- Latest available (Revised)
- Point in Time (15/02/2006)
- Original (As adopted by EU)
Directive 2006/7/EC of the European Parliament and of the Council of 15 February 2006 concerning the management of bathing water quality and repealing Directive 76/160/EEC
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.
a Based upon a 95‐percentile evaluation. See Annex II. | |||||
b Based upon a 90‐percentile evaluation. See Annex II. | |||||
A | B | C | D | E | |
---|---|---|---|---|---|
Parameter | Excellent quality | Good quality | Sufficient | Reference methods of analysis | |
1 | Intestinal enterococci (cfu/100 ml) | 200a | 400a | 330b | ISO 7899-1 or ISO 7899-2 |
2 | Escherichia coli (cfu/100 ml) | 500a | 1 000a | 900b | ISO 9308-3 or ISO 9308-1 |
a Based upon a 95‐percentile evaluation. See Annex II. | |||||
b Based upon a 90‐percentile evaluation. See Annex II. | |||||
A | B | C | D | E | |
---|---|---|---|---|---|
Parameter | Excellent quality | Good quality | Sufficient | Reference methods of analysis | |
1 | Intestinal enterococci (cfu/100 ml) | 100a | 200a | 185b | ISO 7899-1 or ISO 7899-2 |
2 | Escherichia coli (cfu/100 ml) | 250a | 500a | 500b | ISO 9308-3 or ISO 9308-1 |
Bathing waters are to be classified as ‘poor’ if, in the set of bathing water quality data for the last assessment period(1), the percentile values(2) for microbiological enumerations are worse(3) than the ‘sufficient’ values set out in Annex I, column D.
Bathing waters are to be classified as ‘sufficient’:
if, in the set of bathing water quality data for the last assessment period, the percentile values for microbiological enumerations are equal to or better(4) than the ‘sufficient’ values set out in Annex I, column D; and
if the bathing water is subject to short-term pollution, on condition that:
adequate management measures are being taken, including surveillance, early warning systems and monitoring, with a view to preventing bathers' exposure by means of a warning or, where necessary, a bathing prohibition;
adequate management measures are being taken to prevent, reduce or eliminate the causes of pollution; and
the number of samples disregarded in accordance with Article 3(6) because of short‐term pollution during the last assessment period represented no more than 15 % of the total number of samples provided for in the monitoring calendars established for that period, or no more than one sample per bathing season, whichever is the greater.
Bathing waters are to be classified as ‘good’:
if, in the set of bathing water quality data for the last assessment period, the percentile values for microbiological enumerations are equal to or better(4) than the ‘good quality’ values set out in Annex I, column C; and
if the bathing water is subject to short-term pollution, on condition that:
adequate management measures are being taken, including surveillance, early warning systems and monitoring, with a view to preventing bathers' exposure, by means of a warning or, where necessary, a bathing prohibition;
adequate management measures are being taken to prevent, reduce or eliminate the causes of pollution; and
the number of samples disregarded in accordance with Article 3(6) because of short‐term pollution during the last assessment period represented no more than 15 % of the total number of samples provided for in the monitoring calendars established for that period, or no more than one sample per bathing season, whichever is the greater.
Bathing waters are to be classified as ‘excellent’:
if, in the set of bathing water quality data for the last assessment period, the percentile values for microbiological enumerations are equal to or better than the ‘excellent quality’ values set out in Annex I, column B; and
if the bathing water is subject to short-term pollution, on condition that:
adequate management measures are being taken, including surveillance, early warning systems and monitoring, with a view to preventing bathers' exposure, by means of a warning or, where necessary, a bathing prohibition;
adequate management measures are being taken to prevent, reduce or eliminate the causes of pollution; and
the number of samples disregarded in accordance with Article 3(6) because of short‐term pollution during the last assessment period represented no more than 15 % of the total number of samples provided for in the monitoring calendars established for that period, or no more than one sample per bathing season, whichever is the greater.
NOTES
a description of the physical, geographical and hydrological characteristics of the bathing water, and of other surface waters in the catchment area of the bathing water concerned, that could be a source of pollution, which are relevant to the purpose of this Directive and as provided for in Directive 2000/60/EC;
an identification and assessment of causes of pollution that might affect bathing waters and impair bathers' health;
an assessment of the potential for proliferation of cyanobacteria;
an assessment of the potential for proliferation of macro-algae and/or phytoplankton;
if the assessment under point (b) shows that there is a risk of short-term pollution, the following information:
the anticipated nature, frequency and duration of expected short-term pollution,
details of any remaining causes of pollution, including management measures taken and the time schedule for their elimination,
management measures taken during short-term pollution and the identity and contact details of bodies responsible for taking such action,
the location of the monitoring point.
Bathing water classification | ‘Good’ | ‘Sufficient’ | ‘Poor’ |
---|---|---|---|
Reviews are to take place at least every | four years | three years | two years |
Aspects to be reviewed (points of paragraph 1) | (a) to (f) | (a) to (f) | (a) to (f) |
In the case of bathing waters previously classified as ‘excellent’, the bathing water profiles need be reviewed and, if necessary, updated only if the classification changes to ‘good’, ‘sufficient’ or ‘poor’. The review is to cover all aspects mentioned in paragraph 1.
has a bathing season not exceeding eight weeks; or
is situated in a region subject to special geographical constraints.
Where possible, samples are to be taken 30 centimetres below the water's surface and in water that is at least one metre deep.
Sample bottles are:
to undergo sterilisation in an autoclave for at least 15 minutes at 121 oC, or
to undergo dry sterilisation at between 160 oC and 170 oC for at least one hour, or
to be irradiated sample containers obtained directly from manufacturer.
The volume of the sampling bottle/container is to depend on the quantity of water needed for each parameter to be tested. The minimum content is generally 250 ml.
Sample containers are to be of transparent and non-coloured material (glass, polyethene or polypropylene).
In order to prevent accidental contamination of the sample, the sampler is to employ an aseptic technique to maintain the sterility of the sample bottles. There is no further need for sterile equipment (such as sterile surgical gloves or tongs or sample pole) if this is done properly.
The sample is to be clearly identified in indelible ink on the sample and on the sampling form.
Water samples are to be protected at all stages of transport from exposure to light, in particular direct sunlight.
The sample is to be conserved at a temperature of around 4 oC, in a cool box or refrigerator (depending on climate) until arrival at the laboratory. If the transport to the laboratory is likely to take more than four hours, then transport in a refrigerator is required.
The time between sampling and analysis is to be kept as short as possible. It is recommended that samples be analysed on the same working day. If this is not possible for practical reasons, then the samples shall be processed within no more than 24 hours. In the meantime, they shall be stored in the dark and at a temperature of 4 oC ± 3 oC.
‘Last assessment period’ means the last four bathing seasons or, when applicable, the period specified in Article 4(2) or (4).
Based upon percentile evaluation of the log10 normal probability density function of microbiological data acquired from the particular bathing water, the percentile value is derived as follows:
Take the log10 value of all bacterial enumerations in the data sequence to be evaluated. (If a zero value is obtained, take the log10 value of the minimum detection limit of the analytical method used instead.)
Calculate the arithmetic mean of the log10 values (μ).
Calculate the standard deviation of the log10 values (σ).
The upper 90‐percentile point of the data probability density function is derived from the following equation: upper 90‐percentile = antilog (μ + 1,282 σ).
The upper 95‐percentile point of the data probability density function is derived from the following equation: upper 95‐percentile = antilog (μ + 1,65 σ).
‘Worse’ means with higher concentration values expressed in cfu/100 ml.
‘Better’ means with lower concentration values expressed in cfu/100 ml.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.
The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.
For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: