60.—(1) Operating conditions
(a)Range
Dimensions within the range specified by the manufacturer for the instrument.
(b)Minimum dimension
The lower limit of the minimum dimension for all values of the scale interval is given in Table 23.
Scale interval (d) | Minimum dimension (min) (lower limit) |
---|---|
d ≤ 2 cm | 10 d |
2 cm < d ≤ 10 cm | 20 d |
10 cm < d | 50 d |
(c)Speed of the product
The speed must be within the range specified by the manufacturer for the instrument.
(2) MPE
Instrument—
The MPE is ± 1.0 d.
Latest Available (revised):The latest available updated version of the legislation incorporating changes made by subsequent legislation and applied by our editorial team. Changes we have not yet applied to the text, can be found in the ‘Changes to Legislation’ area.
Original (As Enacted or Made): The original version of the legislation as it stood when it was enacted or made. No changes have been applied to the text.
Explanatory Memorandum sets out a brief statement of the purpose of a Statutory Instrument and provides information about its policy objective and policy implications. They aim to make the Statutory Instrument accessible to readers who are not legally qualified and accompany any Statutory Instrument or Draft Statutory Instrument laid before Parliament from June 2004 onwards.
Access essential accompanying documents and information for this legislation item from this tab. Dependent on the legislation item being viewed this may include:
Use this menu to access essential accompanying documents and information for this legislation item. Dependent on the legislation item being viewed this may include:
Click 'View More' or select 'More Resources' tab for additional information including: