatic operation, as specified in Table 7;

(bb)for static weighing in non-automatic operation, as specified in category X in Table 7.

(b)The critical change value due to a disturbance is one verification scale interval.

(c)Temperature range

(i)For class XI and Y(I) the minimum range is 5° C.

(ii)For class XII and Y(II) the minimum range is 15° C.

Marginal Citations

M1OJ L 42, 15.2.75, p.1. Directive as last amended by Directive 89/676/EEC (O) L 398, 30.12.89, p. 18).

M2OJ L 46, 21.2.76, p.1. Directive as last amended by the EEA Agreement.

Yn ôl i’r brig

Options/Help

Print Options

Close

Mae deddfwriaeth ar gael mewn fersiynau gwahanol:

Y Diweddaraf sydd Ar Gael (diwygiedig):Y fersiwn ddiweddaraf sydd ar gael o’r ddeddfwriaeth yn cynnwys newidiadau a wnaed gan ddeddfwriaeth ddilynol ac wedi eu gweithredu gan ein tîm golygyddol. Gellir gweld y newidiadau nad ydym wedi eu gweithredu i’r testun eto yn yr ardal ‘Newidiadau i Ddeddfwriaeth’.

Gwreiddiol (Fel y’i Deddfwyd neu y’i Gwnaed): Mae'r wreiddiol fersiwn y ddeddfwriaeth fel ag yr oedd pan gafodd ei deddfu neu eu gwneud. Ni wnaed unrhyw newidiadau i’r testun.

Pwynt Penodol mewn Amser: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

Gweler y wybodaeth ychwanegol ochr yn ochr â’r cynnwys

Rhychwant ddaearyddol: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Dangos Llinell Amser Newidiadau: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Dewisiadau Agor

Dewisiadau gwahanol i agor deddfwriaeth er mwyn gweld rhagor o gynnwys ar y sgrin ar yr un pryd

Close

Memorandwm Esboniadol

Mae Memoranda Esboniadol yn nodi datganiad byr o ddiben Offeryn Statudol ac yn rhoi gwybodaeth am ei amcan polisi a goblygiadau polisi. Maent yn ceisio gwneud yr Offeryn Statudol yn hygyrch i ddarllenwyr nad oes ganddynt gymhwyster cyfreithiol, ac maent yn cyd-fynd ag unrhyw Offeryn Statudol neu Offeryn Statudol Drafft a gyflwynwyd ger bron y Senedd o Fehefin 2004 ymlaen.

Close

Rhagor o Adnoddau

Gallwch wneud defnydd o ddogfennau atodol hanfodol a gwybodaeth ar gyfer yr eitem ddeddfwriaeth o’r tab hwn. Yn ddibynnol ar yr eitem ddeddfwriaeth sydd i’w gweld, gallai hyn gynnwys:

  • y PDF print gwreiddiol y fel deddfwyd fersiwn a ddefnyddiwyd am y copi print
  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • slipiau cywiro
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill
Close

Llinell Amser Newidiadau

This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.

Close

Rhagor o Adnoddau

Defnyddiwch y ddewislen hon i agor dogfennau hanfodol sy’n cyd-fynd â’r ddeddfwriaeth a gwybodaeth am yr eitem hon o ddeddfwriaeth. Gan ddibynnu ar yr eitem o ddeddfwriaeth sy’n cael ei gweld gall hyn gynnwys:

  • y PDF print gwreiddiol y fel gwnaed fersiwn a ddefnyddiwyd am y copi print
  • slipiau cywiro

liciwch ‘Gweld Mwy’ neu ddewis ‘Rhagor o Adnoddau’ am wybodaeth ychwanegol gan gynnwys

  • rhestr o newidiadau a wnaed gan a/neu yn effeithio ar yr eitem hon o ddeddfwriaeth
  • manylion rhoi grym a newid cyffredinol
  • pob fformat o’r holl ddogfennau cysylltiedig
  • dolenni i ddeddfwriaeth gysylltiedig ac adnoddau gwybodaeth eraill