Regulation 2
Type of equipment | Net installed power P (in kW) Electric power Pel a in kW Mass of appliance m in kg Cutting width L in cm | Permissible sound power level in dB/1 pW | |
---|---|---|---|
Stage I as from 3 January 2002 | Stage II as from 3 January 2006 | ||
a Pel for welding generators: conventional welding current multiplied by the conventional load voltage for the lowest value of the duty factor given by the manufacturer. Pel for power generators: prime power according to ISO 8528-1:1993, clause 13.3.2. | |||
b For the following types of equipment the figures for Stage I shall continue to apply for Stage II—
| |||
c For single engine mobile cranes the figures for Stage I shall continue to apply until 3rd January 2008. After that date, Stage II figures shall apply. | |||
Compaction machines (vibrating rollers, vibratory plates, vibratory rammers) | P ≤ £ 8 | 108 | 105b |
8 < P ≤ £70 | 109 | 106b | |
P > 70 | 89 + 11 1g P | 86 + 11 1g Pb | |
Tracked dozers, tracked loaders, tracked excavator-loaders | P ≤ 55 | 106 | 103b |
P > 55 | 87 + 11 1g P | 84 + 11 1g Pb | |
Wheeled dozers,wheeled loaders, wheeled excavator-loaders, dumpers, graders, loader-type landfill compactors, combustion-engine driven counterbalanced lift trucks, compaction machines (non-vibrating rollers),paver-finishers, hydraulic power packs | P ≤ 55 | 104 | 101b |
P > 55 | 85 + 11 1g P | 82 + 11 1g Pb | |
Mobile cranes | P ≤ 55 | 104 | 101c |
P > 55 | 85 + 11 1g P | 82 + 11 1g P 101c | |
Excavators, builders' hoists for the transport of goods, construction winches, motor hoes | P ≤ 15 | 96 | 93 |
P > 15 | 83 + 11 1g P | 80 + 11 1g P | |
Hand-held concrete-breakers and picks | m ≤ 15 | 107 | 105 |
15< m < 30 | 94 + 11 1g m | 92 + 11 1g mb | |
m ≥ 30 | 96 + 11 1g m | 94 + 11 1g m | |
Tower cranes | 98 + 1g P | 96 + 1g P | |
Welding and power generators | Pel ≤ 2 | 97 + 1g Pel | 95 + 1g Pel |
2 < Pel ≤ 10 | 98 + 1g Pel | 96 + 1g Pel | |
10 > Pel | 97 + 1g Pel | 95 + 1g Pel | |
Compressors | P ≤ 15 | 99 | 97 |
P > 15 | 97 + 2 1g Pel | 95 + 2 1g Pel | |
Lawnmowers, lawn trimmers/lawn-edge trimmers | L ≤ 50 | 96 | 96 |
50 < L ≤ 70 | 100 | 98 | |
70 < L ≤ 120 | 100 | 100 | |
L > 120 | 105 | 105 | |
The permissible sound power level shall be rounded up or down to the nearest integer number (less than 0.5, use lower number; greater than or equal to 0.5, use higher number). |
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include: