- Latest available (Revised)
- Point in Time (28/03/2006)
- Original (As adopted by EU)
Directive 97/24/EC of the European Parliament and of the Council of 17 June 1997 on certain components and characteristics of two or three-wheel motor vehicles (repealed)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
Version Superseded: 01/01/2016
EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.
ANNEX I | Build requirements … |
Appendix 1 | Test equipment … |
Appendix 2 | Information document in respect of a fuel tank type for a two or three-wheel motor vehicle … |
Appendix 3 | Component type-approval certificate in respect of a fuel tank type for a two or three-wheel motor vehicle … |
ANNEX II | Requirements concerning the fitting of fuel tanks and fuel supply systems to two or three-wheel motor vehicles … |
Appendix 1 | Information document in respect of the fitting of a fuel tank or tanks to a type of two or three-wheel motor vehicle … |
Appendix 2 | Vehicle type-approval certificate in respect of the fitting of a fuel tank or tanks to a type of two or three-wheel motor vehicle …] |
Fuel tanks made of anything other than metal are tested as described below and in the order shown:
The fuel tank must be tested at a temperature of 313 K ± 2 K. The test fuel to be used in the reference fuel defined in chapter 5 on measures to counter atmospheric pollution by two or three-wheel motor vehicles.
The tank is filled up to 50 % of its rated capacity with the test fuel and allowed to rest in the ambient air at a temperature of 313 K ± 2 K until there is a constant weight loss. That period must be at least four weeks (pre-storage period). The tank is emptied and then refilled to 50 % of its rated capacity with test fuel.
The tank is then stored under the stabilizing conditions at a temperature of 313 K ± 2 K until its contents are at the test temperature. The tank is then closed. The pressure rise in the tank during the test may be compensated. The weight loss due to diffusion must be determined during the eight-week test. During that test a maximum quantity of 20 g may escape, on average, every 24 hours. If the diffusion losses are greater, the fuel loss must also be determined at a test temperature of 296 K ± 2 K, all other conditions being maintained (pre-storage at 313 K ± 2 K). The loss determined under those conditions must not exceed 10 g per 24 hours.
When the test it conducted with internal pressure compensation, which must be mentioned in the test report, the fuel loss resulting from the pressure compensation must be taken into account when the diffusion loss is established.
The fuel tank is filled up to its nominal capacity with a mixture of 50 % water and ethylene glycol or with any other coolant which does not attack the fuel tank material, the cryoscopic point of which is lower than 243 K ± 2 K.
The temperature of the substances contained in the fuel tank during the test must be 253 K ± 5 K. The tank is cooled down at a corresponding ambient temperature. It is also possible to fill the fuel tank with a suitably refrigerated liquid provided that the fuel tank is left at the test temperature for at least an hour.
A pendulum is used for the test. Its impact head must take the form of an equilateral triangular pyramid having a radius of curvature of 3,0 mm at its peaks and edges. With a mass of 15 kg the pendulum's energy may not be less than 30,0 J.
The points on the fuel tank to be tested must be those considered at risk as a result of the fitting of the tank and its position on the vehicle. There must be no liquid leakage following a single impact at one of those points.
The fuel tank is filled up to its rated capacity, the test liquid used being water at 326 K ± 2 K. The relative internal pressure must not be less than 30 kPa. Where the fuel tank has been designed to withstand relative internal pressure of use greater than 15 kPa, the relative test pressure to be applied must be double the relative internal use pressure for which the tank has been designed. The tank must remain closed for a period of 5 hours.
Any deformation which may arise may not render the fuel tank unusable. (For example, the tank must not be perforated). Account must be taken of specific fitting conditions if the deformation of the tank is to be assessed.
Six tensile test-pieces of approximately the same thickness are taken from the flat faces. Their tensile strength and elastic limits are established at 296 K ± 2 K at an elongation rate of 50 mm/min. These values must be compared with the tensile strength and elasticity values obtained via similar tests using a fuel tank that has already been stored for the pre-storage period. The material must be considered to be acceptable if there has been no difference in tensile strength of more than 25 %.
The tank material must not burn at a flame speed greater than 0,64 mm/s in the test set out in Appendix 1.
The fuel tank, filled to 50 % of its rated capacity with water at 293 K ± 2 K, must not display plastic deformation or leaks after storage for one hour at an ambient temperature of 343 K ± 2 K. After the test, the tank must always be fully usable. The testing device must take account of the fitting conditions.
A totally enclosed laboratory fume hood with a heat-resistant test-observation window. A mirror may be used in certain test enclosures in order to provide a rear view of the sample.
The fume extractor fan must be shut down during the test and restarted immediately after the test in order to remove any toxic combustion products.
The test may also be carried out inside a metal box placed beneath the fume hood with the extractor fan operating.
The top and bottom walls of the box must incorporate ventilation holes enabling sufficient air for the combustion to pass through while not subjecting the burning sample to a draught.
A laboratory supporting base including two grips which can be set in any position by means of swivel joints.
A gas-fired Bunsen (or Tirill) type with a 10 mm nozzle.
The nozzle must not be fitted with any accessory.
Mesh size 20. Square of 100 × 100 mm.
A timer or similar device with divisions not greater than 1 second.
Graduation in millimetres.
If otherwise prevented by the shape of the fuel tank, part of the tank must be moulded into a plate that is 3 mm thick and sufficient in area to enable the necessary samples to be taken.
A bath full of water must be placed on the fume hood table in such a way as to receive any incandescent particles which may fall during the test.
The flame is held in contact for 30 seconds and if the sample deforms, melts or shrinks away from the flame, the flame must be moved in order to maintain contact with the sample.
Significant deformation of the sample during the test may invalidate the result. The burner must be withdrawn after 30 seconds or when the flame front reaches the 25 mm mark. If it reaches this earlier the burner must be moved at least 450 mm away from the sample and the fume hood closed.
The burnt length must be equal to 100 mm less the unburnt length expressed in mm.
If one sample out of 10 burns up to the 100 mm mark or beyond, the test (3.1 to 3.8) is repeated on 10 new samples.
where n is the number of samples
rounded up or down to the nearest 5-second multiple: thus ‘less than 5 seconds’ must be stated if combustion lasts less than 3 seconds following withdrawal of the burner.
In no case must an ACT of 0 be given.
where n is the number of samples
rounded up or down to the nearest multiple of 5 mm; where there are combustion lengths of less than 3 mm state ‘less than 5 mm’.
In no case must an ACL of 0 be given.
Where a single sample burns up to the mark the combustion length is counted as 100 mm.
Tank attachment systems must be designed, manufactured and installed in such a way as to fulfil their function whatever the driving conditions.
Engine fuel-system components must be suitably protected by a part of the frame or bodywork in such a way that they cannot strike against obstacles on the ground. That protection is not required if the components in question, when located beneath the vehicle, are further from the ground than the part of the frame or bodywork that is located immediately ahead of them.
The fuel-supply system must be designed, manufactured and installed in such a way as to withstand the effects of any internal and external corrosion to which it is exposed. No motion due to torsion, flexing and vibration of the vehicle structure, engine and transmission must subject fuel-system components to abnormal friction or stressing.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.
The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.
For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: