- Latest available (Revised)
- Original (As adopted by EU)
Commission Directive (EU) 2015/1480 of 28 August 2015 amending several annexes to Directives 2004/107/EC and 2008/50/EC of the European Parliament and of the Council laying down the rules concerning reference methods, data validation and location of sampling points for the assessment of ambient air quality (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
EU Directives are published on this site to aid cross referencing from UK legislation. Since IP completion day (31 December 2020 11.00 p.m.) no amendments have been applied to this version.
Directive 2004/107/EC is amended as follows:
Section I of Annex IV is amended as follows:
the table is replaced by the following:
a Distributed over the year to be representative of various conditions for climate and anthropogenic activities | ||||
b Indicative measurement being measurements which are performed at reduced regularity but fulfil the other data quality objectives’ | ||||
‘Benzo(a)pyrene | Arsenic, cadmium and nickel | Polycyclic aromatic hydrocarbons other than benzo(a)pyrene, total gaseous mercury | Total deposition | |
---|---|---|---|---|
— Uncertainty | ||||
Fixed and indicative measurements | 50 % | 40 % | 50 % | 70 % |
Modelling | 60 % | 60 % | 60 % | 60 % |
— Minimum data capture | 90 % | 90 % | 90 % | 90 % |
— Minimum time coverage | ||||
Fixed measurementsa | 33 % | 50 % | ||
Indicative measurementsa b | 14 % | 14 % | 14 % | 33 % |
in the third paragraph, the following sentence is deleted:
‘Twenty-four hour sampling is also advisable for the measurement of arsenic, cadmium and nickel concentrations.’
after the third paragraph the following text is inserted:
‘The provisions on individual samples in the previous paragraph apply also to arsenic, cadmium, nickel and total gaseous mercury. Moreover, sub–sampling of PM10 filters for metals for subsequent analysis is allowed, providing there is evidence that the sub-sample is representative of the whole and that the detection sensitivity is not compromised when compared with the relevant data quality objectives. As an alternative to daily sampling, weekly sampling for metals in PM10 is allowed provided that the collection characteristics are not compromised.’
Sections I to IV of Annex V are replaced by the following:
The reference method for the sampling of arsenic, cadmium and nickel in ambient air is described in EN 12341:2014. The reference method for the measurement of arsenic, cadmium and nickel in ambient air is that described in EN 14902:2005 “Ambient air quality — Standard method for the measurement of Pb, Cd, As and Ni in the PM10 fraction of suspended particulate matter”.
A Member State may also use any other methods which it can demonstrate give results equivalent to the above method.
The reference method for the sampling of polycyclic aromatic hydrocarbons in ambient air is described in EN 12341:2014. The reference method for the measurement of benzo(a)pyrene in ambient air is that described in EN 15549:2008 “Air quality — Standard method for the measurement of concentration of benzo[a]pyrene in ambient air”. In the absence of a CEN standard method for the other polycyclic aromatic hydrocarbons referred to in Article 4(8), Member States are allowed to use national standards methods or ISO methods such as ISO standard 12884.
A Member State may also use any other method which it can demonstrate give results equivalent to the above method.
The reference method for the measurement of total gaseous mercury concentrations in ambient air is that described in EN 15852:2010 “Ambient air quality — Standard method for the determination of total gaseous mercury”.
A Member State may also use any other method which it can demonstrate give results equivalent to the above method.
The reference method for the determination of the deposition of arsenic, cadmium, and nickel is that described in EN 15841:2009 “Ambient air quality — Standard method for determination of arsenic, cadmium, lead and nickel in atmospheric deposition”.
The reference method for the determination of the deposition of mercury is that described in EN 15853:2010 “Ambient air quality — Standard method for determination of mercury deposition”.
The reference method for the determination of the deposition of benzo(a)pyrene and the other polycyclic hydrocarbons referred to in Article 4(8) is that described in EN 15980:2011 “Air quality. Determination of the deposition of benz[a]anthracene, benzo[b]fluoranthene, benzo[j]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, dibenz[a,h]anthracene and indeno[1,2,3-cd]pyrene”.’
Directive 2008/50/EC is amended as follows:
Section C of Annex I is replaced by the following:
that all measurements undertaken in relation to the assessment of ambient air quality pursuant to Articles 6 and 9 are traceable in accordance with the requirements set out in the harmonised standard for testing and calibration laboratories,
that institutions operating networks and individual stations have an established quality assurance and quality control system which provides for regular maintenance to assure the continued accuracy of measuring devices. The quality system shall be reviewed as necessary and at least every five years by the relevant National Reference Laboratory
that a quality assurance/quality control process is established for the process of data collection and reporting and that institutions appointed for this task actively participate, in the related Union-wide quality assurance programmes,
that the National Reference Laboratories are appointed by the appropriate competent authority or body designated pursuant to Article 3 and are accredited for the reference methods referred to in Annex VI, at least for those pollutants for which concentrations are above the lower assessment threshold, according to the relevant harmonised standard for testing and calibration laboratories, the reference to which has been published in the Official Journal of the European Union pursuant to Article 2(9) of Regulation (EC) No 765/2008 setting out the requirements for accreditation and market surveillance. These laboratories shall also be responsible for the coordination in Member State's territory of the Union-wide quality assurance programmes to be organised by the Commission's Joint Research Centre and shall also be responsible for coordinating, on the national level, the appropriate use of reference methods, and the demonstration of equivalence of non-reference methods. National Reference Laboratories organising intercomparison on the national level should also be accredited according to the relevant harmonised standard for proficiency testing.
that the National Reference Laboratories, take part at least every three years in the Union-wide quality assurance programmes organized by the Commission's Joint Research Centre. If this participation produces unsatisfactory results then the national laboratory should demonstrate at the next participation in the intercomparison satisfactory remediation measures, and provide a report to the Joint Research Centre on these.
that the national reference laboratories support the work done by the European network of National Reference Laboratories set up by the Commission.
Annex III is amended as follows:
Section C is amended as follows:
the first and the second indents of paragraph 1 are replaced by the following:
‘the flow around the inlet sampling probe shall be unrestricted (in general free in an arc of at least 270° or 180° for sampling points at the building line) without any obstructions affecting the airflow in the vicinity of the inlet (normally some metres away from buildings, balconies, trees and other obstacles and at least 0,5 m from the nearest building in the case of sampling points representing air quality at the building line)
in general, the inlet sampling point shall be between 1,5 m (the breathing zone) and 4 m above the ground. Higher siting may also be appropriate if the station is representative of a large area and any derogations should be fully documented;’
the fifth indent of paragraph 1 is replaced by the following:
‘for all pollutants, traffic-orientated sampling probes shall be at least 25 m from the edge of major junctions and no more than 10 m from the kerbside. A “major junction” to be considered here is a junction which interrupts the traffic flow and causes different emissions (stop&go) from the rest of the road.’
the following paragraph is added:
‘Any deviation from the criteria listed in this Section shall be fully documented through the procedures described in Section D.’
Section D is replaced by the following:
The competent authorities responsible for air quality assessment shall for all zones and agglomerations fully document the site-selection procedures and record information to support the network design and choice of location for all monitoring sites. The documentation shall include compass-point photographs of the area surrounding monitoring sites and detailed maps. Where supplementary methods are used within a zone or agglomeration, the documentation shall include details of these methods and information on how the criteria listed in Article 7(3) are met. The documentation shall be updated as necessary and reviewed at least every 5 years, to ensure that selection criteria, network design and monitoring site locations remain valid and optimal over time. The documentation shall be provided to the Commission within 3 months of being requested.’
Annex VI is amended as follows:
Section A is replaced by the following:
The reference method for the measurement of sulphur dioxide is that described in EN 14212:2012 “Ambient air — Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence”.
The reference method for the measurement of nitrogen dioxide and oxides of nitrogen is that described in EN 14211:2012 “Ambient air — Standard method for the measurement of the concentration of nitrogen dioxide and nitrogen monoxide by chemiluminescence”.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The reference method for the sampling and measurement of PM10 is that described in EN12341:2014 “Ambient Air — standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter”.
The reference method for the sampling and measurement of PM2,5 is that described in EN12341:2014 “Ambient Air — standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter”
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The reference method for the measurement of carbon monoxide is that described in EN 14626:2012 “Ambient air — Standard method for the measurement of the concentration of carbon monoxide by non-dispersive infrared spectroscopy”.
The reference method for the measurement of ozone is that described in EN 14625:2012 “Ambient air — Standard method for the measurement of the concentration of ozone by ultraviolet photometry”.’
Section D is deleted;
Section E is replaced by the following:
‘When demonstrating that equipment meets the performance requirements of the reference methods listed in Section A of this Annex, the competent authorities and bodies designated pursuant to Article 3 shall accept test reports issued in other Member States provided that the test laboratories are accredited to the relevant harmonised standard for testing and calibration laboratories.
The detailed test reports and all the results of the tests shall be available to other competent authorities or their designated bodies. Test reports shall demonstrate that the equipment meets all the performance requirements including where some environmental and site conditions are specific to a Member State and are outside the conditions for which the equipment has been already tested and type approved in another Member State;’
Section A of Annex IX is replaced by the following:
Minimum number of sampling points for fixed continuous measurements to assess compliance with target values, long — term objectives and information and alert thresholds where such measurements are the sole source of information.
a At least 1 station in areas where exposure of the population to the highest concentrations of ozone is likely to occur. In agglomerations, at least 50 % of the stations shall be located in suburban areas. | |||
b 1 station per 25 000 km2 for complex terrain is recommended.’ | |||
Population (× 1 000) | Agglomerationa | Other zonesa | Rural background |
---|---|---|---|
< 250 | 1 | 1 station/50 000 km2 as an average density over all zones per countryb | |
< 500 | 1 | 2 | |
< 1 000 | 2 | 2 | |
< 1 500 | 3 | 3 | |
< 2 000 | 3 | 4 | |
< 2 750 | 4 | 5 | |
< 3 750 | 5 | 6 | |
> 3 750 | One additional station per 2 million inhabitants | One additional station per 2 million inhabitants |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
This timeline shows the different versions taken from EUR-Lex before exit day and during the implementation period as well as any subsequent versions created after the implementation period as a result of changes made by UK legislation.
The dates for the EU versions are taken from the document dates on EUR-Lex and may not always coincide with when the changes came into force for the document.
For any versions created after the implementation period as a result of changes made by UK legislation the date will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. For further information see our guide to revised legislation on Understanding Legislation.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: