- Latest available (Revised)
- Original (As made)
There are currently no known outstanding effects for the The Pyrotechnic Articles (Safety) Regulations 2015, Paragraph 1.
Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.
1.—(1) Each pyrotechnic article must attain the performance characteristics specified by the manufacturer to the [F1approved] body in order to ensure maximum safety and reliability.E+W+S
(2) Each pyrotechnic article must be designed and manufactured in such a way that it can be disposed of safely by a suitable process with minimum effect on the environment.
(3) Each pyrotechnic article must function correctly when used for its intended purpose.
(4) Each pyrotechnic article must be tested under realistic conditions.
(5) If it is not possible to meet the requirement in sub-paragraph (4) in a laboratory, the tests must be carried out in the conditions in which the pyrotechnic article is to be used.
(6) The following information and properties, where applicable, must be considered or tested—
(a)design, construction and characteristic properties, including detailed chemical composition (mass and percentage of substances used) and dimensions;
(b)the physical and chemical stability of the pyrotechnic article in all normal, foreseeable environmental conditions;
(c)sensitivity to normal, foreseeable handling and transportation;
(d)compatibility of all components as regards their chemical stability;
(e)resistance of the pyrotechnic article to moisture where it is intended to be used in humid or wet conditions and where its safety or reliability may be adversely affected by moisture;
(f)resistance to low and high temperatures, where the article is intended to be kept or used at such temperatures and its safety or reliability may be adversely affected by cooling or heating of a component or of the pyrotechnic articles as a whole;
(g)safety features intended to prevent untimely or inadvertent initiation or ignition;
(h)suitable instructions and, where necessary, markings in respect of safe handling, storage, use (including safety distances) and disposal;
(i)the ability of the pyrotechnic article, its wrapping or other components to withstand deterioration under normal, foreseeable storage conditions;
(j)specification of all devices and accessories needed and operating instructions for safe functioning of the pyrotechnic article.
(7) During transportation and normal handling, unless specified by the manufacturer's instructions, the pyrotechnic article must contain the pyrotechnic composition.
(8) Pyrotechnic articles must not contain detonative explosives other than black powder and flash composition, except for pyrotechnic articles of categories P1, P2, T2 and fireworks of category F4 meeting the following conditions—
(a)the detonative explosive cannot be easily extracted from the pyrotechnic article;
(b)for category P1, the pyrotechnic article cannot function in a detonative manner, or cannot, as designed and manufactured, initiate secondary explosives;
(c)for categories F4, T2 and P2, the pyrotechnic article is designed and intended not to function in a detonative manner, or if designed to detonate, it cannot as designed and manufactured initiate secondary explosives.
(9) The various groups of pyrotechnic articles must at least also comply with the following requirements.
Extent Information
E1This version of this provision extends to England and Wales and Scotland only; a separate version has been created for Northern Ireland only
Textual Amendments
F1Word in Sch. 2 para. 1(1) substituted (E.W.S.) (31.12.2020) by The Product Safety and Metrology etc. (Amendment etc.) (EU Exit) Regulations 2019 (S.I. 2019/696), reg. 1, Sch. 19 para. 38 (with Sch. 19 para. 36) (as amended by S.I. 2020/676, regs. 1(1), 2); 2020 c. 1, Sch. 5 para. 1(1)
1.—(1) Each pyrotechnic article must attain the performance characteristics specified by the manufacturer to the notified body in order to ensure maximum safety and reliability.N.I.
(2) Each pyrotechnic article must be designed and manufactured in such a way that it can be disposed of safely by a suitable process with minimum effect on the environment.
(3) Each pyrotechnic article must function correctly when used for its intended purpose.
(4) Each pyrotechnic article must be tested under realistic conditions.
(5) If it is not possible to meet the requirement in sub-paragraph (4) in a laboratory, the tests must be carried out in the conditions in which the pyrotechnic article is to be used.
(6) The following information and properties, where applicable, must be considered or tested—
(a)design, construction and characteristic properties, including detailed chemical composition (mass and percentage of substances used) and dimensions;
(b)the physical and chemical stability of the pyrotechnic article in all normal, foreseeable environmental conditions;
(c)sensitivity to normal, foreseeable handling and transportation;
(d)compatibility of all components as regards their chemical stability;
(e)resistance of the pyrotechnic article to moisture where it is intended to be used in humid or wet conditions and where its safety or reliability may be adversely affected by moisture;
(f)resistance to low and high temperatures, where the article is intended to be kept or used at such temperatures and its safety or reliability may be adversely affected by cooling or heating of a component or of the pyrotechnic articles as a whole;
(g)safety features intended to prevent untimely or inadvertent initiation or ignition;
(h)suitable instructions and, where necessary, markings in respect of safe handling, storage, use (including safety distances) and disposal;
(i)the ability of the pyrotechnic article, its wrapping or other components to withstand deterioration under normal, foreseeable storage conditions;
(j)specification of all devices and accessories needed and operating instructions for safe functioning of the pyrotechnic article.
(7) During transportation and normal handling, unless specified by the manufacturer's instructions, the pyrotechnic article must contain the pyrotechnic composition.
(8) Pyrotechnic articles must not contain detonative explosives other than black powder and flash composition, except for pyrotechnic articles of categories P1, P2, T2 and fireworks of category F4 meeting the following conditions—
(a)the detonative explosive cannot be easily extracted from the pyrotechnic article;
(b)for category P1, the pyrotechnic article cannot function in a detonative manner, or cannot, as designed and manufactured, initiate secondary explosives;
(c)for categories F4, T2 and P2, the pyrotechnic article is designed and intended not to function in a detonative manner, or if designed to detonate, it cannot as designed and manufactured initiate secondary explosives.
(9) The various groups of pyrotechnic articles must at least also comply with the following requirements.
Extent Information
E2This version of this provision extends to Northern Ireland only; a separate version has been created for England and Wales and Scotland only
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download.
Would you like to continue?
The Whole Instrument you have selected contains over 200 provisions and might take some time to download. You may also experience some issues with your browser, such as an alert box that a script is taking a long time to run.
Would you like to continue?
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.
Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Impact Assessments generally accompany all UK Government interventions of a regulatory nature that affect the private sector, civil society organisations and public services. They apply regardless of whether the regulation originates from a domestic or international source and can accompany primary (Acts etc) and secondary legislation (SIs). An Impact Assessment allows those with an interest in the policy area to understand:
This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: