Search Legislation

The Measuring Equipment (Capacity Measures and Testing Equipment) Regulations 1995

 Help about what version

What Version

 Help about advanced features

Advanced Features

More Resources

Changes over time for: The Measuring Equipment (Capacity Measures and Testing Equipment) Regulations 1995

 Help about opening options

Status:

Point in time view as at 31/12/2020.

Changes to legislation:

There are currently no known outstanding effects for the The Measuring Equipment (Capacity Measures and Testing Equipment) Regulations 1995. Help about Changes to Legislation

Close

Changes to Legislation

Revised legislation carried on this site may not be fully up to date. At the current time any known changes or effects made by subsequent legislation have been applied to the text of the legislation you are viewing by the editorial team. Please see ‘Frequently Asked Questions’ for details regarding the timescales for which new effects are identified and recorded on this site.

Statutory Instruments

1995 No. 735

WEIGHTS AND MEASURES

The Measuring Equipment (Capacity Measures and Testing Equipment) Regulations 1995

Made

10th March 1995

Laid before Parliament

14th March 1995

Coming into force

10th April 1995

The Secretary of State, in exercise of his powers under sections 5(9), 10(1)(b), 11(1), (4) and (7), 15(1) and (2), 86(1) and 94(1) of the Weights and Measures Act 1985(1) and of all other powers enabling him in that behalf, hereby makes the following Regulations:—

PART IE+W+SGENERAL

Citation, commencement, revocation and savingE+W+S

1.—(1) These Regulations may be cited as the Measuring Equipment (Capacity Measures and Testing Equipment) Regulations 1995 and shall come into force on 10th April 1995.

(2) The Regulations specified in the first column of Schedule 1 to these Regulations are hereby revoked to the extent specified in the third column of that Schedule save in relation to capacity measures passed as fit for use for trade and stamped before these Regulations come into force; and accordingly, these Regulations shall not apply to those measures.

Commencement Information

I1Reg. 1 in force at 10.4.1995, see reg. 1(1)

InterpretationE+W+S

2.—(1) In these Regulations—

“the Act” means the Weights and Measures Act 1985;

“BS 604: 1982” means the British Standard specification for graduated glass measuring cylinders(2);

“BS 1922: 1987” means the British Standard specification for glass dispensing measures for pharmaceutical purposes(3);

“BS 6001: Part 1: 1991” means the British Standard specification for sampling procedures for inspection by attributes(4);

“BS 6002: Part 1: 1993” means the British Standard Specification for single sampling plans indexed by acceptable quality level (AQL) for lot-by-lot inspection(5);

“BS 6696: 1986” means the British Standard methods for use and testing of volumetric glassware(6);

“digital” means capable of assigning only certain discrete values or positions within a continuous range by a series of discontinuous steps;

“discrimination threshold” means, in the case of weighing equipment with a digital indicator, the weight which produces a change of reading of one digit, and in the case of weighing equipment with an analogue indicator, the weight which produces a one millimetre movement of the pointer; and in this definition, “analogue” means capable of assigning any value or position within a continuous range;

“double measure” means a measure comprising two parts, each part being a capacity measure;

“EEA State” means a State which is a Contracting Party to the EEA Agreement F1... but until the EEA Agreement comes into force in relation to Liechtenstein does not include the State of Liechtenstein; and “the EEA Agreement” means the Agreement on the European Economic Area signed at Oporto on 2nd May 1992 as adjusted by the Protocol signed at Brussels on 17th March 1993;

“graduated measure” means a measure with more than four scale marks or, in the case of a measure which is both a metric and imperial measure, in each of metric and imperial units;

“the prescribed limits of error” shall be construed in accordance with regulation 15;

“the stamp” means the prescribed stamp(7);

“sub-divided measure” means a measure with four or fewer scale marks or, in the case of a measure which is both a metric and imperial measure, in each of metric and imperial units; and

“suitable weighing machine” means a weighing machine, which complies with the requirements of the Weights and Measures (Local and Working Standard Weights and Testing Equipment) Regulations 1986(8), having a discrimination threshold and a repeatability in grams not exceeding one-fifth of the appropriate limit of error expressed in millimetres relating to the standard, equipment or measure it is used to test.

(2) The abbreviations of, and symbols for, units of measurement used in these Regulations refer to the relevant units as follows—

gallongal
quartqt
pintpt
fluid ouncefl oz
litrel or L
centilitrecl or cL
millilitreml
degree Celsius°C.

Textual Amendments

Commencement Information

I2Reg. 2 in force at 10.4.1995, see reg. 1(1)

Application of RegulationsE+W+S

3.—(1) These Regulations apply to liquid capacity measures and dry capacity measures for use for trade, other than—

(a)liquid capacity measures to which the Capacity Serving Measures (Intoxicating Liquor) Regulations 1988(9) apply;

(b)liquid capacity measures specified in paragraph 4 of Schedule 4 to the Weights and Measures (Packaged Goods) Regulations 1986(10) for use only for making up or checking packages in accordance with section 49(2)(a) of the Act;

(c)liquid capacity measures for use for measuring liquid lubricants;

(d)liquid capacity measures for use for measuring milk;

(e)dry capacity measures for use for measuring peas and beans;

(f)capacity measures which exceed—

(i)20 litres for metric measures, or

(ii)before 1st October 1995, 5 gallons, and on and after that date 16 pints, for imperial measures; or

[F2(g)capacity measures being containers which—

(i)have been supplied by retail containing a cosmetic product;

(ii)are provided by an individual to a retailer; and

(iii)are used by the retailer in the presence of the individual in ascertaining or determining the amount by volume of a cosmetic product which is of the same description as that mentioned in (i) above and is to be supplied to him in the container,

and in this sub-paragraph “cosmetic product” means any substance or preparation intended to be placed in contact with the various external parts of the human body (that is to say, the epidermis, hair system, nails, lips and external genital organs) or with the teeth and the mucous membranes of the oral cavity with a view exclusively or mainly to cleaning them, perfuming them, changing their appearance, correcting bodily odours, protecting them or keeping them in good condition.]

(2) Regulations 4, 5, 6(1)(a) to (d), 7, 9, 10, 12 and [F316(4)] and (5)(a) below do not apply to dispensing measures for pharmaceutical purposes.

(3) Capacity measures to which these Regulations apply are hereby prescribed for the purposes of section 11(1) of the Act.

(4) Graduated and sub-divided capacity measures referred to in regulation [F4regulation 16(5)(c)] below are hereby prescribed as being lawful for use for trade for the purposes of section 10(1)(b) of the Act.

PART IIE+W+SMATERIALS, PRINCIPLES OF CONSTRUCTION AND USE

Categories of capacity measuresE+W+S

4.  For the purposes of these Regulations, a capacity measure is either—

(a)a line measure marked with lines which—

(i)are conspicuous and durable, and

(ii)are marked on the outside surface of a measure which is made of transparent or translucent material and on the inside surface of a measure which is made of opaque material; or

(b)a brim measure having a brim in a horizontal plane when the measure is on a flat, horizontal surface.

Commencement Information

I4Reg. 4 in force at 10.4.1995, see reg. 1(1)

Materials and principles of construction of capacity measuresE+W+S

5.  Capacity measures shall be made of any of the following materials—

(a)aluminium alloy;

(b)enamelled metal;

(c)glass;

(d)plated, tinned, galvanized or stainless steel;

(e)plastic material which resists deformation under hand pressure and does not split or show signs of striation after immersion in water at 95 °C for 10 minutes;

(f)silver or silver alloy; or

(g)any other material which is rigid, stable and sufficiently durable for normal use for trade.

Commencement Information

I5Reg. 5 in force at 10.4.1995, see reg. 1(1)

Construction of capacity measuresE+W+S

6.—(1) Every capacity measure shall be so constructed that—

(a)it does not rock when its base is on a flat, horizontal surface;

(b)its brim and lines are horizontal when its base is on a flat, horizontal surface;

(c)it remains reasonably perpendicular when rotated about its vertical axis;

(d)no air is trapped on filling; and

(e)no liquid or solid is trapped on emptying when tilted so that its vertical axis is at an angle of 135 degrees from the vertical for any rotational orientation about that axis.

(2) Save where paragraph (4) has effect, dispensing measures for pharmaceutical purposes shall comply with the requirements of BS 604: 1982 or BS 1922: 1987.

(3) In the case of a double measure—

(a)the measure shall be so constructed that it is readily identifiable as a double measure;

(b)the part of the measure having the greater capacity shall have a purported value which is twice that of the part having the lesser capacity; and

(c)neither part of the measure shall be a graduated measure or a sub-divided measure.

(4) Any capacity measure, instead of complying with the requirements of paragraph (1) or (2) above, as the case may be, may comply with—

(a)a relevant national standard or code of practice issued by a national standards body or similar body in a member State or an EEA State;

(b)a relevant international standard officially recognised for use in a member State or an EEA State;

(c)a relevant technical provision of mandatory application in relation to marketing or use in a member State or an EEA State; or

(d)descriptive technical documents relating to manufacturing processes lawfully carried out in a member State or an EEA State, being documents which are sufficiently detailed to enable the measures to be evaluated (if necessary by the carrying out of tests) as capacity measures for use otherwise than as dispensing measures for pharmaceutical purposes or as such dispensing measures, as may be appropriate,

being requirements which, in any case, afford in use at least equivalent standards of safety, suitability and fitness for purpose of such measures as does paragraph (1) above and, in the case of dispensing measures for pharmaceutical purposes, BS 604: 1982 or BS 1922: 1987.

(5) In paragraph (4)(d) above references to descriptive technical documents are references to such documents which are either published and available to members of the public or are made available by the manufacturer on request—

(a)to any person who is a user or potential user of the capacity measures in question; and

(b)to an inspector for the purposes of the performance by him of his functions under the Act or these Regulations relating to inspection, testing, passing as fit for use for trade and stamping of a capacity measure.

Commencement Information

I6Reg. 6 in force at 10.4.1995, see reg. 1(1)

Purpose and manner of use of capacity measuresE+W+S

7.  No person shall use a capacity measure—

(a)for the measurement of goods which might affect, or be affected by, the material from which the measure is made,

(b)in such a manner that it is exposed to conditions which adversely affects its accuracy or function, or

(c)for the measurement of intoxicating liquor before its transfer to a container in which the buyer is to receive it, unless the buyer has a clear and unobstructed view of the measurement and transfer.

Commencement Information

I7Reg. 7 in force at 10.4.1995, see reg. 1(1)

PART IIIE+W+STESTING

Capacity measures for testing to be cleanE+W+S

8.  Every capacity measure submitted for testing shall be in a clean condition.

Commencement Information

I8Reg. 8 in force at 10.4.1995, see reg. 1(1)

Method of testing of capacity measuresE+W+S

9.  Subject to regulation 12 below, the inspector shall test every capacity measure—

(a)by trial for use in the manner in which it is to be used as a measure, either for holding or for delivering its contents;

(b)by using—

(i)where practicable, water or an intended liquid of use, or

(ii)in the case of a dry capacity measure where the use of a liquid is impracticable, seeds, glass beads or polystyrene beads of an appropriate and regular size, proper precautions being taken to achieve reliable and consistent results; and

(c)subject in the case of dispensing measures for pharmaceutical purposes to regulation 11 below, either—

(i)volumetrically, by comparison with one or more local or working standards or by means of appropriate testing equipment which complies with the requirements of the Weights and Measures (Local and Working Standard Capacity Measures and Testing Equipment) Regulations 1990(11); or

(ii)gravimetrically, by determining the weight of water of known density using a suitable weighing machine.

Commencement Information

I9Reg. 9 in force at 10.4.1995, see reg. 1(1)

Testing of nominal capacity and scale marks of capacity measuresE+W+S

10.—(1) The inspector shall test the nominal capacity and all the scale marks or, in the case of a graduated measure, such of them as he considers necessary.

(2) The capacity of a measure shall be the volume at 20 °C when the measure is on a horizontal surface and—

(a)in the case of a line measure, the bottom part of the meniscus coincides with the top of the line, or

(b)in the case of a brim measure, the surface of the liquid is in the same plane as the brim.

Commencement Information

I10Reg. 10 in force at 10.4.1995, see reg. 1(1)

Testing of dispensing measures for pharmaceutical purposesE+W+S

11.  [F5The inspector] shall test every dispensing measure for pharmaceutical purposes either—

(a)in accordance with the requirements of BS 6696: 1986, using a suitable weighing machine; or

(b)volumetrically—

(i)by comparison with one or more local standards (other than a brim measure made of metal), or

(ii)by means of a peristaltic pump dispenser which complies with the requirements of the Weights and Measures (Local and Working Standard Capacity Measures and Testing Equipment) Regulations 1990.

Textual Amendments

Commencement Information

I11Reg. 11 in force at 10.4.1995, see reg. 1(1)

Testing of groups of capacity measuresE+W+S

12.—(1) Where—

(a)a group of capacity measures [F6of] the same nominal capacity and the same manufacture is submitted for testing; and

(b)the conditions specified in paragraph (2) below are satisfied with respect to the group,

the inspector may, at the request of the person submitting them (“the submitter”), confine the testing to a number of measures determined and selected as specified in paragraph (3) below.

(2) The conditions referred to in paragraph (1)(b) above are that—

(a)the group shall be clearly identifiable and shall comprise more than 500 but not more than 150,000 measures;

(b)the measures in the group shall all have been produced by the same production process; and

(c)the group shall be accompanied by records of the production process and of any subsequent action taken by the manufacturer which are adequate to show that the measures in the group are likely to fall within the prescribed limits of error.

(3) The number of measures referred to in paragraph (1) above shall be determined, and the measures shall be selected, by sampling plans and procedures using samples which the inspector considers to be representative; and the sample of measures shall be tested, in accordance either with paragraph (4) below or, if the submitter so requests, with paragraph (5) below.

(4) Under this paragraph the sample of measures—

(a)shall be selected F7... in accordance with BS 6001: Part 1: 1991; and

(b)shall be tested for all the appropriate requirements of these Regulations, including limits of error on capacity conducted either volumetrically or gravimetrically as described in regulation 9(c) above and in accordance with BS 6002: 1993.

(5) Under this paragraph the sample of measures shall be selected in accordance with BS 6001: Part 1: 1991 and—

(a)the sample shall be tested for all the appropriate requirements of these Regulations except limits of error on capacity; and

(b)a sub-sample of the measures selected under paragraph (3) above which the inspector considers to be representative, shall be tested gravimetrically as described in regulation 9(c) above and in accordance with BS 6002: 1993.

(6) Under each of paragraphs (4) and (5) above, the test shall provide an acceptable quality level equal to 1 per cent.

(7) If the sample selected as specified in paragraph (3) above satisfies the test specified in paragraph (4) above or both the tests specified in paragraph (5) above, the other measures in the group shall be treated as having satisfied the test or tests as the case may be.

Textual Amendments

Commencement Information

I12Reg. 12 in force at 10.4.1995, see reg. 1(1)

Capacity measures imported from [F8a member State] or EEA StateE+W+S

13.—(1) In relation to capacity measures imported into Great Britain from [F9a member State] or an EEA State, subject to paragraph (4) below, an inspector shall not carry out any test in accordance with the provisions of regulations 8 to 12 above if, together with the measures being imported, he is presented with the requisite documentation.

(2) In this regulation and in regulation 16 below “requisite documentation” means—

(a)the test report of an approved body that the capacity measures which are the subject of that report have been tested on the same basis as those set out in regulations 8 to 12 above and stating which tests have been applied to them; and

(b)the test results relating to those tests.

[F10(3) A body is an “approved body” for the purposes of this regulation if it is a body in a member State or in an EEA State which has responsibility in that State for metrological control of capacity measures or is a laboratory which has been accredited for the purposes of testing capacity measures in a member State or in an EEA State as being a body which conforms with the criteria set out in BS EN ISO/IEC 17025:2000.]

(4) Nothing in these Regulations shall prevent an inspector testing in accordance with regulations 8 to 12 above where he is not satisfied—

(a)that the test report or the results presented to him are authentic; or

(b)that the test results presented to him are results which in fact relate to the capacity measures being imported.

Provision of material for inspector’s useE+W+S

14.  For the purposes of the performance by an inspector of his functions under the Act or these Regulations relating to inspection, testing, passing as fit for use for trade and stamping of any capacity measure, a person submitting such a measure to an inspector or who an inspector has reasonable cause to believe has possession of such a measure for use for trade shall, if requested, provide for the inspector’s use such material as the inspector may reasonably require, and any material so provided shall be returned to the person in question.

Commencement Information

I14Reg. 14 in force at 10.4.1995, see reg. 1(1)

PART IVE+W+SSUPPLEMENTARY PROVISIONS

Prescribed limits of errorE+W+S

15.  The prescribed limits of error—

(a)for dispensing measures for pharmaceutical purposes, shall be those set out in BS 604: 1982 or BS 1922: 1987, as appropriate, and

(b)for all other capacity measures shall,—

(i)in the case of line measures, be the amounts set out in column 3 of Schedule 2 to these Regulations in excess and in deficiency, and

(ii)in the case of brim measures, be the amounts set out in column 4 of that Schedule in excess only.

Commencement Information

I15Reg. 15 in force at 10.4.1995, see reg. 1(1)

Passing as fit for use for trade and stampingE+W+S

16.—(1) Save in the case of capacity measures imported from [F11a member State] or an EEA State, no capacity measure shall be passed as fit for use for trade unless—

(a)on testing,—

(i)it falls within the prescribed limits of error;

(ii)an inspector is of the opinion that it is not constructed in a manner which facilitates fraudulent use and that it does not bear any decorations or designs which might cause confusion in use; and

(iii)it complies with all the appropriate requirements of these Regulations; or

(b)in the case of a measure which has not been tested, it forms part of a group of measures treated under regulation 12(7) above as having satisfied the test or tests therein mentioned.

(2) In the case of capacity measures imported from [F12a member State] or an EEA State, no capacity measure shall be passed as fit for use for trade unless—

(a)either—

(i)where the requisite documentation is presented in accordance with regulation 13 above, the test report recites and the test data confirm to the satisfaction of the inspector that on testing in accordance with provisions of the law of a member State or EEA State it fell within limits of error which afford in use at least an equivalent standard to the prescribed limits of error and, in the case of dispensing measures for pharmaceutical purposes, BS 604: 1982 or BS 1922: 1987; or

(ii)in the case of a measure which has not been tested, it formed part of a group of measures treated under provisions of the law of a member State or EEA State corresponding to regulation 12(7) above as having satisfied a relevant test or tests; or

(iii)it complies with all the relevant requirements of these Regulations; and

(b)the inspector is of the opinion that it is not constructed in a manner which facilitates fraudulent use and that it does not bear any decorations or designs which might cause confusion in use.

(3) No measure (not being a single measure) shall be passed as fit for use for trade unless it is a double measure.

(4) Where practicable, the stamp shall be placed on the outside of the measure, adjacent to the marking of the amount of nominal capacity, but in any other case shall be applied to a metal plate permanently attached to the measure.

(5) No capacity measure shall be stamped unless—

(a)its nominal capacity is marked on its outside surface and is so marked conspicuously, legibly and durably—

(i)on the body of the measure adjacent to the brim or to the line denoting the nominal capacity or, in the case of a measure without scale marks, at approximately mid-height, or

(ii)on a shield or plate permanently attached to the outside of the measure,

and not on any handle, rim, edge or stem;

(b)in the case of a line measure, its nominal capacity is denoted by a line (which shall, in the case of a measure made of opaque material, be marked on the inside surface);

(c)the scale marks are marked on the measure in the same field of view as the mark of the nominal capacity, and

(i)in the case of a graduated measure, are numbered at appropriate intervals, and

(ii)in the case of a sub-divided measure, are marked with the capacity they are intended respectively to indicate; and

(d)any name or trade mark marked on the measure—

(i)is in lettering which is smaller than the marking of its nominal capacity, and

(ii)is so marked as not to cause confusion with the marking of the nominal capacity.

(6) No graduated or sub-divided measure shall be stamped unless it is made of translucent or transparent material.

(7) For the purposes of paragraph (5)(a) above, the capacity of a measure—

(a)shall be marked,—

(i)before 1st October 1995, in full in gallons, quarts, pints, gills, fluid ounces, litres, centilitres or millilitres, and

(ii)on and after that date in full in pints, litres, centilitres or millilitres,

or by the appropriate abbreviation or symbol in accordance with regulation 2(2) above; and

(b)may be accompanied by a supplementary indication F13... of quantity,—

(i)in the case of a measure marked in gallons, quarts, pints, gills, fluid ounces, expressed in litres, centilitres or millilitres, or

(ii)in the case of a measure marked in litres, centilitres or millilitres, expressed in full in gallons, quarts, pints, gills, fluid ounces,

or by the appropriate abbreviation or symbol in accordance with regulation 2(2) above.

Marking of scale marks on graduated or sub-divided measuresE+W+S

17.—(1) The scale marks of a graduated or sub-divided measure shall be marked with their purported values—

(a)in the case of a metric measure, either in metric units alone or in both metric and imperial units;

(b)in the case of an imperial measure, either in imperial units alone or in both imperial and metric units; and

(c)in the case of a measure which is both a metric and imperial measure, in both metric and imperial units.

(2) In this regulation—

“scale mark” does not include the mark of the nominal capacity; and

“metric measure”, “imperial measure” and “metric and imperial measure” mean, respectively, a measure the nominal capacity of which is given in metric units only, in imperial units only or in both metric and imperial units.

Commencement Information

I17Reg. 17 in force at 10.4.1995, see reg. 1(1)

Obliteration of stampsE+W+S

18.—(1) Subject to paragraphs (2) and (3) below, an inspector shall obliterate the stamp on any capacity measure which—

(a)fails upon testing to fall within the prescribed limits of error; or

(b)fails to comply with any other appropriate requirement of these Regulations.

(2) Where any measure is found not to comply with the requirements of these Regulations only because it falls outside the prescribed limits of error, an inspector may, if he considers the measure can be brought within those limits, instead of immediately obliterating the stamp pursuant to paragraph (1) above, serve upon the person in possession of the measure a notice requiring him to ensure that the measure is brought within those limits before the expiry of 28 days or such shorter time as may be specified in the notice.

(3) If a notice given under paragraph (2) above is not complied with within the period specified in it, the inspector shall obliterate the stamp on the measure to which the notice relates.

(4) An inspector shall obliterate the stamp on any capacity measure which has been the subject of any adjustment, alteration, addition, damage or repair which could, in the opinion of the inspector, have affected its compliance with the appropriate requirements of these Regulations.

Commencement Information

I18Reg. 18 in force at 10.4.1995, see reg. 1(1)

PART VE+W+STESTING EQUIPMENT—PERISTALTIC PUMP DISPENSERS

Peristaltic pump dispensersE+W+S

19.  The Weights and Measures (Local and Working Standard Capacity Measures and Testing Equipment) Regulations 1990(12) are hereby amended,—

(a)in regulation 2(1), by the insertion after the definition of “multifiller” of the following definition—

“peristaltic pump dispenser” means a device, operating on the peristaltic principle, designed to deliver a known quantity of water for the testing of dispensing measures for pharmaceutical purposes;;

(b)in Part III, by the insertion after regulation 18 of the following regulation—

Peristaltic pump dispensers

18A.(1) A peristaltic pump dispenser shall have been tested within 6 months before use at the minimum, at the maximum and at five intermediate delivered volumes suitable for the purpose for which it is to be used.

(2) A peristaltic pump dispenser shall be tested by weighing the water delivered by a suitable weighing machine and determining the delivered volume from the weight so ascertained.

(3) The error on a peristaltic pump dispenser shall not exceed the limits of error shown in Schedule 2 to these Regulations.; and

(c)in Schedule 2, by the insertion at the end of the following table—

Peristaltic pump dispensers

Delivered volumeLimit of error
millilitresmillilitres
10.04
20.04
30.05
40.05
50.06
60.07
70.07
80.08
90.08
100.08
150.10
200.12
250.12
300.13
350.13
400.14
450.14
500.15
600.16
700.17
750.17
800.18
900.20
1000.20
1250.25
1500.30
1750.35
2000.40
2250.40
2500.40
3000.42
3500.42
4000.45
4500.45
5000.50
10001.00.

Commencement Information

I19Reg. 19 in force at 10.4.1995, see reg. 1(1)

Jonathan Evans

Parliamentary Under-Secretary of State,

Department of Trade and Industry

Regulation 1(2)

SCHEDULE 1E+W+SREVOCATIONS

Commencement Information

I20Sch. 1 in force at 10.4.1995, see reg. 1(1)

Regulation revokedReferenceExtent of revocation
The Weights and Measures Regulations 1963S.I. 1963/1710Regulation 1(1)(b) and (c) and (2)(f), regulation 3, regulation 5(1)(b)(i) and (vii), regulation 6(2)(b) to (d), Parts III and IV and Schedule 1, Part II
The Weights and Measures (Amendment) Regulation 1970S.I. 1970/1711The whole Regulations so far as unrevoked
The Weights and Measures (Amendment) Regulations 1974S.I. 1974/1326The whole Regulations

Regulation 15

SCHEDULE 2E+W+SPRESCRIBED LIMITS OF ERROR FOR CAPACITY MEASURES OTHER THAN DISPENSING MEASURES FOR PHARMACEUTICAL PURPOSES

Commencement Information

I21Sch. 2 in force at 10.4.1995, see reg. 1(1)

Normal CapacityLimits for error
ImperialMetricLine measure, in excess and in deficiencyBrim measure, in excess only
(1)(2)(3)(4)
*

for measuring intoxicating liquor only.

Notes:

1.

The limit of error in relation to any scale mark on a sub-divided or graduated measure shall be that specified for a measure of nominal capacity equivalent to the amount which the scale mark is intended to denote, or where the nominal capacity equivalent to the amount does not appear in this Schedule it shall be calculated by interpolation.

2.

On and after 1st October 1995—

(a)

the foregoing table shall have effect with the omission in column 1 of the references to 5, 4 or 3 gal, 2 gal, 1 gal, [F14½ gal,] 1 qt, 8 fl oz, 6 fl oz, 1 gill, 4 fl oz, ½ gill, ⅖, ⅓ gill, ¼, ⅕ gill and ⅙ gill; and

(b)

references to imperial measures shall be to their use for measuring beer and cider only.

5, 4 or 3 gal20 l100 ml200 ml
2 gal, 16 pt10 l50 ml100 ml
1 gal, 8 pt5 l25 ml50 ml
½ gal, 4 pt2.5 or 2 l12 ml24 ml
1 qt, 2 pt1 l10 ml20 ml
1 pt500 ml5 ml10 ml
½ pt250 ml4 ml8 ml
8 fl oz or ⅓ pt200 ml4 ml8 ml
6 fl oz175 ml *3.5 ml7 ml
1 gill150 ml *3 ml6 ml
4 fl oz125 ml *2.5 ml5 ml
½ gill [F15100 ml, 70 ml*]2 ml4 ml
⅖, ⅓ gill50 ml2 ml4 ml
¼, ⅕ gill25 ml, 35 ml *2 ml4 ml
⅙ gill20 ml2 ml4 ml
10 ml1 ml2 ml
4 ml0.5 ml1 ml
2 ml0.2 ml0.4 ml
1 ml0.1 ml0.2 ml

Explanatory Note

(This note is not part of the Regulations)

These Regulations prescribe, for the purposes of section 11(1) of the Weights and Measures Act 1985 (“the Act”), certain dry and liquid capacity measures for use for trade. The Regulations replace Parts III and IV of the Weights and Measures Regulations 1963 and cover all capacity measures other than—

(i)those for the purposes of measuring and serving intoxicating liquor for consumption on the premises at which it is sold, to which the Capacity Serving Measures (Intoxicating Liquor) Regulations 1988 apply, or

(ii)those for use only for making up or checking packages (in accordance with section 49(1) and (2)(a) of the Act), which are specified in paragraph 4 of Schedule 4 to the Weights and Measures (Packaged Goods) Regulations 1986.

The Regulations apply to dispensing measures for pharmaceutical purposes (formerly called apothecaries' measures).

The effect of prescription is to make it unlawful to use these capacity measures for trade purposes unless they have been tested, passed as fit for such use and stamped by an inspector of weights and measures. The Regulations make simplified provision about—

(a)the materials and principles of construction of capacity measures (regulations 4 to 6);

(b)their purpose and manner of use (regulation 7);

(c)their testing for conformity with the nominal capacity of the whole measure and those of its subdivisions, within certain prescribed limits of error (regulations 8 to 14);

(d)their being passed as fit for use for trade and stamped, and the obliteration of stamps (regulations 15 to 17).

The Regulations make the following changes of substance—

(a)a requirement has been introduced to ensure that a buyer of intoxicating liquor, which is transferred from a capacity measure to another container, should have a clear and unobstructed view of the measurement and the transfer (regulation 7(c));

(b)provision is made for testing based on the results of testing a group of measures of between 500 and 150,000 in number (regulation 12);

(c)to avoid duplicate testing of capacity measures imported from other member States of the European Communities or a state of the European Economic Area, by allowing weights and measures inspectors testing the fitness of such measures for use for trade to accept test reports and results from approved bodies in those States (regulations 13 and 16);

(d)dispensing measures for pharmaceutical purposes are now largely dealt with by British Standards (BS) and the relevant BS is referred to in relation to their constructional requirements (regulation 6(2)) and limits of error (regulation 15);

(e)the permissible limits of error are amended and are now in excess and in deficiency (formerly in excess only) (regulation 15 and Schedule 2); and

(f)the requirements relating to the placing of the line on line measures are amended and, on and after 1st October 1995, the only imperial unit which may be marked is the pint (regulation 16(5) and (7)).

The Regulations also amend the Weights and Measures (Local and Working Standard Capacity Measures and Testing Equipment) Regulations 1990 by the inclusion of provisions about the use of peristaltic pump dispensers for the testing of dispensing measures for pharmaceutical purposes.

Copies of British Standards (see regulations 2(1), 6(2), 11, 12, 13, 15 and 16) can be obtained from any of the sales outlets operated by the British Standards Institution (BSI), or by post from the BSI at Linford Wood, Milton Keynes, MK14 6LE.

A Compliance Cost Assessment of the impact that these Regulations will have on business will be available in the libraries of the Houses of Parliament once the Regulations, having been made, are laid before Parliament and from the National Weights and Measures Laboratory, Stanton Avenue, Teddington, Middlesex, TW11 0JZ.

(1)

1985 c. 72; section 94(1) contains a definition of “prescribed”.

(2)

ISBN No. 0 580 12515 7, published by the British Standards Institution in April 1952, as amended in February 1982.

(3)

ISBN No. 0 580 15701 6, published by the British Standards Institution in April 1953, as amended in January 1969 and January 1987.

(4)

ISBN No. 0 580 195732 2, published by the British Standards Institution on 30th March 1972, as amended in May 1991.

(5)

ISBN No. 0 580 22581 X, published by the British Standards Institution on 15th November 1993.

(6)

ISBN No. 0 580 15076 3, published by the British Standards Institution on 28th February 1986.

(7)

See S.I. 1968/1615.

(8)

S.I. 1986/1685.

(9)

S.I. 1988/120, to which there are amendments not relevant to these Regulations.

(10)

S.I. 1986/2049, to which there are amendments not relevant to these Regulations.

(11)

S.I. 1990/2626 as amended by regulation 19 of these Regulations.

(12)

S.I. 1990/2626.

Back to top

Options/Help

Print Options

Close

Legislation is available in different versions:

Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.

Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.

Point in Time: This becomes available after navigating to view revised legislation as it stood at a certain point in time via Advanced Features > Show Timeline of Changes or via a point in time advanced search.

Close

See additional information alongside the content

Geographical Extent: Indicates the geographical area that this provision applies to. For further information see ‘Frequently Asked Questions’.

Show Timeline of Changes: See how this legislation has or could change over time. Turning this feature on will show extra navigation options to go to these specific points in time. Return to the latest available version by using the controls above in the What Version box.

Close

Opening Options

Different options to open legislation in order to view more content on screen at once

Close

More Resources

Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:

  • the original print PDF of the as enacted version that was used for the print copy
  • lists of changes made by and/or affecting this legislation item
  • confers power and blanket amendment details
  • all formats of all associated documents
  • correction slips
  • links to related legislation and further information resources
Close

Timeline of Changes

This timeline shows the different points in time where a change occurred. The dates will coincide with the earliest date on which the change (e.g an insertion, a repeal or a substitution) that was applied came into force. The first date in the timeline will usually be the earliest date when the provision came into force. In some cases the first date is 01/02/1991 (or for Northern Ireland legislation 01/01/2006). This date is our basedate. No versions before this date are available. For further information see the Editorial Practice Guide and Glossary under Help.