Commission Regulation (EU) No 347/2010 of 21 April 2010 amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps (Text with EEA relevance)
When the UK left the EU, legislation.gov.uk published EU legislation that had been published by the EU up to IP completion day (31 December 2020 11.00 p.m.). On legislation.gov.uk, these items of legislation are kept up-to-date with any amendments made by the UK since then.
Legislation.gov.uk publishes the UK version. EUR-Lex publishes the EU version. The EU Exit Web Archive holds a snapshot of EUR-Lex’s version from IP completion day (31 December 2020 11.00 p.m.).
This is the original version as it was originally adopted in the EU.
This legislation may since have been updated - see the latest available (revised) version
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products(1), and in particular Article 15(1) thereof,
After consulting the Ecodesign Consultation Forum,
Whereas:
(1) After the adoption of Commission Regulation (EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and of the Council(2), it appeared that certain provisions of that Regulation should be amended in order to avoid unintended impacts on the availability and performance of the products covered by that Regulation.
(2) In addition, it is necessary to improve coherence, as regards the requirements on product information, between on the one hand Regulation (EC) No 245/2009 and on the other hand Commission Regulation (EC) No 244/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for non-directional household lamps(3).
(3) The measures provided for in this Regulation are in accordance with the opinion of the Committee established by Article 19(1) of Directive 2009/125/EC,
HAS ADOPTED THIS REGULATION:
Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as set out in the Annex to this Regulation.
This Regulation shall enter into force on the first day following its publication in the Official Journal of the European Union.
It shall apply from 13 April 2010.
This Regulation shall be binding in its entirety and directly applicable in all Member States.
Done at Brussels, 21 April 2010.
For the Commission
The President
José Manuel Barroso
Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as follows:
Annex I is amended as follows:
the title is replaced by the following:
‘Exemptions’;
the introductory sentence in point 1 is replaced by the following:
‘The following lamps shall be exempt from the provisions of Annex III, provided that the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC states which of the technical parameters listed hereunder provide(s) a basis for their exemption:’;
points 1(c) and 1(d) are replaced by the following:
blended high intensity discharge lamps having:
6 % or more of total radiation of the range 250-780 nm in the range of 250-400 nm; and
11 % or more of total radiation of the range 250-780 nm in the range of 630-780 nm; and
5 % or more of total radiation of the range 250-780 nm in the range of 640-700 nm;
blended high intensity discharge lamps having:
the peak of the radiation between 315-400 nm (UVA) or 280-315 nm (UVB);’;
point 2 is replaced by the following:
products intended for use in applications other than general lighting and products incorporated into products which do not provide a general lighting function;
lamps covered by the requirements of Directives 94/9/EC of the European Parliament and of the Council(4) or Directive 1999/92/EC of the European Parliament and of the Council(5);
emergency lighting luminaires and emergency sign luminaires within the meaning of Directive 2006/95/EC of the European Parliament and of the Council(6).
ballasts intended for use in luminaires defined in paragraph (c) and designed to operate lamps in emergency conditions;
The intended purpose shall be stated for each product in the product information, and the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC shall list the technical parameters that make the product design specific for the stated intended purpose.’
Annex II is amended as follows:
the first sentence is deleted;
The following sentence is added to point 1(c):
‘For the purposes of Table 6 in Annex III, the LSF shall be measured in high frequency operating mode with a switching cycle of 11h/1h.’
The following point (o) is added to point 3:
“Blended lamp” means a lamp containing a mercury vapour lamp and an incandescent lamp filament connected in series in the same bulb.’
Annex III is amended as follows:
The following paragraph is added before Table 1:
‘Spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) shall comply with the requirements set out in Table 5 for T9 circular lamps.’
Table 2 is replaced by the following:
Rated minimum efficacy values for single capped fluorescent lamps working on electromagnetic and electronic ballast
Table 3 is replaced by the following:
Rated minimum efficacy values for single capped fluorescent lamps, working only on electronic ballast
Table 6 is replaced by the following:
Deduction percentages for rated minimum efficacy values for fluorescent lamps with high colour temperature and/or high colour rendering and/or second lamp envelope and/or long life
Lamp parameter | Deduction from luminous efficacy at 25 °C |
---|---|
Tc ≥ 5 000 K | -10 % |
95 ≥ Ra > 90 | -20 % |
Ra > 95 | -30 % |
Second lamp envelope | -10 % |
Lamp Survival Factor ≥ 0,50 after 40 000 burning hours | -5 %’ |
In Annex III.1.1.B, the sentence
‘The corrections defined for the first stage (Table 6) shall continue to apply’
is replaced by
‘The corrections (Table 6) and the specific requirements for spiral-shaped double capped fluorescent lamps defined for the first stage shall continue to apply.’;
The title of Table 7 is replaced by the following:
‘Table 7
Rated minimum efficacy values for high pressure sodium lamps with Ra ≤ 60’;
The title of Table 8 is replaced by the following:
‘Table 8
Rated minimum efficacy values for Metal Halide Lamps with Ra ≤ 80 and for high pressure sodium lamps with Ra > 60’
The second paragraph of Annex III.1.1.C is replaced by the following:
‘Fluorescent lamps without integrated ballast shall be able to operate with ballasts of energy efficiency class A2 or more efficient ballasts in accordance with point 2.2 of Annex III. In addition they may also operate with ballasts of less efficient classes than A2.’
Table 11 is replaced by the following:
Lamp lumen maintenance factors for single and double capped fluorescent lamps — Stage 2
Lamp lumen maintenance factor | Burning hours | |||
---|---|---|---|---|
Lamp types | 2 000 | 4 000 | 8 000 | 16 000 |
Double-Capped Fluorescent lamps operating on non-high frequency ballasts | 0,95 | 0,92 | 0,9 | — |
T8 Double-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,96 | 0,92 | 0,91 | 0,9 |
Other Double-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,95 | 0,92 | 0,9 | 0,9 |
Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) | 0,8 | 0,74 | — | — |
0,72 at 5 000 burning hours | ||||
Circular Single-Capped Fluorescent lamps operating on high frequency ballasts | 0,85 | 0,83 | 0,8 | — |
0,75 at 12 000 burning hours | ||||
Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts | 0,85 | 0,78 | 0,75 | — |
Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,9 | 0,84 | 0,81 | 0,78’ |
The following introductory phrase and Table 11a is added after Table 11:
‘The following cumulative deductions shall be applied to the values in Table 11:
Deduction percentages for fluorescent lamp lumen maintenance requirements
Lamp parameter | Deduction from lamp lumen maintenance requirement |
---|---|
Lamps with 95 ≥ Ra > 90 | At burning hours ≤ 8 000 h: – 5 % At burning hours > 8 000 h: – 10 % |
Lamps with Ra > 95 | At burning hours ≤ 4 000 h: – 10 % At burning hours > 4 000 h: – 15 % |
Lamps with a colour temperature ≥ 5 000 K | -10 %’ |
Table 12 is replaced by the following:
Lamp survival factors for single and double capped fluorescent lamps — Stage 2
Lamp survival factor | Burning hours | |||
---|---|---|---|---|
Lamp types | 2 000 | 4 000 | 8 000 | 16 000 |
Double-Capped Fluorescent lamps operating on non-high frequency ballasts | 0,99 | 0,97 | 0,9 | — |
Double-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,99 | 0,97 | 0,92 | 0,9 |
Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) | 0,98 | 0,77 | — | — |
0,50 at 5 000 burning hours | ||||
Circular Single-Capped Fluorescent lamps operating on high frequency ballasts | 0,99 | 0,97 | 0,85 | — |
0,50 at 12 000 burning hours | ||||
Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts | 0,98 | 0,9 | 0,5 | — |
Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,99 | 0,98 | 0,88 | —’ |
Table 13 is replaced by the following:
Lamp lumen maintenance factors and lamp survival factors for high pressure sodium lamps — Stage 2
High pressure sodium lamp category and burning hours for measurement | Lamp lumen maintenance factor | Lamp survival factor | |
---|---|---|---|
P ≤ 75 W LLMF and LSF measured at 12 000 burning hours | Ra ≤ 60 | > 0,80 | > 0,90 |
Ra > 60 | > 0,75 | > 0,75 | |
all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast | > 0,75 | > 0,80 | |
P > 75 W LLMF and LSF measured at 16 000 burning hours | Ra ≤ 60 | > 0,85 | > 0,90 |
Ra > 60 | > 0,70 | > 0,65 | |
all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast | > 0,75 | > 0,55 |
The requirements in Table 13 for retrofit lamps designed to operate on high pressure mercury vapour lamp ballast shall be applicable until 6 years after the entry into force of this Regulation.’;
Annex III.1.3(i) is replaced by the following:
Ambient temperature inside the luminaire at which the lamp was designed to maximise its luminous flux. If this temperature is equal to or lower than 0 °C or equal to or higher than 50 °C, it shall be stated that the lamp is not suitable for indoor use at standard room temperatures.’;
The following point (j) is added to point 1.3 of Annex III:
For fluorescent lamps without integrated ballast, the energy efficiency index(es) of ballasts as defined in Table 17 with which the lamp can operate.’;
Table 17 is replaced by the following:
Energy efficiency index requirements for non-dimmable ballasts for fluorescent lamps
LAMP DATA | BALLAST EFFICIENCY (Plamp/Pinput) | ||||||||
---|---|---|---|---|---|---|---|---|---|
Non-dimmable | |||||||||
Lamp type | Nominal Wattage | ILCOS CODE | Rated/typical wattage | A2 BAT | A2 | A3 | B1 | B2 | |
50 Hz | HF | ||||||||
W | W | W | |||||||
T8 | 15 | FD-15-E-G13-26/450 | 15 | 13,5 | 87,8 % | 84,4 % | 75,0 % | 67,9 % | 62,0 % |
T8 | 18 | FD-18-E-G13-26/600 | 18 | 16 | 87,7 % | 84,2 % | 76,2 % | 71,3 % | 65,8 % |
T8 | 30 | FD-30-E-G13-26/900 | 30 | 24 | 82,1 % | 77,4 % | 72,7 % | 79,2 % | 75,0 % |
T8 | 36 | FD-36-E-G13-26/1200 | 36 | 32 | 91,4 % | 88,9 % | 84,2 % | 83,4 % | 79,5 % |
T8 | 38 | FD-38-E-G13-26/1050 | 38,5 | 32 | 87,7 % | 84,2 % | 80,0 % | 84,1 % | 80,4 % |
T8 | 58 | FD-58-E-G13-26/1500 | 58 | 50 | 93,0 % | 90,9 % | 84,7 % | 86,1 % | 82,2 % |
T8 | 70 | FD-70-E-G13-26/1800 | 69,5 | 60 | 90,9 % | 88,2 % | 83,3 % | 86,3 % | 83,1 % |
TC-L | 18 | FSD-18-E-2G11 | 18 | 16 | 87,7 % | 84,2 % | 76,2 % | 71,3 % | 65,8 % |
TC-L | 24 | FSD-24-E-2G11 | 24 | 22 | 90,7 % | 88,0 % | 81,5 % | 76,0 % | 71,3 % |
TC-L | 36 | FSD-36-E-2G11 | 36 | 32 | 91,4 % | 88,9 % | 84,2 % | 83,4 % | 79,5 % |
TCF | 18 | FSS-18-E-2G10 | 18 | 16 | 87,7 % | 84,2 % | 76,2 % | 71,3 % | 65,8 % |
TCF | 24 | FSS-24-E-2G10 | 24 | 22 | 90,7 % | 88,0 % | 81,5 % | 76,0 % | 71,3 % |
TCF | 36 | FSS-36-E-2G10 | 36 | 32 | 91,4 % | 88,9 % | 84,2 % | 83,4 % | 79,5 % |
TC-D / DE | 10 | FSQ-10-E-G24q=1 FSQ-10-I-G24d=1 | 10 | 9,5 | 89,4 % | 86,4 % | 73,1 % | 67,9 % | 59,4 % |
TC-D / DE | 13 | FSQ-13-E-G24q=1 FSQ-13-I-G24d=1 | 13 | 12,5 | 91,7 % | 89,3 % | 78,1 % | 72,6 % | 65,0 % |
TC-D / DE | 18 | FSQ-18-E-G24q=2 FSQ-18-I-G24d=2 | 18 | 16,5 | 89,8 % | 86,8 % | 78,6 % | 71,3 % | 65,8 % |
TC-D / DE | 26 | FSQ-26-E-G24q=3 FSQ-26-I-G24d=3 | 26 | 24 | 91,4 % | 88,9 % | 82,8 % | 77,2 % | 72,6 % |
TC-T / TE | 13 | FSM-13-E-GX24q=1 FSM-13-I-GX24d=1 | 13 | 12,5 | 91,7 % | 89,3 % | 78,1 % | 72,6 % | 65,0 % |
TC-T / TE | 18 | FSM-18-E-GX24q=2 FSM-18-I-GX24d=2 | 18 | 16,5 | 89,8 % | 86,8 % | 78,6 % | 71,3 % | 65,8 % |
TC-T / TC-TE | 26 | FSM-26-E-GX24q=3 FSM-26-I-GX24d=3 | 26,5 | 24 | 91,4 % | 88,9 % | 82,8 % | 77,5 % | 73,0 % |
TC-DD / DDE | 10 | FSS-10-E-GR10q FSS-10-L/P/H-GR10q | 10,5 | 9,5 | 86,4 % | 82,6 % | 70,4 % | 68,8 % | 60,5 % |
TC-DD / DDE | 16 | FSS-16-E-GR10q FSS-16-I-GR8 FSS-16-L/P/H-GR10q | 16 | 15 | 87,0 % | 83,3 % | 75,0 % | 72,4 % | 66,1 % |
TC-DD / DDE | 21 | FSS-21-E-GR10q FSS-21-L/P/H-GR10q | 21 | 19,5 | 89,7 % | 86,7 % | 78,0 % | 73,9 % | 68,8 % |
TC-DD / DDE | 28 | FSS-28-E-GR10q FSS-28-I-GR8 FSS-28-L/P/H-GR10q | 28 | 24,5 | 89,1 % | 86,0 % | 80,3 % | 78,2 % | 73,9 % |
TC-DD / DDE | 38 | FSS-38-E-GR10q FSS-38-L/P/H-GR10q | 38,5 | 34,5 | 92,0 % | 89,6 % | 85,2 % | 84,1 % | 80,4 % |
TC | 5 | FSD-5-I-G23 FSD-5-E-2G7 | 5,4 | 5 | 72,7 % | 66,7 % | 58,8 % | 49,3 % | 41,4 % |
TC | 7 | FSD-7-I-G23 FSD-7-E-2G7 | 7,1 | 6,5 | 77,6 % | 72,2 % | 65,0 % | 55,7 % | 47,8 % |
TC | 9 | FSD-9-I-G23 FSD-9-E-2G7 | 8,7 | 8 | 78,0 % | 72,7 % | 66,7 % | 60,3 % | 52,6 % |
TC | 11 | FSD-11-I-G23 FSD-11-E-2G7 | 11,8 | 11 | 83,0 % | 78,6 % | 73,3 % | 66,7 % | 59,6 % |
T5 | 4 | FD-4-E-G5-16/150 | 4,5 | 3,6 | 64,9 % | 58,1 % | 50,0 % | 45,0 % | 37,2 % |
T5 | 6 | FD-6-E-G5-16/225 | 6 | 5,4 | 71,3 % | 65,1 % | 58,1 % | 51,8 % | 43,8 % |
T5 | 8 | FD-8-E-G5-16/300 | 7,1 | 7,5 | 69,9 % | 63,6 % | 58,6 % | 48,9 % | 42,7 % |
T5 | 13 | FD-13-E-G5-16/525 | 13 | 12,8 | 84,2 % | 80,0 % | 75,3 % | 72,6 % | 65,0 % |
T9-C | 22 | FSC-22-E-G10q-29/200 | 22 | 19 | 89,4 % | 86,4 % | 79,2 % | 74,6 % | 69,7 % |
T9-C | 32 | FSC-32-E-G10q-29/300 | 32 | 30 | 88,9 % | 85,7 % | 81,1 % | 80,0 % | 76,0 % |
T9-C | 40 | FSC-40-E-G10q-29/400 | 40 | 32 | 89,5 % | 86,5 % | 82,1 % | 82,6 % | 79,2 % |
T2 | 6 | FDH-6-L/P-W4,3x8,5d-7/220 | 5 | 72,7 % | 66,7 % | 58,8 % | |||
T2 | 8 | FDH-8-L/P-W4,3x8,5d-7/320 | 7,8 | 76,5 % | 70,9 % | 65,0 % | |||
T2 | 11 | FDH-11-L/P-W4,3x8,5d-7/420 | 10,8 | 81,8 % | 77,1 % | 72,0 % | |||
T2 | 13 | FDH-13-L/P-W4,3x8,5d-7/520 | 13,3 | 84,7 % | 80,6 % | 76,0 % | |||
T2 | 21 | FDH-21-L/P-W4,3x8,5d-7/ | 21 | 88,9 % | 85,7 % | 79,2 % | |||
T2 | 23 | FDH-23-L/P-W4,3x8,5d-7/ | 23 | 89,8 % | 86,8 % | 80,7 % | |||
T5-E | 14 | FDH-14-G5-L/P-16/550 | 13,7 | 84,7 % | 80,6 % | 72,1 % | |||
T5-E | 21 | FDH-21-G5-L/P-16/850 | 20,7 | 89,3 % | 86,3 % | 79,6 % | |||
T5-E | 24 | FDH-24-G5-L/P-16/550 | 22,5 | 89,6 % | 86,5 % | 80,4 % | |||
T5-E | 28 | FDH-28-G5-L/P-16/1150 | 27,8 | 89,8 % | 86,9 % | 81,8 % | |||
T5-E | 35 | FDH-35-G5-L/P-16/1450 | 34,7 | 91,5 % | 89,0 % | 82,6 % | |||
T5-E | 39 | FDH-39-G5-L/P-16/850 | 38 | 91,0 % | 88,4 % | 82,6 % | |||
T5-E | 49 | FDH-49-G5-L/P-16/1450 | 49,3 | 91,6 % | 89,2 % | 84,6 % | |||
T5-E | 54 | FDH-54-G5-L/P-16/1150 | 53,8 | 92,0 % | 89,7 % | 85,4 % | |||
T5-E | 80 | FDH-80-G5-L/P-16/1150 | 80 | 93,0 % | 90,9 % | 87,0 % | |||
T5-E | 95 | FDH-95-G5-L/P-16/1150 | 95 | 92,7 % | 90,5 % | 84,1 % | |||
T5-E | 120 | FDH-120-G5-L/P-16/1450 | 120 | 92,5 % | 90,2 % | 84,5 % | |||
T5-C | 22 | FSCH-22-L/P-2GX13-16/225 | 22,3 | 88,1 % | 84,8 % | 78,8 % | |||
T5-C | 40 | FSCH-40-L/P-2GX13-16/300 | 39,9 | 91,4 % | 88,9 % | 83,3 % | |||
T5-C | 55 | FSCH-55-L/P-2GX13-16/300 | 55 | 92,4 % | 90,2 % | 84,6 % | |||
T5-C | 60 | FSCH-60-L/P-2GX13-16/375 | 60 | 93,0 % | 90,9 % | 85,7 % | |||
TC-LE | 40 | FSDH-40-L/P-2G11 | 40 | 91,4 % | 88,9 % | 83,3 % | |||
TC-LE | 55 | FSDH-55-L/P-2G11 | 55 | 92,4 % | 90,2 % | 84,6 % | |||
TC-LE | 80 | FSDH-80-L/P-2G11 | 80 | 93,0 % | 90,9 % | 87,0 % | |||
TC-TE | 32 | FSMH-32-L/P-2GX24q=3 | 32 | 91,4 % | 88,9 % | 82,1 % | |||
TC-TE | 42 | FSMH-42-L/P-2GX24q=4 | 43 | 93,5 % | 91,5 % | 86,0 % | |||
TC-TE | 57 | FSM6H-57-L/P-2GX24q=5 FSM8H-57-L/P-2GX24q=5 | 56 | 91,4 % | 88,9 % | 83,6 % | |||
TC-TE | 70 | FSM6H-70-L/P-2GX24q=6 FSM8H-70-L/P-2GX24q=6 | 70 | 93,0 % | 90,9 % | 85,4 % | |||
TC-TE | 60 | FSM6H-60-L/P-2G8=1 | 63 | 92,3 % | 90,0 % | 84,0 % | |||
TC-TE | 62 | FSM8H-62-L/P-2G8=2 | 62 | 92,2 % | 89,9 % | 83,8 % | |||
TC-TE | 82 | FSM8H-82-L/P-2G8=2 | 82 | 92,4 % | 90,1 % | 83,7 % | |||
TC-TE | 85 | FSM6H-85-L/P-2G8=1 | 87 | 92,8 % | 90,6 % | 84,5 % | |||
TC-TE | 120 | FSM6H-120-L/P-2G8=1 FSM8H-120-L/P-2G8=1 | 122 | 92,6 % | 90,4 % | 84,7 % | |||
TC-DD | 55 | FSSH-55-L/P-GRY10q3 | 55 | 92,4 % | 90,2 % | 84,6 %’ |
The following paragraph is added after the first paragraph of Annex IV:
‘Member States authorities shall use reliable, accurate and reproducible measurement procedures, which take into account the generally recognised state of the art measurement methods, including methods set out in documents the reference numbers of which have been published for that purpose in the Official Journal of the European Union.’
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As adopted by EU): The original version of the legislation as it stood when it was first adopted in the EU. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: