Search Legislation

The Weighing Equipment (Automatic Catchweighing Instruments) Regulations (Northern Ireland) 2006

Status:

This is the original version (as it was originally made).

Regulation 5(b)

SCHEDULE 3(Requirements in respect of Use and Manner of Use)

Maximum and minimum capacities (Extract from Clause 2.4 of OIML R51)

Maximum capacity (Max) and minimum capacity (Min) shall be specified by the manufacturer.

The minimum capacity shall not be less than:

for class Y(a):20 e
for class Y(b):10 e
for postal scales:5 e

Temperature (Principle from Clause 2.9.1 of OIML R51)

Instruments shall comply with the appropriate metrological and technical requirements at temperatures from –10°C to +40°C. However, for special applications the limits of the temperature range may differ from those given above but such a range shall not be less than 30°C and shall be specified in the descriptive markings.

Where an automatic catchweighing instrument is marked with a temperature range it shall not be used for trade in temperatures outside that range.

Tilting (Principle from Clause 2.9.3 of OIML R51)

Instruments which are not intended for installation in a fixed position and which do not have a level indicator shall comply with the appropriate metrological and technical requirements when tilted by 5%.

Where an automatic catchweighing instrument is fitted with a level indicating device it shall enable the instrument to be set to a tilt of 1% or less.

Specified purpose or manner of use

Where an automatic catchweighing instrument is marked (in accordance with Schedule 4) with a mark which signifies the purpose or manner of use, it shall not be used for a purpose or in a manner which does not accord with that marking.

Instruments of Class Y(b) shall only be used for weighing ballast or waste or other goods in accordance with the particulars of the approved pattern.

Definition of waste

For the purposes of the second paragraph of the preceding section of this Schedule (Specified purpose or manner of use), “waste” shall be construed in accordance with Article 2(2) of the Waste and Contaminated Land (Northern Ireland) Order 1997(1), provided that “waste” shall include any waste disposed of for reprocessing or recycling purposes but shall not include any radioactive waste as defined in section 2 of the Radioactive Substances Act 1993(2).

Zero-setting device (Extract from Clause 3.3.1 of OIML R51)

An automatic zero-setting device shall operate:

  • only when the stability criteria are fulfilled

  • sufficiently often to ensure that the zero is maintained within 0.5 e.

A non-automatic zero-setting device shall not be operable during automatic operation.

A semi-automatic zero-setting device shall function only when the stability criteria are fulfilled.

Zero-tracking device (Extract from Clause 3.3.2 of OIML R51)

A zero-tracking device shall operate only when:

  • the indication is at zero, or at a negative net value equivalent to gross zero, and

  • the stability criteria are fulfilled, and

  • the corrections are not more than 0.5 e/second.

Tare device (Extract from Clause 3.3.3 of OIML R51)

A semi-automatic or automatic tare device shall operate only when the stability criteria are fulfilled.

A non-automatic or semi-automatic tare device shall not be operable during automatic operation.

Suitability for use (Extract from Clause 3.1 of OIML R51)

An instrument shall be designed to suit the method of operation and the loads for which it is intended. It shall be of adequately robust construction in order that it maintains its metrological characteristics.

Minimum capacity (Extract from Clause 3.5 of OIML R51)

Printing a weighing result below minimum capacity shall not be possible.

Maximum capacity (Extract from Clause 3.4.3 of OIML R51)

There shall be no indication above Max + 9 e.

Rate of operation

An automatic catchweighing instrument shall not be used above the maximum rate of operation.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

More Resources

Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as made version that was used for the print copy
  • correction slips

Click 'View More' or select 'More Resources' tab for additional information including:

  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • links to related legislation and further information resources