5.—(1) For the purposes of section 49(1) of the Act (approval of measuring devices), subject to paragraph (2), sound level meters which:
(a)comply with the requirements of Class 1 of BS EN 61672; and
(b)are capable of determining the A-weighted sound pressure level using time-weighting ‘F’,
are devices approved for the measurement of the underlying level of noise, when used in accordance with the requirements of regulations 7 and 8.
(2) Where LAN,T measurements are used to determine the underlying level of noise, the devices specified in paragraph (1) must in addition:
(a)sample the sound pressure level at a rate of not less than 10 times per second; and
(b)use in the statistical calculation a class interval of no greater than 0.5 decibels.
(3) When time weighting ‘F’ is used for the purposes of paragraph (1) it shall not exceed 0.6 seconds in a period of no shorter than one minute and no longer than 5 minutes.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: