The following data-quality objectives for the required accuracy of assessment methods, of minimum time coverage and of data capture of measurement are laid down to guide quality-assurance programmes.
Sulphur dioxide, nitrogen dioxide and oxides of nitrogen | Particulate matter and lead | |
---|---|---|
Continuous measurement | ||
Accuracy | 15% | 25% |
Minimum data capture | 90% | 90% |
Indicative measurement | ||
Accuracy | 25% | 50% |
Minimum data capture | 90% | 90% |
Minimum time coverage | 14% (One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year) | 14% (One measurement a week at random, evenly distributed over the year, or eight weeks evenly distributed over the year) |
Modelling Accuracy: | ||
Hourly averages | 50%–60% | |
Daily averages | 50% | |
Annual averages | 30% | 50% |
Objective estimation | ||
Accuracy: | 75% | 100% |
The accuracy of the measurement is defined as laid down in the “Guide to the Expression of Uncertainty of Measurements” (ISO 1993)(1) or in ISO 5725-1 “Accuracy (trueness and precision) of measurement methods and results” (ISO 1994)(2). The percentages in the table are given for individual measurements averaged, over the period considered, by the limit value, for a 95% confidence interval (bias + two times the standard deviation). The accuracy for continuous measurements should be interpreted as being applicable in the region of the appropriate limit value.
The accuracy for modelling and objective estimation is defined as the maximum deviation of the measured and calculated concentration levels, over the period considered by the limit value, without taking account of the timing of the events.
The requirements for minimum data capture and time coverage do not include losses of data due to the regular calibration or the normal maintenance of the instrumentation.
The Department may allow for random measurements to be made instead of continuous measurements for particulate matter and lead by methods for which accuracy within the 95% confidence interval with respect to continuous monitoring has been demonstrated to be within 10%. Random sampling must be spread evenly over the year.
Copies of these International Standards Organisation publications can be purchased from the British Standards Institution “BSI” sales department either by telephone on 020-8996-9001 or by post from the BSI, Standards House, 389 Chiswick High Road, London W4 4AL
Copies of these International Standards Organisation publications can be purchased from the British Standards Institution “BSI” sales department either by telephone on 020-8996-9001 or by post from the BSI, Standards House, 389 Chiswick High Road, London W4 4AL
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: