- Latest available (Revised)
- Point in Time (01/01/2015)
- Original (As adopted by EU)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.
the OIEISS,
the weak positive OIE ELISA standard serum (OIEELISA WP SS),
the strong positive OIE ELISA standard serum (OIEELISA SP SS),
the negative OIE ELISA standard serum (OIEELISA N SS).
the weak positive OIE ELISA standard serum (OIEELISA WP SS),
the strong positive OIE ELISA standard serum (OIEELISA SP SS),
the negative OIE ELISA standard serum (OIEELISA N SS).
The technique used and the interpretation of results must have been validated in accordance with the principles laid down in Chapter 1.1.4 of the OIE Manual of Diagnostic Tests and Vaccines for Terrestrial Animals, Sixth Edition, 2008, and must include at least laboratory and diagnostic studies.
a 1/150 pre-dilution (1) of the OIEISS or a 1/2 pre-dilution of the OIEELISA WP SS or a 1/16 pre-dilution of the OIEELISA SP SS made up in a negative serum (or in a negative pool of sera) must give a positive reaction;
a 1/600 pre-dilution of the OIEISS or a 1/8 pre-dilution of the OIEELISA WP SS or a 1/64 pre-dilution of the OIEELISA SP SS made up in a negative serum (or in a negative pool of sera) must give a negative reaction;
the OIEELISA N SS must always give a negative reaction.
a 1/150 pre-dilution of the OIEISS or a 1/2 pre-dilution of the OIEELISA WP SS or a 1/16 pre-dilution of the OIEELISA SP SS made up in a negative serum (or in a negative pool of sera) and again diluted in negative sera by the number of samples making up the pool must give a positive reaction;
the OIEELISA N SS must always give a negative reaction;
the test must be adequate to detect evidence of infection in a single animal of the group of animals, of which samples of serum have been pooled.
a 1/ 1 000 pre-dilution of the OIEISS or a 1/16 pre-dilution of the OIEELISA WP SS or a 1/125 pre-dilution of the OIEELISA SP SS made up in a negative serum (or in a negative pool of sera) and again diluted 1/10 in negative milk must give a positive reaction;
the OIEELISA N SS diluted 1/10 in negative milk must always give a negative reaction;
the test must be adequate to detect evidence of infection in a single animal of the group of animals, of which samples of milk or whey have been pooled.
bovine serum: 56 to 60 °C for 30 to 50 minutes,
porcine serum: 60 °C for 30 to 50 minutes.
control of the anti-complementary effect of the serum;
control of the antigen;
control of sensitised red blood cells;
control of the complement;
control using a positive serum of sensitivity at the start of the reaction;
control of the specificity of the reaction using a negative serum.
The OIEISS contains 1 000 international CFT units (ICFTU) per ml. If the OIEISS is tested in a given method the result is given as a titre (i.e. highest direct dilution of the OIEISS giving 50 % haemolysis, T OIEISS ). The test result for the test serum given as titre (T TESTSERUM ) must be expressed in ICFTU per ml. In order to convert the expression of a titre into ICFTU, the factor (F) necessary to convert a titre of an unknown test serum (T TESTSERUM ) tested by that method into the ICFTU expression can be found from the formula:
F = 1 000 × 1/T OIEISS
and the content of international CFT units per ml of test serum (ICFTU TESTSERUM ) from the formula:
ICFTU TESTSERUM = F × T TESTSERUM
A serum containing 20 or more ICFTU per ml shall be considered to be positive.
on a column of milk of at least 25 mm height and on a volume of milk of 1 ml to which either 0,03 ml or 0,05 ml of one of the standardised stained antigens has been added,
on a column of milk of at least 25 mm height and on a volume of milk of 2 ml to which 0,05 ml of one of the standardised stained antigens has been added,
on a volume of milk of 8 ml to which 0,08 ml of one of the standardised stained antigens has been added.
negative reaction: coloured milk, colourless cream;
positive reaction:
identically coloured milk and cream, or
colourless milk and coloured cream.
serum (20-30 μl) is mixed with an equal volume of antigen on a white tile or enamel plate to produce a zone approximately 2 cm in diameter. The mixture is rocked gently for four minutes at ambient temperature, and then observed in a good light for agglutination;
an automated method may be used but must be at least as sensitive and accurate as the manual method.
Any visible reaction shall be considered to be positive, unless there has been excessive drying round the edges.
Positive and negative working standards shall be included in each series of tests.
Formaldehyde must not be used.
Antigens may be delivered in the concentrated state provided the dilution factor to be used is indicated on the bottle label.
EDTA may be added to the antigen suspension to 5 mM final test dilution to reduce the level of false positives to the serum agglutination test. Subsequently the pH of 7.2 must be readjusted in the antigen suspension.
It may also be advisable to compare the reactivity of new and previously standardised batches of antigen using a panel of defined sera.
At least three dilutions must be prepared for each serum. Dilutions of suspect serum must be made in such a way that reading of the reaction at the positivity limit is made in the median tube (or well for the microplate method).
The degree of Brucella agglutination in a serum must be expressed in IU per ml.
A serum containing 30 or more IU per ml is considered to be positive.
The FPA shall be standardised so that:
the OIEELISA SP SS and OIEELISA WP SS consistently give positive results.
a 1/8 pre-dilution of the OIEELISA WP SS or a 1/64 pre-dilution of the OIEELISA SP SS made up in a negative serum (or in a negative pool of sera) always gives a negative reaction;
the OIEELISA N SS always gives a negative reaction.
The following shall be included in each batch of tests: a strong positive, a weak positive, a negative working standard serum (calibrated against the OIE ELISA Standard Sera).] ] ]
Textual Amendments
F1 Substituted by Council Directive 97/12/EC of 17 March 1997 amending and updating Directive 64/432/EEC on health problems affecting intra-Community trade in bovine animals and swine.
Textual Amendments
F1 Substituted by Council Directive 97/12/EC of 17 March 1997 amending and updating Directive 64/432/EEC on health problems affecting intra-Community trade in bovine animals and swine.
The Whole Directive you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.
The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.
For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: