- Latest available (Revised)
- Original (As made)
This is the original version (as it was originally made). This item of legislation is currently only available in its original format.
A route, about 1330 metres in length, commencing at a point on the M6 Motorway 40 metres south of the point where it crosses the centre of Warrington Road, Lymm in the County of Cheshire (marked “A” on the deposited plan) and proceeding in a generally northerly direction to rejoin that Motorway at a point 380 metres south of the point where it crosses the centre of Manchester Road, Warrington in the County of Cheshire (marked “B” on the deposited plan).
1. A route from the northbound carriageway of the M6 Motorway to a new roundabout to be constructed on the A50 Cliff Lane (west of the existing roundabout). This new slip road is given the reference number 1 on the deposited plan.
2. A route from the westbound carriageway and a route from the eastbound carriageway of the M62 Motorway to the southbound carriageway of the M6 Motorway. These new slip roads are given the reference numbers 2 and 3, respectively, on the deposited plan.
From a point south of the centreline of the Manchester Ship Canal in the Borough of Warrington in the County of Cheshire 65 metres north east from the centre of the northern face of the Thelwall Viaduct pier on the southern bank of the canal and 79 metres south east from the centre of the southern face of the Thelwall Viaduct pier on the northern bank of the canal.
To a point north of the centreline of the Manchester Ship Canal 106 metres north east from the centre of the northern face of the Thelwall Viaduct pier on the southern bank of the canal and 53 metres east from the centre of the southern face of the Thelwall Viaduct pier on the northern bank of the canal.
Composite steel girder and reinforced concrete deck on reinforced concrete piers.
22.86 metres minimum headroom above statutory water level above canal fairway tapering to 20.62 metres above statutory water level 5.64 metres from the edge of the fairway.
This would have the effect of diverting the southern bank of the waterway northwards by a maximum distance of 16 metres and the northern bank of the waterway southwards by a maximum distance of 14 metres. The existing waterway width of 79 metres would be reduced to a minimum width of 48.76 metres.
From a point south of the centreline of the River Mersey in the Borough of Warrington in the County of Cheshire 45 metres north of the north east corner of the pilecap of Thelwall Viaduct Pier HH and 93 metres south east of the north east corner of the eastern wingwall of the northern abutment of Thelwall Viaduct.
To a point north of the centreline of the River Mersey 88 metres north of the north east corner of the pilecap of Thelwall Viaduct pier HH and 49 metres south east of the north east corner of the eastern wingwall of the northern abutment of Thelwall Viaduct.
Composite steel girder and reinforced concrete deck on reinforced concrete piers.
Headroom to be not less than 9.12m above normal navigation level which is 8.41m above Ordnance Datum to be maintained for a distance of 22 metres each side of the centreline of the navigable waterway.
As defined by the above limits at normal navigation level.
This would have the effect of diverting the southern bank of the waterway northwards by a maximum distance of 6 metres. The existing waterway width of 50 metres would be reduced to a minimum width of 44 metres.
From a point south of the centreline of the Bridgewater Canal in the Borough of Warrington in the County of Cheshire 25 metres south west from the easternmost column of the northern pier of the Bridgewater Canal Bridge and 23 metres south east from the westernmost column of the northern pier of the Bridgewater Canal Bridge.
To a point north of the centreline of the Bridgewater Canal 15 metres north west from the easternmost column of the southern pier of the Bridgewater Canal Bridge and 34 metres north east from the westernmost column of the southern pier of the Bridgewater Canal Bridge.
Composite steel girder and reinforced concrete deck on reinforced concrete piers.
3.7 metres minimum headroom above Normal Canal Water Level.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include: